Manual Broan P408ICAT

16 pages 1.62 mb
Download

Go to site of 16

Summary
  • Broan P408ICAT - page 1

    E64000 SERIES INTENDED FOR DOMESTIC COOKING ONL Y INST ALLER: LEA VE THIS MANU AL WITH HOMEO WNER. HOMEO WNER: USE AND CARE INFORMA TION ON P A GES 13 AND 14. Broan-NuT one LLC; Har tf ord, Wisconsin www .broan.com 800-558-1711 Broan-NuT one Canada; Mississauga, Ontario www .broan.ca 877-896-1119 REGISTER Y OUR PRODUCT ON LINE A T : www .broan.com/ ...

  • Broan P408ICAT - page 2

    W ARNING W ARNING - 2 - T O REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJUR Y TO PERSONS, OBSER VE THE FOLLO WING: 1. Use this unit only in the manner intended by the manuf acturer . If you hav e questions, contact the manuf acturer at the address or telephone number listed in the warranty . 2. Bef ore ser vicing or cleaning unit, switch po wer of ...

  • Broan P408ICAT - page 3

    HL0097 - 3 - RMP SERIES BA CKSPLASH (S T AINLESS S TEEL W ALL CO VERING WITH W ARMING SHEL VES . O PTIONAL .) 8” R OUND A DJUST ABLE E LBOW M ODEL 412 T RANSITION (3¼” X 10” TO 7”) A DAPTER /D AMPER 3¼’ ’ X 10’ ’ ( SUPPLIED WITH SINGLE BLOWER HOOD ) A DAPTER 4½” X 18½” ( SUPPLIED WITH DOUBLE BLOWER HOOD ) S T AND ARD D UCT ( ...

  • Broan P408ICAT - page 4

    - 4 - HL009 8 RMP SERIES BA CKSPLASH (S T AINLESS S TEEL W ALL CO VERING WITH W ARMING SHEL VES . O PTIONAL ) E64000 SERIES HOOD - E64000 SERIES RANGE HOOD SYSTEM - IN-LINE AND EXTERIOR BLO WERS 332KR IN - LINE AND E XTERIOR B LOWER R OUGH - IN K IT ( SUPPLIED WITH HOOD ) M ODEL 418 10” R OUND A DJUST ABLE E LBOW M ODEL HLB3 (280 CFM ) I N - LINE ...

  • Broan P408ICAT - page 5

    - 5 - 1. SELECT BLOWER OPTION AND INST ALLA TION TYPE 1.2 D UCTED I NST ALLA TION The Broan Elite E64000 Series range hood includes many configurations: hood with single or double internal blow ers (included with the hood), or hood using e xter nal blo wers. For hood using e xter nal blo wers, the Broan Elite E64000 Series must be installed with in ...

  • Broan P408ICAT - page 6

    - 6 - 2. PREP ARE THE INST ALLA TION Make sure that the f ollowing items are included: - Range hood - Accessories: • Baffle filters • Baffle filters handles (located inside the hood) • 3¼” x 10” adapter/damper (located inside inter nal single blo wer hood) • 4½” x 18½” adapter (screwed inside internal double b lower hood) • In- ...

  • Broan P408ICAT - page 7

    - 7 - 2. PREP ARE THE INST ALLA TION (CONT’D) Cut-out the openings f or duct ( A ) and power cab le ( B ), in cabinet or wall, according to the direction of discharge chosen. See figures below . NO TE: F or all inter nal blo wer hoods, the cut-out opening f or house wiring can be made in cabinet bottom OR wall, no matter the discharge chosen (ver ...

  • Broan P408ICAT - page 8

    - 8 - 4. REMOVE FIL T ERS AND GREASE DRIP RAIL A. Remov e tape on filters. Remov e filters from hood and set aside. NO TE: It is recommended to star t with the center one(s). B. Remov e tape on grease drip rail ( 1 ). Lift out grease drip rail and set aside. HD0240 1 5. REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONL Y) Remov e both screws retaining ...

  • Broan P408ICAT - page 9

    - 9 - 6. CHOOSE THE OPENING(S) (INTERNAL BLOWER HOODS ONL Y) Remov e the knock out for the chosen opening(s) (horizontal at the bac k of the hood or vertical on top). See illustrations below . V ERTICAL DISCHARGE H ORIZONT AL DISCHARGE NO TE: F or ducted installation only . 1 2 3 HR0021 1 2 3 Punch out the appropriate electr ical knoc kout hole on ...

  • Broan P408ICAT - page 10

    - 10 - 7. HORIZONT AL DISCHARGE INST ALLA TION ( INTERNAL BLOWER(S) ONL Y) HD0271 Flip the blo wer and engage its flange in the back w all retaining brac ket. Using a 5/16” sock et and the screws pre viously remov ed, secure the blo wer to the hood. HD0272 8. INST ALL THE ADAPTER AND THE TRANSITION (IF NEED BE) (INTERNAL BLOWER HOOD ONL Y) Using ...

  • Broan P408ICAT - page 11

    - 11 - 10. INST ALL THE HOOD (ALL BLOWERS) HD0265 A B A B B INTERNAL BLO WER: Run power cab le to installation location. Place the hood in its location. Mar k the position of the scre ws (smaller par t of the ke y holes [ A ]) with a pen. Remov e the hood and install the (4) 1/2” doub le thread screws at marked positions , leaving a 1/8” gap. R ...

  • Broan P408ICAT - page 12

    - 12 - 13. INST ALL LIGHT BULBS This hood must use 120 V , 50 W , MR16 with GU10 base or P AR16 with GU10 base, shielded halogen lamps (not included). W ARNING In order to pre vent the risk of personal injury , do not install a lamp identified f or use only in enc losed fixtures. ! W ARNING In order to pre vent the risk of personal injury , the hal ...

  • Broan P408ICAT - page 13

    - 13 - 15. USE AND CARE Baffle Filters The baffle filters should be cleaned frequently . Use a war m detergent solution. W ash more often if your cooking style generates greater grease—lik e fr ying foods or w ok cooking. Remov e baffle filters by pushing them to wards the back of hood and rotating filters do wnward. Baffle filters are dishwasher ...

  • Broan P408ICAT - page 14

    - 14 - 16. OPERA TION (CONT’D) HC00 3 5 1) Halogen light knob 2) Blower operation indicator 3) ON/OFF blow er switch 4) Blower speed control knob 2 3 1 4 HC00 3 4 A) Halogen light knob B) Blower speed control knob A B COOKT OP LIGHTING (HALOGEN) A rotar y 3-position knob ( 1 ) controls the halogen lights (OFF - low intensity - high intensity). BL ...

  • Broan P408ICAT - page 15

    - 15 - 18. WIRING DIAGRAMS Broan Elite E64000 Series Internal blower hoods Broan Elite E64000 Series Exterior or In-Line blower hoods LINE NEUTRAL GROUND 120 V AC WHT M BRN BLU RED BLK M BRN BLU RED BLK WHT S PEED CONTROL H S THERMO S TAT BLU BLK BLK BLU BLK YEL WHT WHT WHT WHT WHT BLK BLK YEL YEL BLK ORA NEON LAMP ORA LAMP S WITCH L 1- 3 2 FAN S W ...

  • Broan P408ICAT - page 16

    - 16 - 19. SER VICE P ARTS HL0104 Broan Elite E64000 Series Internal blower hoods Broan Elite E64000 Series Exterior or In-Line blower hoods 6 7 14 17 * N OT SHO WN . K EY NO . P ART NO . D ESCRIPTION Q TY . ( H OOD WIDTH ) 30” 36” 42” 48” 2 SV06750 B ROAN E LITE L OGO 1 1 1 1 3 SV16569 L AMP S HELL , S OCKET & T RIM A SS ’ Y 2 2 3 3 ...

Manufacturer Broan Category Ventilation Hood

Documents that we receive from a manufacturer of a Broan P408ICAT can be divided into several groups. They are, among others:
- Broan technical drawings
- P408ICAT manuals
- Broan product data sheets
- information booklets
- or energy labels Broan P408ICAT
All of them are important, but the most important information from the point of view of use of the device are in the user manual Broan P408ICAT.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Broan P408ICAT, service manual, brief instructions and user manuals Broan P408ICAT. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Broan P408ICAT.

Similar manuals

A complete manual for the device Broan P408ICAT, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Broan P408ICAT by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Broan P408ICAT.

A complete Broan manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Broan P408ICAT - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Broan P408ICAT, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Broan P408ICAT, that we can find in the current document
3. Tips how to use the basic functions of the device Broan P408ICAT - which should help us in our first steps of using Broan P408ICAT
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Broan P408ICAT
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Broan P408ICAT in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Broan P408ICAT?

Use the form below

If you did not solve your problem by using a manual Broan P408ICAT, ask a question using the form below. If a user had a similar problem with Broan P408ICAT it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)