Manual Royal G31

22 pages 0.3 mb
Download

Go to site of 22

Summary
  • Royal G31 - page 1

    0102 095 50261 6/,0/,1(67$1'$5' USERS INSTRUCTIONS THIS CAT I 3P APPLIANCE IS FOR USE ON PROPANE GAS G31 AT A SUPPLY PRESSURE OF 37 mbar IN GB & IE HAND THESE INSTRUCTIONS TO THE USER DESCRI PTI ON ...

  • Royal G31 - page 2

    This Royal Cozy Fires Decorative Fuel Effect gas fire has been developed to give a realist ic coal burning appearance with the instant control and convenience of g as. The fire has been constructed to enable it to be installed into applications where the warmth and comfort of an open fire and hig h radiant heat is required. This appliance is intend ...

  • Royal G31 - page 3

    One ty pe of fire front and fret sugg ested is shown in Fig 1, this has a perforated fret to allow air to be drawn into the coal bed for combustion and over the controls for cooling purposes. I f other fronts and frets are to be used they must have a minimum open area in the fret of 20 sq. cms and 60 sq. cms in the front. See Fig 1 This appliance i ...

  • Royal G31 - page 4

    It is very important that the coals and the coal bed components are laid as shown no extra coals or material may be used. I f any of the items become lost or damaged, replacements must be obtained before further use of th e appliance. Relaying the Coal Bed Fit the coal support shelf (ensuring that the front edge sits behind the three tabs) and the ...

  • Royal G31 - page 5

    Page 4 Page 5 ...

  • Royal G31 - page 6

    REGI STRATI ON RECORD Purchaser’ s Name__________________________________________________ and Address __________________________________________________ __________________________________________________ Supplier’ s Name __________________________________________________ and Address __________________________________________________ ___________ ...

  • Royal G31 - page 7

    0102 095 50251 6/,0/,1(67$1'$5' INSTALLATION and SERVICING INSTRUCTIONS THIS CAT I 3P APPLIANCE IS FOR USE ON PROPANE GAS G31 AT A SUPPLY PRESSURE OF 37 mbar IN GB & IE HAND THESE INSTRUCTIONS TO THE USER ...

  • Royal G31 - page 8

    DESCRIPTION This Roy al Cozy Fi res Decorative Fuel Effect gas fire has been developed to give a realisti c coal burning appearance with the instant control and convenience of gas. The fire has been constructed to enable it to be installed into applications where the warmth and comfort of an open fire and high radiant heat is required. This applian ...

  • Royal G31 - page 9

    Installation Regulation and Requirements The appliance must be installed by a competent person in accordance with the current Gas S afety (I nstall atio n and Use) Regulations 1994 (as amended) or the rules in force and in accordance with the manufacturers instructions, failure to do so could lead to prosecution. The following ar e the re leva nt C ...

  • Royal G31 - page 10

    Fire Surround and Opening Requirements Check that the chimney and flue structure are sound and conform to the following flue requirements: a) A conventional brick or stone chimney with a minimum effective cross sectional dimension of 225x225mm. A lined flue with a minimum diameter of 175mm having a chairbrick and throat forming lintel conforming to ...

  • Royal G31 - page 11

    Installation of the Appliance Check tha t the chimney conforms to the required specific ations as previously stated. Examine the condition and carry out any remedial work as necessary , if the flue has been used for solid fuel it should be swept and a smoke test carried out to check that sat isfactory smoke clearance has been established. If all th ...

  • Royal G31 - page 12

    Installing the Appliance in Position When the ga s supply pipe has been laid to the position required, the surround should be fitted and sealed to the chimney correctly. This is to prevent any seepage of flue products or to prevent any ingress of air into the flue from any where other than the flue outlet of the fire. The easier method of installat ...

  • Royal G31 - page 13

    To check the gas pressure at the appliance, allow the coals and the coal bed to cool and turn off the g as supply at the isolating cock. Remove the hexagon headed screw and connect a manometer to the pressure test point, turn on the g as and ignite the fire, allow to heat up and check that the gas pressure is 37 mbar +/ - 1 mbar - any appreciable d ...

  • Royal G31 - page 14

    Maintenan ce and S ervicing GENERAL A. REMOVAL OF DEBRIS OR SOOT DEPOSITS Allow the appliance to cool sufficiently before removing all of the coals and firebed components for cleaning purposes. Once all the cerami cs are removed from the firebed check that no debris is locat ed in the burner slots (both front and rear). If any debris is present it ...

  • Royal G31 - page 15

    Page 9 ...

  • Royal G31 - page 16

    Page 10 ...

  • Royal G31 - page 17

    Page 11 ...

  • Royal G31 - page 18

    ...

  • Royal G31 - page 19

    Page 12 ...

  • Royal G31 - page 20

    Page 13 ...

  • Royal G31 - page 21

    Page 14 No Figures 13 & 15 On this page ...

  • Royal G31 - page 22

    Registration Record Purchasers Name ....................................................................................... and Address ....................................................................................... ....................................................................................... ...................................... ...

Manufacturer Royal Category Indoor Fireplace

Documents that we receive from a manufacturer of a Royal G31 can be divided into several groups. They are, among others:
- Royal technical drawings
- G31 manuals
- Royal product data sheets
- information booklets
- or energy labels Royal G31
All of them are important, but the most important information from the point of view of use of the device are in the user manual Royal G31.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Royal G31, service manual, brief instructions and user manuals Royal G31. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Royal G31.

Similar manuals

A complete manual for the device Royal G31, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Royal G31 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Royal G31.

A complete Royal manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Royal G31 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Royal G31, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Royal G31, that we can find in the current document
3. Tips how to use the basic functions of the device Royal G31 - which should help us in our first steps of using Royal G31
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Royal G31
5. FAQ - Frequently Asked Questions