    User Manual ISA Audio Power Amplifiers ISA Series Installed Sound Amplifiers TD-000093-00 rev .C *TD-000093-00* n ISA 300T n ISA 500T n ISA 800T n ISA 280 n ISA 450 n ISA 750 ...

  • QSC Audio ISA 300T - page 2

    CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER. NO USER- SERVICEABLE P ARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. FCC INTERFERENCE ST A TEMENT NOTE: This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to pro ...

  • QSC Audio ISA 300T - page 3

    INTRODUCTION: ISA Series Overview .......................................................................................4 Front Panel Illustration .........................................................................................4 Rear Panel Illustrations ...................................................................................... ...

  • QSC Audio ISA 300T - page 4

    FRONT PANEL (all models) Thank you for the purchase of your new ISA amplifier . T o get the most out of your amplifier , review this manual carefully . The installation, connection and operation sections provide useful guidelines to get you up and running quickly and correctly . The QSC shipping box should contain: 1- The amplifier 2- This user man ...

  • QSC Audio ISA 300T - page 5

    1. Gain Controls 2. T erminal Block Inputs 3. DataPort V2 Connector 4 . XLR Inputs ...

  • QSC Audio ISA 300T - page 6

    The front panel of ISA series amplifiers is tailored for installed sound. The power switch is the only front panel control; gain controls are located on the rear panel to minimize control tampering. LED indicators are provided for power , input signal and to warn of clipping. If the POWER LED fails to illuminate when the switch is in the ON positio ...

  • QSC Audio ISA 300T - page 7

    FEA TURES & SETUP- LED INDICA TORS CLIP : red LED that illuminates when the amplifier clips. Normal indication: illumination briefly at extreme output power peaks. Occasional clipping (once briefly every few seconds) when operation at high power levels is normal. At power -on, the clip LEDs may briefly flash; this is normal. Continuous operatio ...

  • QSC Audio ISA 300T - page 8

    FEA TURES & SETUP- GAIN CONTROLS & INPUT JACKS GAIN CONTROLS- The Gain controls are located on the rear panel to minimize control tampering after installation. When viewing the amplifier from the rear , they are on the left end, top and bottom, as shown in the illustration to the right. The Gain controls are detented (11 steps) for repeatab ...

  • QSC Audio ISA 300T - page 9

    DA T APORT V2- What It Is- The DataPort V2 is used for connection to optional QSC DataPort accessories. DataPort accessory devices can provide remote cinema monitoring, DSP , filter and crossover functions. The “ V2 ” DataPort connection is a “ version-2 ” of QSC ’ s original DataPort. It has a reduced feature set from the original, while ...

  • QSC Audio ISA 300T - page 10

    FEA TURES & SETUP- STEREO & P ARALLEL OPERA TING MODES P ARALLEL: The channel 1 and channel 2 inputs are connected together , applying a single input signal to both channels of the amplifier . A signal into any input jack will drive both channels. Each channel's low frequency filtering, clip limiting, and gain control still function in ...

  • QSC Audio ISA 300T - page 11

    FEA TURES & SETUP- STEREO & P ARALLEL MODE DIP SWITCH SETTINGS ISA 280, ISA 450, ISA 750: Refer to the switch setting keys for each mode, to the right. These keys are printed on the amplifier ’ s rear panel for easy reference when you are behind the equipment rack. SETTING THE DIP SWITCHES FOR STEREO OR P ARALLEL MODE- “T” models ISA ...

  • QSC Audio ISA 300T - page 12

    FEA TURES & SETUP- BRIDGE OPERA TING MODE & DIP SWITCH SETTINGS BRIDGE MODE OPERA TION- Note that speaker connection for bridge mono mode is different than other modes. See section on Connections: Outputs for proper bridge mode output connections. ...

  • QSC Audio ISA 300T - page 13

    FEA TURES & SETUP- LOW FREQUENCY FIL TER & DIP SWITCH SETTINGS SETTING THE FIL TER DIP SWITCHES- 1- Set switch #3 and #8 to the on or off position as desired. 2- Select the desired roll-off frequency at switch #2 and #9. 3- If filter off is selected, the frequency selection has no effect. If operating in BRIDGE MODE- 1- When in bridge mode, ...

  • QSC Audio ISA 300T - page 14

    ...

  • QSC Audio ISA 300T - page 15

    FEA TURES & SETUP- CLIP LIMITER & DIP SWITCH SETTINGS CAUTION: Clip limiting reduces extreme overdrive peaks, allowing a higher average signal level without audible distortion. However , increasing the gain with the clip limiter engaged, until clipping is again audible, can double the average output power . Be careful not to exceed the powe ...

  • QSC Audio ISA 300T - page 16

    INST ALLA TION: RACK MOUNTING AND MOUNTING DIMENSIONS Securing the Front Ears to the Rack Rails Use four screws and washers when mounting the ISA amplifier to the front rails. Support the weight of the amplifier while securing it to the rails to avoid bending or distorting the front rack mount ears. ISA Rack Mounting Method 2- The amplifier is firs ...

  • QSC Audio ISA 300T - page 17

    INST ALLA TION: COOLING REQUIREMENTS & AC MAINS FAN COOLING- Keep the front and rear vents clear to allow full air flow . Make sure that plenty of cool air can enter the rack, especially if there are other units which exhaust hot air into it. Connecting to the wrong line voltage is dangerous and may damage the amplifier or constitute the risk o ...

  • QSC Audio ISA 300T - page 18

    Unbalanced inputs : Connect the conductors to the connector as shown. Make sure that the unused side of the balanced input is connected to ground, as shown. XLR: unbalanced connection T erminal block: unbal anced connections XLR : balanced connection T erminal block: bal anced connections CONNECTIONS: INPUTS- XLR & TERMINAL BLOCK jumper shield ...

  • QSC Audio ISA 300T - page 19

    CONNECTIONS: INPUTS- DA T APORT V2 The ISA series of amplifiers come with a DataPort V2 connector that may be used for connecting to accessory QSC DataPort devices. The V2 (or version 2) DataPort does not have the full capability of the standard DataPort. The DataPort V2 must be connected to a QSC DataPort product with a QSC DataPort cable; similar ...

  • QSC Audio ISA 300T - page 20

    CONNECTIONS: OUTPUTS- USING THE SCREW TERMINAL CONNECTIONS GENERAL- The screw terminal output connections are protected by a hinged plastic cover . T o make connections to the screw terminals, you will need to swing the cover door open. Gently pry the cover with your finger tips on the side that has the wire openings. After the door is open, loosen ...

  • QSC Audio ISA 300T - page 21

    CONNECTIONS: OUTPUTS- DIRECT LOW IMPEDANCE (LO-Z) BRIDGE MODE PRECAUTIONS: Do Not Use 2 ohm Loads in Bridge Mono Mode! 4 ohms is the minimum impedance for bridge mono operation! This mode puts a high demand on the amplifier and speaker . Excessive clipping may cause protective muting or speaker damage. Ensure the speaker has a sufficient power rati ...

  • QSC Audio ISA 300T - page 22

    CONNECTIONS: OUTPUTS- DISTRIBUTED HIGH IMPEDANCE (HI-Z) , STEREO & P ARALLEL ...

  • QSC Audio ISA 300T - page 23

    CONNECTIONS: OUTPUTS- DISTRIBUTED HIGH IMPEDANCE (HI-Z) , BRIDGE MODE OUTPUT TERMINAL SAFETY WARNING! Do not touch output terminals while amplifier power is on. Make all connections with amplifier turned off. Risk of hazardous energy! ...

  • QSC Audio ISA 300T - page 24

    CONNECTIONS: POWER SHARING BETWEEN HIGH & LOW IMPEDANCE OUTPUTS The ISA 300T , ISA 500T and ISA 800T models are equipped with autotransformer-coupled, high impedance (High-Z) outputs. They are also equipped with low impedance (Low- Z) “ direct ” outputs. The high impedance outputs are not isolated. The unique feature of the “ T ” model ...

  • QSC Audio ISA 300T - page 25

    CONNECTIONS: SECURING OUTPUT WIRING TO CHASSIS ...

  • QSC Audio ISA 300T - page 26

    OPERA TION: AC POWER SWITCH, LED INDICA TORS, GAIN CONTROLS NORMAL OPERA TING LEVELS The amplifier ’ s protective muting system guards against excessive internal temperatures. With normal ventilation and 4 to 8 ohm loads, the amplifier will handle any signal level, including overdrive. Lower load impedances and higher signal levels produce more i ...

  • QSC Audio ISA 300T - page 27

    APPLICA TIONS: GENERAL APPLICA TION INFORMA TION The ISA 280, ISA 450 and ISA 750 amplifiers are optimized for directly driving low impedance loads. Low impedance (Lo-Z) loads are those loads between 2 and 16 ohms. These models are not suitable for driving “ constant voltage ” 70V lines. These low impedance models are referred to collectively a ...

  • QSC Audio ISA 300T - page 28

    APPLICA TIONS: LOW FREQUENCY FIL TERING & DISTRIBUTED OUTPUTS The low frequency filtering is another difference in the characteristics of the “ non-T ” and the “ T ” amplifiers. Because transformers and other magnetic devices are prone to low frequency “ misbehavior ” (called saturation) , the autotransformer equipped “ T ” mode ...

  • QSC Audio ISA 300T - page 29

    100 V olt, two-zone example: The illustration to the right shows a typical two-zone 100 volt system. When using 100 volt speaker loads, make sure that connec- tions to the amplifier are made to the 100 volt output terminals. If using the ISA 300T , 300 watts per channel (zone) can be delivered. Make sure that the total speaker power load on each ch ...

  • QSC Audio ISA 300T - page 30

    APPLICA TIONS: MUL TIPLE LOW IMPEDANCE LOADS IN SERIES (all models) ...

  • QSC Audio ISA 300T - page 31

    APPLICA TIONS: MUL TIPLE LOW IMPEDANCE LOADS IN P ARALLEL (all models) ...

  • QSC Audio ISA 300T - page 32

    32 The DSP-3 Digital Signal Processing Module provides compressor -limiter , multiple parametric filters, high- and low-pass filters, shelf filters, multiple delays, polarity reversal, muting and attenuation. These features and more come packed into a small module that interfaces with the DataPort V2 connector on the rear of your ISA amplifier . No ...

  • QSC Audio ISA 300T - page 33

    • INDICA TION: CLIP LED FLASHING • If the red clip indicator flashes when signal is applied, the amplifier output may be shorted. Check that the speaker cable connec- tions are tight and reliable at both ends. Check the speaker cables for stray strands or breaks in the insulation. T rim off all loose strands of wire and insulate any exposed wir ...

  • QSC Audio ISA 300T - page 34

    PROBLEM: DISTORTED SOUND Magnetic field from power supplies in equipment can induce hum into cabling that is located in the field. If hum is a problem, try relocating cabling so that is away from power supplies, transformers and other magnetic field producing devices. TROUBLESHOOTING: DISTORTION, NO CHANNEL SEP ARA TION, HUM, HISS, FEEDBACK ...

  • QSC Audio ISA 300T - page 35

    SPECIFICA TIONS ISA 280 ISA 450 ISA 750 OUTPUT POWER in watts FTC: 8 ohms per channel (20-20k Hz., 0.1% THD) 185 260 450 4 ohms per channel (20-20k Hz., 0.1% THD) 280 425 650 EIA: 16 ohms (1 kHz., 0.1% THD, 1 channel driven) 100 140 250 8 ohms (1 kHz, 0.1% THD, 1 channel driven) 200 280 475 4 ohms (1 kHz, 0.1% THD, 1 channel driven) 300 500 750 2 o ...

  • QSC Audio ISA 300T - page 36

    SPECIFICA TIONS ISA 280 ISA 450 ISA 750 AMPLIFIER PROTECTION Full short circuit, open circuit, thermal, ultrasonic and RF protection. Stable into reactive or mismatched loads. COOLING Continuously variable speed fan; back-to-front air flow. INDICATORS Front Panel: POWER LED (green), 2 each SIGNAL (green) and CLIP (red) LEDs CONNECTORS Input: (2)XLR ...

  • QSC Audio ISA 300T - page 37

    SPECIFICA TIONS ISA 300T ISA 500T ISA 800T OUTPUT POWER in watts Low Impedance FTC: 8 ohms per channel (20-20k Hz., 0.1% THD) 185 260 450 4 ohms per channel (20-20k Hz., 0.1% THD) 280 425 650 Low Impedance EIA: 16 ohms (1 kHz., 0.1% THD, 1 channel driven) 100 140 250 8 ohms (1 kHz, 0.1% THD, 1 channel driven) 200 280 475 4 ohms (1 kHz, 0.1% THD, 1 ...

  • QSC Audio ISA 300T - page 38

    SPECIFICA TIONS ISA 300T ISA 500T ISA 800T AMPLIFIER PROTECTION Full short circuit, open circuit, thermal, ultrasonic and RF protection. Stable into reactive or mismatched loads. COOLING Continuously variable speed fan; back-to-front air flow. INDICATORS Front Panel: POWER LED (green), 2 each SIGNAL (green) and CLIP (red) LEDs CONNECTORS Input: (2) ...

  • QSC Audio ISA 300T - page 39

    Disclaimer QSC Audio Products, Inc. is not liable for any damage to speakers, amplifiers, or any other equipment that is caused by negligence or improper installation and/or use of the ISA amplifier . Product Warranty QSC guarantees the ISA amplifier to be free from defective material and/or workmanship for a period of three years from the date of ...

  • QSC Audio ISA 300T - page 40

    QSC Audio Products, Inc. 1675 MacArthur Boulevard Costa Mesa, California 92626 USA “ QSC ” and the QSC logo are registered with the U.S. Patent and T rademark Office. ©2000 QSC Audio Products, Inc. ...

Manufacturer QSC Audio Category Stereo Amplifier

Documents that we receive from a manufacturer of a QSC Audio ISA 300T can be divided into several groups. They are, among others:
- QSC Audio technical drawings
- ISA 300T manuals
- QSC Audio product data sheets
- information booklets
- or energy labels QSC Audio ISA 300T
All of them are important, but the most important information from the point of view of use of the device are in the user manual QSC Audio ISA 300T.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals QSC Audio ISA 300T, service manual, brief instructions and user manuals QSC Audio ISA 300T. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product QSC Audio ISA 300T.

Similar manuals

A complete manual for the device QSC Audio ISA 300T, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use QSC Audio ISA 300T by users. Manuals are usually written by a technical writer, but in a language understandable to all users of QSC Audio ISA 300T.

A complete QSC Audio manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual QSC Audio ISA 300T - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the QSC Audio ISA 300T, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the QSC Audio ISA 300T, that we can find in the current document
3. Tips how to use the basic functions of the device QSC Audio ISA 300T - which should help us in our first steps of using QSC Audio ISA 300T
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with QSC Audio ISA 300T
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of QSC Audio ISA 300T in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning QSC Audio ISA 300T?

Use the form below

If you did not solve your problem by using a manual QSC Audio ISA 300T, ask a question using the form below. If a user had a similar problem with QSC Audio ISA 300T it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)