    E6581373 TOSVERT VF-FS1 series L ON W ORKS ® option unit Communication Func tion Manual NOTICE 1. Make sure that this ins truction m anual is delivered to the end user of L ON W ORKS option unit. 2. Read this manual befor e installing or operating the L ON W ORKS option unit. Keep it in a safe plac e for r eferenc e. 3. All inform ation contained ...

  • Toshiba TOSVERT VF-FS1 Series - page 2

    E6581373 - 1 - Introduction Thank you for purchasing the “ L ON W ORKS option unit” f or TO SVERT VF- FS1 series inverter. Before us ing L ON W ORKS option unit, car efully read this function m anual in order to com pletely and cor rectly utilize its excellent perf orm ance. After r eading this func tion manual, pleas e keep it handy for f utur ...

  • Toshiba TOSVERT VF-FS1 Series - page 3

    E6581373 - 2 - Table of Contents 1. Scope ........................................................................................................................ ..........................4 1.1. Overview ................................................................................................................... .................4 1.2. Appli ...

  • Toshiba TOSVERT VF-FS1 Series - page 4

    E6581373 - 3 - 6.5.8. nviEme rgOverride (Em ergency stop) ............................................................................. 25 6.5.9. nviParamCm d (Param eter access ) .................................................................................26 6.6. Output network variables......................................................... ...

  • Toshiba TOSVERT VF-FS1 Series - page 5

    E6581373 - 4 - 1. Scope 1.1. Overv iew L ON W ORKS technology is a network contr ol system c oncept developed by Echelon Corporation, L ON W ORKS network provides Local O perating N etwork that is super ior in the distributed c ontrol. it is featured by peer to peer com m unication between the L ON W ORKS nodes. T his L ON W ORKS option is equipped ...

  • Toshiba TOSVERT VF-FS1 Series - page 6

    E6581373 - 5 - 2. Names and functions of main par t s 2.1. Outline view The drawings below show nam es of m ain parts. Refer to each instr uction m anual for ins talling and wiring. 2.1.1. LIU006Z 2.1.2. LIU007Z (for VF-FS1) *1: Refer to f ollowing section. *2: Refer to LIU007Z instruction m anual (E6581371) for details. Service LED *1 Status LED * ...

  • Toshiba TOSVERT VF-FS1 Series - page 7

    E6581373 - 6 - 2.2. Diagnosti cs 2.2.1. Service LED Service LED indicates the node condition. 1 2 3 4 5 6 1 345 2 LED OFF LED ON Power ON Time (second) Continues to be OFF Continues to be ON Momentarily OFF t hen continues to be ON Repeats ON and OFF Repeats ON and OFF Continues to be OFF No Phenomenon Problem & Solutions 1 Although the inverte ...

  • Toshiba TOSVERT VF-FS1 Series - page 8

    E6581373 - 7 - 2.2.2. Status LED It displays node status with green color. LIU007Z does not have this LED. 1 2 3 4 5 6 12 LED OFF LED ON Power ON Time (second) Continues to be OFF Continues to be ON Repeats ON and OFF Repeats ON and OFF Repeats ON and OFF Repeats ON and OFF No LED state Description 1 Although the inverter is tur ned on, LED rem ain ...

  • Toshiba TOSVERT VF-FS1 Series - page 9

    E6581373 - 8 - 2.3. RS485 comm unication port RS485 port is usef ul for RS485 serial com m unication option (USB001Z ) or Rem ote Keypad (RKP002Z). Refer to the inver ter instruc tion m anual for details . N.B.: Caution for LIU007Z W hen a RS485 port of LIU007Z is used f or RS485 ser ial com munic ation option, the com m unication option interrupts ...

  • Toshiba TOSVERT VF-FS1 Series - page 10

    E6581373 - 9 - 3. Configurations 3.1. Neur on ID L ON W ORKS device has the individual Neuron ID. The ID is indicated on the option unit as the barcode (EAN128). Produc ts have 3 stick er labels where the Neuron ID is indicated. 3.2. Service pin Service pin func tion caus es the node to propagate the servic e m essage over the network so that the n ...

  • Toshiba TOSVERT VF-FS1 Series - page 11

    E6581373 - 10 - 3.6. Command & Setpoint selection (Local/Remote) Indication to display Local/Remote m ode is on the inverter unit (Ref er to the inverter instruction m anual for details ). L ON W ORKS option com mand and s etpoint are activated on Rem ote m ode *1 . L ON W ORKS option unit propagates the Local / Remote s tatus to the network as ...

  • Toshiba TOSVERT VF-FS1 Series - page 12

    E6581373 - 11 - 3.7. Reference parameter of the inverter Referenc e param eter of the inver ter is listed below. Title Nam e Descr iption acc Acceleration tim e dec Deceleration tim e fh Maxim um f requency ul Upper lim it frequenc y ll Lower limit f requency vl Base fr equency 1 Do not change these param eters , becaus e the L ON W ORKS option uni ...

  • Toshiba TOSVERT VF-FS1 Series - page 13

    E6581373 - 12 - 4. Functional profile 4.1. Functional profil e supported by thi s option Thi s L ON W ORKS option unit supports L ON M ARK Variable Speed Motor Drive func tional profile (SFPTvar iableSpeedMotorDrive, 6010_11). It has 2 objec ts (func tional block s) shown in the f igure below. Node Object (Mandatory) Variable Speed Motor Drive Obje ...

  • Toshiba TOSVERT VF-FS1 Series - page 14

    E6581373 - 13 - 5. Node Object functional block The Node Object func tional block includes 2 m andatory network var iables “nviReques t (Objec t request)” and “nvoStatus (objec t status)” . Upon receiving an update to the “nviRequest” network variable, the request is pr ocessed and the “nvoStatus” network variable is updated with ei ...

  • Toshiba TOSVERT VF-FS1 Series - page 15

    E6581373 - 14 - 5.2.1. nciLocation (Location Label) Configuration pr operty , Node Object 0000_20 ( Optional) SNVT type: SNVT_str_as c (36) SCPT ref erence: SCPT _location ( 17) It can be used to provide physical location inf orm ation. - Valid Range: Any NULL ( “ 0” ) term inated ASCII str ing of 31 bytes total length. In f act 30 bytes are av ...

  • Toshiba TOSVERT VF-FS1 Series - page 16

    E6581373 - 15 - 5.2.3. nvoStatus (Obj ect Status) Output network var iable, Node Object 0000_20 (Mandator y ) SNVT type: SNVT_obj_status (93) This is the variable to inform the object s tatus. L ON W ORKS option unit supports s ome status s hown in the table below. Bit Request Description --- object_id object_id of requested f unctional block 0 inv ...

  • Toshiba TOSVERT VF-FS1 Series - page 17

    E6581373 - 16 - 6. ACMotorDriv e functional block ACMotorDrive f unctional block includes the “V ariable Speed Motor Drive (6010_11)”. It can perf orm Run/stop contr ol of the inverter , intensive surveillanc e c ontrol of an oper ation state, m onitor the inver ter status through network variables. 6.1. Object map The obj ect m ap is the follo ...

  • Toshiba TOSVERT VF-FS1 Series - page 18

    E6581373 - 17 - 6.2. Netw ork variable list (VSD_6010_11) L ON W ORKS option unit supports all m andatory netw or k variables included in L ON M ARK func tional profile “Variable Speed Motor Drive” . The network variables are s hown in the table below. “nvi” m eans an input network variables , “nvo” m eans an output network variables an ...

  • Toshiba TOSVERT VF-FS1 Series - page 19

    E6581373 - 18 - 6.3. Netw ork variable list (the other) The other network variables ar e shown in the table below. . LIU 007Z LIU 006Z Variables SNVT_ty pe. unit Def ault value v nviResetFault SNVT_switch 0.5%,1 {0.0%, 0} v nviInvSetFreq SNVT _freq_hz 0.1Hz 3276.7Hz = invalid v nvoStatusW ord SNVT _state boolean v nvoDrvFeedback SNVT _switch 0.5%,1 ...

  • Toshiba TOSVERT VF-FS1 Series - page 20

    E6581373 - 19 - 6.4. Confi guration properti es 6.4.1. nciMaxSpeed ( Maximum Speed ) Configuration pr operty (nc50), Var iable Speed Drive 6010_11 (Mandatory) SNVT type: SNVT_lev_percent ( 81) SCPT ref erence: SCPT m axSetpoint (50) It is used to define the m axim um speed of the inverter output. T he value is entered as a per cent of nominal speed ...

  • Toshiba TOSVERT VF-FS1 Series - page 21

    E6581373 - 20 - 6.4.3. nciRcvHrtB t (Receiv e Heartbeat Time) Configuration pr operty , Vari able Speed Drive 6010_11 (Optional) SNVT type: SNVT_tim e_sec ( 107) SCPT ref erence: SCPT m axRcvT im e (48) It is used to contr ol the m axim um per iod of tim e that elapses af ter the last update of the network variables (“ nviDrvSpeedStpt”, ”nviD ...

  • Toshiba TOSVERT VF-FS1 Series - page 22

    E6581373 - 21 - 6.4.6. nciNmlSpeed (Nominal M otor Speed in min -1 ) Configuration pr operty , Variable Speed Drive 6010_11 (Mandatory) SNVT type: SNVT_rpm (102) SCPT ref erence: SCPT nom RPM (158) It is used to provide the nom inal s peed of the inverter output in m in -1 . - Valid range: 0 to 65534 m in -1 - Unit: 1 min -1 - Default value: 1800 m ...

  • Toshiba TOSVERT VF-FS1 Series - page 23

    E6581373 - 22 - 6.4.9. nciRampDow nTm (Ramp Dow n Time) Configuration pr operty , Variable Speed Drive 6010_11 (Mandatory) SNVT type: SNVT_tim e_sec ( 107) SCPT ref erence: SCPT ram pDownTm (161) It determ ines the ram p down time of the motor . - Valid range: 0.1 to 3200.0 sec. - Unit: 0.1 sec. - Default value: 10.0 s ec. N.B.: By editing this var ...

  • Toshiba TOSVERT VF-FS1 Series - page 24

    E6581373 - 23 - 6.5. Input netw ork variable s 6.5.1. nviD rvSpeedSt pt (Drive Speed Setpoint) Input network variable, Var iable Speed Drive 6010_11 (Mandatory) SNVT type: SNVT_switch (95) It provides star t/stop control and a low res olution speed setpoint as a per cent of nom inal speed. Output fr equency = “nciNmlFr eq” x “nviDr vSpeedStpt ...

  • Toshiba TOSVERT VF-FS1 Series - page 25

    E6581373 - 24 - 6.5.4. nviInv SetFreq (Frequency Setpoint) Input network variable SNVT type: SNVT_fr eq_hz (76) It provides speed setpoint in Hz. T he rotation di rection is provided by “ nviDrvSpeedScale” (Negative value means in revers e). - Valid range: 0.0 Hz to the max imum vale in the inverter . (Refer to the inverter instr uction m anual ...

  • Toshiba TOSVERT VF-FS1 Series - page 26

    E6581373 - 25 - - Valid range LIU007Z LIU006Z Bit Term inal Par ameter T erm inal Param eter 0 --- --- 1 --- --- 2 --- --- 3 --- --- 4 --- --- 5 --- --- 6-15 --- --- If multiple digital output c ontrol s ignals are used at the sam e tim e, the output value is the OR of all digital output controls. 6.5.7. nviA nalogOut1,2 (Control of A nalog output) ...

  • Toshiba TOSVERT VF-FS1 Series - page 27

    E6581373 - 26 - 6.5.9. nviParamCmd (Parameter access) Input network variable SNVT type: SNVT_preset ( 94) It is used to acces s the inverter par ameter s. Refer to s ection 7.5 “Param eter ac cess m ethod” f or the exam ple usage. - Valid range: All acc essible param eter s in the inverter - Format: field Length Descr iption learn 1 by te Comm ...

  • Toshiba TOSVERT VF-FS1 Series - page 28

    E6581373 - 27 - 6.6. Output netw ork variables 6.6.1. Output netw ork variable update Norm ally , output network variables are updated when the inverter st atus was changed. Autom atic transm ission func tion is also prepared by “nciSndHrtBt (Send Heartbeat Tim e)”, “ nciMinOutT m (Minim um Send Tim e)” c onfiguration pr operties. See secti ...

  • Toshiba TOSVERT VF-FS1 Series - page 29

    E6581373 - 28 - 6.6.6. nvoDrvFeedback ( Velocity Feedback) Output network var iable SNVT type: SNVT_switch (95) It provides stopped / r unning status and low resolution output s peed of the m otor. - Specif ication nvoDrvFeedback value state Operation N/A 0 Stop 0.0 to 127.5% 1 Drive at 0.0 to 127.5% speed. value = (Drive f requency) / nciNm lFreq ...

  • Toshiba TOSVERT VF-FS1 Series - page 30

    E6581373 - 29 - 6.6.9. nvoA larmWord (Alarm Status) Output network var iable SNVT type: SNVT_state (83) It provides the inverter fault status . If the inverter faulted, “Fault” bit and the contents bit are set to ON. Bit De scription 0 Fault 1 Supply fault 2 Inverter fault 3 Motor f ault (overvoltage, phase los s, overheating ...) 4 Process fau ...

  • Toshiba TOSVERT VF-FS1 Series - page 31

    E6581373 - 30 - 6.6.13. nv oDrvEnergy (Cumulative Input Energy ) Output network var iable, SNVT type: SNVT_elec_k wh_l (146) It provides the cum ulative input ener gy c alculated by the inverter. - Valid range: 0.0k W h to 42949672.9kW h ( If an overf low occurred, the value retur ns to 0.) - Unit: 0.1k W h *How to clear the value This cum ulative ...

  • Toshiba TOSVERT VF-FS1 Series - page 32

    E6581373 - 31 - The relations hip between the network variables and input ter minals is shown in below. Variables LIU007Z LIU006Z nvoDigitalIn1 F term inal nvoDigitalIn2 R term inal nvoDi gitalIn3 ------- nvoDi gitalIn4 ------- nvoDi gitalIn5 ------- nvoDi gitalIn6 ------- nvoDi gitalIn7 ------- nvoDi gitalIn8 ------- 6.6.16. nvoA nalogIn1 to 3 (A ...

  • Toshiba TOSVERT VF-FS1 Series - page 33

    E6581373 - 32 - 6.6.18. nvoParamResp (P arameter Access Response) Output network var iable SNVT type: SNVT_preset ( 94) It provides to the respons e of the inverter par ameter s acce ssing ( nviParam Cm d). Refer to section 7.5 “Param eter acc ess m ethod” for the exam ple usage. - Format field Length Description learn 1 byte Command 2 (LN_LEAR ...

  • Toshiba TOSVERT VF-FS1 Series - page 34

    E6581373 - 33 - 7. Example usage 7.1. Procedure Lower exam ple shows the procedur e to send the 100% speed drive c omm and to the inverter . 1. Comm iss ion Make a network tool to identify this option by using s ervice pin f unction (ref er to network tool manual in detail) . 2. Binding Refer to nex t section. 3. Configurations Set correc t value i ...

  • Toshiba TOSVERT VF-FS1 Series - page 35

    E6581373 - 34 - 7.4. Communicati on health management This option unit has com m unication health m anagem ent function. 1. Comm unic ation time out f unction (nciRc vHrtBt) This value manages the com m unication time out func tion. T his option unit would initialize the drive com m and/setpoint variables and try to stop the m otor in c ase of not ...

  • Toshiba TOSVERT VF-FS1 Series - page 36

    E6581373 - 35 - 7.5. Parameter access method Param eter acc ess is allowed by us ing nviParam Cm d and nvoParam Resp network var iables. T he struc ture form at is shown in below table. Field Length Descr iption learn 1 byte Command 2 (LN_LEARN_VAL UE) : W rite 3 (LN_REPORT_VALUE) : Read selector 2 by tes Param eter address (unsigned value) value[0 ...

  • Toshiba TOSVERT VF-FS1 Series - page 37

    E6581373 - 36 - - Exam ple 3: Illegal acc ess Illegal data is written to the inverter param eter f171 , (Base f requency voltage, address 0171) . The upper lim it value is 330.0V ( 200V class) . In case of writing 360.0V, the unit of this param eter is 0.1V and the data value is converted to hexadecim al, s o the value is 0E10 hex . The controller ...

  • Toshiba TOSVERT VF-FS1 Series - page 38

    E6581373 - 37E - 8. Specifications Item Specific ation Notes Number of dom ains 2 Number of addres s entries 37 Number of alias tables 8 Comm unic ation transceiver Free topology transceiver TP/FT -10 channel type. ANSI/EIA/CEA 709.3 Baudrate 78k bps Protocol LonT alk ANSI/EIA 709.1 Comm unic ation signal 2 wi res plus s hield NETA, Sheild, NET B T ...

Manufacturer Toshiba Category Power Supply

Documents that we receive from a manufacturer of a Toshiba TOSVERT VF-FS1 Series can be divided into several groups. They are, among others:
- Toshiba technical drawings
- TOSVERT VF-FS1 Series manuals
- Toshiba product data sheets
- information booklets
- or energy labels Toshiba TOSVERT VF-FS1 Series
All of them are important, but the most important information from the point of view of use of the device are in the user manual Toshiba TOSVERT VF-FS1 Series.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Toshiba TOSVERT VF-FS1 Series, service manual, brief instructions and user manuals Toshiba TOSVERT VF-FS1 Series. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Toshiba TOSVERT VF-FS1 Series.

Similar manuals

A complete manual for the device Toshiba TOSVERT VF-FS1 Series, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Toshiba TOSVERT VF-FS1 Series by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Toshiba TOSVERT VF-FS1 Series.

A complete Toshiba manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Toshiba TOSVERT VF-FS1 Series - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Toshiba TOSVERT VF-FS1 Series, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Toshiba TOSVERT VF-FS1 Series, that we can find in the current document
3. Tips how to use the basic functions of the device Toshiba TOSVERT VF-FS1 Series - which should help us in our first steps of using Toshiba TOSVERT VF-FS1 Series
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Toshiba TOSVERT VF-FS1 Series
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Toshiba TOSVERT VF-FS1 Series in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Toshiba TOSVERT VF-FS1 Series?

Use the form below

If you did not solve your problem by using a manual Toshiba TOSVERT VF-FS1 Series, ask a question using the form below. If a user had a similar problem with Toshiba TOSVERT VF-FS1 Series it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)