Manual Xantrex Technology HW 1000

52 pages 1.32 mb
Download

Go to site of 52

Summary
  • Xantrex Technology HW 1000 - page 1

    Fr eedom HW 1000 Inverter/Char ger Installation Guide ...

  • Xantrex Technology HW 1000 - page 2

    ...

  • Xantrex Technology HW 1000 - page 3

    This guide for use by qualified installers only Freedom HW 1000 Inverter/Charger Installation Guide ...

  • Xantrex Technology HW 1000 - page 4

    This guide for use by qualified installers only About Xantrex Xantrex T echnology Inc. (www .xantr ex.com), a subsidiary of Schneider Electric, is a world leade r in the development, manufacturing and marketing of ad vanced power electronic products and systems for the renewable and mobile power markets. The comp any's products convert a nd co ...

  • Xantrex Technology HW 1000 - page 5

    iii This guide for use by qualified installers only About This Guide Purpose The purpose of this Instal lation Guide is to provide explanations and procedures for setting up and insta lling a Freedom HW Install ation*. For complete information on how to op erate, maintain, and troubleshoot the Freedom HW unit, see the Freedom HF Inverter/Charger Ow ...

  • Xantrex Technology HW 1000 - page 6

    About T his Guide iv 975-0468-01-01 This guide for use by qualified installers only Conventions Used The following co nventions are used in thi s guide. Related Information Y ou can find more information about Xant rex T echnology Inc. as well as its products and services at www .xantrex.com WA R N I N G W arnings identify conditions or practices t ...

  • Xantrex Technology HW 1000 - page 7

    v This guide for use by qualified installers only Important Safety Instructions R EAD AND SAVE THIS I NSTALLATION G UIDE FOR FUTURE REFERENCE . This chapter contains im portant safety and operating instructions for the Freedom HW Inverter/Charg er unit. 1. Before installing and using the Freed om HW, read all instructions and cautionary markings on ...

  • Xantrex Technology HW 1000 - page 8

    vi 975-0468-01-01 This guide for use by qualified installers only 6. Do not disassemble the Freedom HW. It contains no user-serviceable parts. See W arranty for instructions on obtaining service. Attempting to service the Freedom HW yourself ma y result in a risk of elec trical shock or fire and will void your wa rranty . Internal capacitors remain ...

  • Xantrex Technology HW 1000 - page 9

    975-0468-01-01 vii This guide for use by qualified installers only P ersonal Pr ecautions W hen W orking With Batteries 1. Study and follow all of the battery manufacturer's specific precautions, such as removing or not removing cell caps while charging, and recommended rates of char ge. 2. Add distilled water in each cell until battery aci d ...

  • Xantrex Technology HW 1000 - page 10

    viii 975-0468-01-01 This guide for use by qualified installers only 12. Never charge a frozen battery . 13. Clean battery terminals. Be careful to keep corrosion from coming into contact with your eyes. 14. Locate the Freedom HW unit awa y from batteries in a separate, well ventilated compartment. 15. Never place the Freedom HW un it directly above ...

  • Xantrex Technology HW 1000 - page 11

    975-0468-01-01 ix This guide for use by qualified installers only Important Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - v 1 Installation Materials List - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–2 Safety Instructions - - - - - - - - - - - - - - ...

  • Xantrex Technology HW 1000 - page 12

    x This guide for use by qualified installers only 2 Specifications Electrical Specifications: Inverter Mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–2 Electrical Specifications: Charge Mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–3 Environmental Specifications - - - - - - - - - - - - - - - - - - - ...

  • Xantrex Technology HW 1000 - page 13

    1–1 This guide for use by qualified installers only 1 Installation Chapter 1 provides information to help in installing a Freedom HW Inverter/C harger Installation. It covers the following: • Materials list. • Safety instructions and various installation codes that may be applicable to your installation. • Sample installation tools and mate ...

  • Xantrex Technology HW 1000 - page 14

    1–2 975-0468-01-01 This guide for use by qualified installers only Materials List Y our Freedom HW Inverter/Charger package includes the items listed below . • Freedom HW Inverter/Charg er unit • display panel (p/n: 808-9 557) with 7-inch (0.17 m) display panel ca ble (p/n: 053-0049-02) • display panel moun ting plate (p/n: 80 8-9555) • d ...

  • Xantrex Technology HW 1000 - page 15

    Safety Instructions 975-0468-01-01 1–3 This guide for use by qualified installers only Safety Instructions • Before you begin the i nstallation, review the “Important Safety Instructions” on page v, and read th is entire “Installation” section so you can plan your installation from beginning to end. • Disconnect all AC and DC power so ...

  • Xantrex Technology HW 1000 - page 16

    1–4 975-0468-01-01 This guide for use by qualified installers only Installation T ools and Materials Y ou will need the following to install the Freedom HW: ❐ W ire stripper ❐ Mounting screws or bolts ❐ #2 Phillips screwdriver ❐ W rench for DC terminals (1/2 inch or 13mm or adjustable) ❐ AC cable (i.e. 2-conductor-plus-ground cable), si ...

  • Xantrex Technology HW 1000 - page 17

    Basic Installation Procedures 975-0468-01-01 1–5 This guide for use by qualified installers only Basic Installation Procedures Xantrex recommends that you h ave your installation performed by a qualified technician or electrician. This section provides sample installa tion information as a guide for your installation. For your convenience, th e o ...

  • Xantrex Technology HW 1000 - page 18

    1–6 975-0468-01-01 This guide for use by qualified installers only Step 1: Designing the Installation Most Freedom HW installations share common components, and some of these are briefly described below . Figure 1-2 shows some components and their relationshi p to each oth er in a typical recreational vehicle or fleet vehicle installation. Figure ...

  • Xantrex Technology HW 1000 - page 19

    Basic Installation Procedures 975-0468-01-01 1–7 This guide for use by qualified installers only AC shore power A source of 120 V , 60Hz sine wave alternating current is needed to provide energy to char ge batteries and pass power through to AC loads. This source is usually the utility grid (power company) or an AC generator . An automatic or man ...

  • Xantrex Technology HW 1000 - page 20

    1–8 975-0468-01-01 This guide for use by qualified installers only AC Output: The circuit breaker or fuse must be rated at no more than the rating of the input breaker in the installation and must be approved for use on 120 V ac branch circuits. The wire used between the Freedom HW and the AC output breaker must be of adequate size to match the A ...

  • Xantrex Technology HW 1000 - page 21

    Basic Installation Procedures 975-0468-01-01 1–9 This guide for use by qualified installers only AC breakers and fuses must be sized to adequately protect the w iring that is installed on the input and output AC circuits of the Freedom HW. All breakers and wiring must be sized an d connected in accordance with the electrical codes or regulations ...

  • Xantrex Technology HW 1000 - page 22

    1–10 975-0468-01-01 This guide for use by qualified installers only DC Disconnects and Over- Current Devices The DC circuit from the battery to the Freedom HW must be equipped with a disconnect and over -current de vice. This usually consists of a circuit breaker , a “fused-disconnect,” or a separate fuse and DC disconnect. Do not confuse AC ...

  • Xantrex Technology HW 1000 - page 23

    Basic Installation Procedures 975-0468-01-01 1–11 This guide for use by qualified installers only Ground Fault Circuit Interrupters (GFCIs) A GFCI is a device that de-energizes a circuit when a current to ground exceeds a specified value that is less th an that required to blow the circuit breaker . GFCIs are intended to protect peop le from elec ...

  • Xantrex Technology HW 1000 - page 24

    1–12 975-0468-01-01 This guide for use by qualified installers only Step 2: Choosing a Location for the Freedom HW The Freedom HW should only be inst alled in locations that meet the following requirements: ❐ Dry . Do not allow water or other flui ds to drip or splash on the Freedom HW. Do not mount the Freedom HW in an ar ea subject to splashi ...

  • Xantrex Technology HW 1000 - page 25

    Basic Installation Procedures 975-0468-01-01 1–13 This guide for use by qualified installers only Step 3: Mounting the Freedom HW T o mount the Freedom HW: 1. Remove the Freedom HW fro m its shipping container , verify that all components are present, and record relevant product information on Freedom HF Inverter/Charger Ow ner ’ s Guide (Doc. ...

  • Xantrex Technology HW 1000 - page 26

    1–14 975-0468-01-01 This guide for use by qualified installers only Connecting the Equipment Ground The Freedom HW has a ground stud on the side of the u nit as shown in Figure 1-4. Follow the guidelines in “Grounding Locatio ns” to co nnect the inverter ’ s chassis to the ground. Grounding Locations Y ou must connect the equipm ent ground ...

  • Xantrex Technology HW 1000 - page 27

    Basic Installation Procedures 975-0468-01-01 1–15 This guide for use by qualified installers only Step 4: Connecting the A C Input W ires General A C W iring Considerations AC cable size The AC input cable may be either solid or stranded (as required), but must have three conductors and be sized as in T able 1-4 on page 1–16 . AC W iring Connec ...

  • Xantrex Technology HW 1000 - page 28

    1–16 975-0468-01-01 This guide for use by qualified installers only There are two knockouts on th e front panel for AC input and output wiring. When making the AC input and AC output connections, observe the correct color code for the appropriate AC wire, as described in T able 1-5. A C Input Connections 1. Ensure that AC and DC power are both OF ...

  • Xantrex Technology HW 1000 - page 29

    Basic Installation Procedures 975-0468-01-01 1–17 This guide for use by qualified installers only 6. Strip about 2 inches (50 mm) from th e jacket of the AC input cable. The AC input cable may be either so lid or stranded (as required), but must have three conductors and be sized as in T able 1-4 on page 1– 16 . (The AC terminal block accepts w ...

  • Xantrex Technology HW 1000 - page 30

    1–18 975-0468-01-01 This guide for use by qualified installers only Step 5: Connecting A C Output to an Existing A C Circuit Do not connect the Fr eedom HW to an AC branch circuit that has high-power consumption loads. The Freedom HW will not operate el ectric heaters, air conditioners, stoves, and other electrica l appliances that consume more t ...

  • Xantrex Technology HW 1000 - page 31

    Basic Installation Procedures 975-0468-01-01 1–19 This guide for use by qualified installers only T o make a permanent connection to existing AC wiring (continuing from # 13 of “S tep 4: Connecting the AC Input Wires” on page 1–15): 1. Ensure that AC and DC power are both OFF . 2. Install the required value of circui t breaker in the AC loa ...

  • Xantrex Technology HW 1000 - page 32

    1–20 975-0468-01-01 This guide for use by qualified installers only 1 1. Insert the Line and Neutral wires into the corresponding terminals. 12. T ighten the wire attachment screws to a torqu e of 1 5.6 –2 1.6 in-lbf (1.76–2.44 N-m). Leave som e wi ring slack inside the wiring compartment. Ensure you have maintai ned correct polarity and that ...

  • Xantrex Technology HW 1000 - page 33

    Basic Installation Procedures 975-0468-01-01 1–21 This guide for use by qualified installers only In this wiring diagram, the AC in put to the Freedom HW comes from the main AC panel which contains the in put circuit breaker . The AC output wiring is routed to a separate invert er subpanel with a dedicated circuit breaker . Figure 1-6 AC W iring ...

  • Xantrex Technology HW 1000 - page 34

    1–22 975-0468-01-01 This guide for use by qualified installers only In this wiring diagram, the AC inpu t to the Freedom HW comes directly from an AC source. Th e AC source input wiri ng must be protected by an AC breaker of 30 A max. Th e output wiring is routed t o the main AC panel which is also pro tected by AC breakers or circuit breakers. F ...

  • Xantrex Technology HW 1000 - page 35

    Basic Installation Procedures 975-0468-01-01 1–23 This guide for use by qualified installers only Step 6: Connecting the DC Cables Follow the procedure given below to connect the battery leads to the terminals on the DC end. The cables should be as short as possible and large en ough to handle the required current, in accordance with the electric ...

  • Xantrex Technology HW 1000 - page 36

    1–24 975-0468-01-01 This guide for use by qualified installers only T o make the DC connections Refer to Figure 1-9. 1. Make sure the inverter is off and no AC or DC is connected to the unit. 2. Remove the nuts and washers from the Freedom HW positive and negative DC termina ls . 3. S trip 1/2 inch (13 mm) to 3/4 in ch (19 mm) insulation from one ...

  • Xantrex Technology HW 1000 - page 37

    Basic Installation Procedures 975-0468-01-01 1–25 This guide for use by qualified installers only 10. Install the lock washer and nut that are supplied with the inverter . T ighten the nut to a torque of 108–1 20 in-lbf (12.2–13.6 N-m). Make the connectio n snug enough so th e ring terminal do es not move around on the DC terminal, but do not ...

  • Xantrex Technology HW 1000 - page 38

    1–26 975-0468-01-01 This guide for use by qualified installers only 13. Install the lock washer and nut that are supplied. T ighten the nut to a torque of 108–120 in-lbf (12. 2–13.6 N-m). Make the connection snug enough so the ring terminal do es not move around on the DC terminal, but do not overtighten. DC Grounding T o connect the DC groun ...

  • Xantrex Technology HW 1000 - page 39

    Basic Installation Procedures 975-0468-01-01 1–27 This guide for use by qualified installers only Step 7: Mounting the Display P anel Xantrex has three communications ca bles of dif ferent lengths available for purchase. Choose a 25-foot cable (p/n: 31 -6257-00), 50-foot cabl e (p/n: 31-6262-00), or a 70-fo ot cable (p/n: 31-6275-00). Flush mount ...

  • Xantrex Technology HW 1000 - page 40

    1–28 975-0468-01-01 This guide for use by qualified installers only Step 8: T esting Y our Installation There are two tests to be performed. The first test verifies that the Freedom HW is inverting DC battery power and delivering AC power to its output. The second test is intended for inst allations where AC input and output is hard wired to the ...

  • Xantrex Technology HW 1000 - page 41

    Basic Installation Procedures 975-0468-01-01 1–29 This guide for use by qualified installers only T esting in Shore P ower Mode T o test the Freedom HW in shor e power mode: ◆ W ith the appliance from the prev ious test still connected and operating, connect the shore power source. The Freedom HW transfers the applia nces to shore power . The s ...

  • Xantrex Technology HW 1000 - page 42

    1–30 ...

  • Xantrex Technology HW 1000 - page 43

    2–1 2 Specifications Chapter 2 contains electrical performance information and product specifications. Note: Specifications are subject to change without notice. ...

  • Xantrex Technology HW 1000 - page 44

    2–2 975-0468-01-01 Electrical Specifications: Inverter Mode DC Input Low operating vo l tage range “ SdL ” setting 10.5–15.5 V High operating voltage range “ SdH ” setting 1 1.8–15.5 V Under voltage alarm/shut down Under voltage recovery “ SdL ” setting 10.5/1 1.0 V 12.0 V Under voltage alarm/shut down Under voltage recovery “ S ...

  • Xantrex Technology HW 1000 - page 45

    Electrical Specifications: Charge Mode 975-0468-01-01 2–3 Electrical Specifications: Charge Mode A C Input Operating voltag e range 95–135 V ac Nominal current 12Aac at 55A char ge, 120 V ac in Nominal frequency 60 Hz DC Outp ut Nominal voltage 12.0 Vdc Min battery voltage for charging 0.0 Vdc Max output voltage 14.4 Vdc Nominal output current ...

  • Xantrex Technology HW 1000 - page 46

    2–4 975-0468-01-01 Environmental Specifications System Specifications Physical Specifications Operating T emperature Ran ge 32–104 ºF (0–40 ºC), with output derated above 77 ºF (25 °C) Storage T em perat ure Range -40–1 58 ºF (-40– 70 ºC) Humidity: Operation/ Storage 5–95% RH, non-condensing Pass-through 120 V ac, 60 Hz, 30 A, 3-h ...

  • Xantrex Technology HW 1000 - page 47

    Regulatory Approvals 975-0468-01-01 2–5 Regulatory Approvals Inverter Overload Operation This graph shows how long (measured in seconds) the Freedom HW will operate for a given ou tput current (measured in Amps). The graph illustrates invert er operation at 25 °C. ETL approved to CSA 107.1, UL458 10 12 14 16 18 20 30 40 50 Time (sec) 1600 1400 1 ...

  • Xantrex Technology HW 1000 - page 48

    2–6 975-0468-01-01 Invert P ower Derating vs . Ambient T emperature If the unit is in inverter mode and in elevated am bient temper ature above 25 °C, you will have to reduce power draw acco rding to the following chart to avoid over-t emperature shutdown. 0 Watts 50 °C 25 30 35 40 45 1000 900 750 ~33 °C 30 °C 900 W 850 W 800 W 750 W @ 12.5 V ...

  • Xantrex Technology HW 1000 - page 49

    Charger Output Current vs . AC Input V oltage 975-0468-01-01 2–7 Charger Output Curr ent vs . A C Input V oltage When the Freedom HW is charging batteries from a weak shore power source the AC voltage may fall as the Freedom HW draws current. T o reduce the chance of the shore po wer voltage collapsing below the configured transfer level the Free ...

  • Xantrex Technology HW 1000 - page 50

    2–8 ...

  • Xantrex Technology HW 1000 - page 51

    ...

  • Xantrex Technology HW 1000 - page 52

    Xantrex Technology Inc. 1 800 670 0707 Tel toll free NA 1 408 987 6030 Tel direct 1 800 994 7828 Fax toll free NA customerservice@xantrex.c om www.xantrex.com 975-0468-01-01 Printed in China ...

Manufacturer Xantrex Technology Category Battery Charger

Documents that we receive from a manufacturer of a Xantrex Technology HW 1000 can be divided into several groups. They are, among others:
- Xantrex Technology technical drawings
- HW 1000 manuals
- Xantrex Technology product data sheets
- information booklets
- or energy labels Xantrex Technology HW 1000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Xantrex Technology HW 1000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Xantrex Technology HW 1000, service manual, brief instructions and user manuals Xantrex Technology HW 1000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Xantrex Technology HW 1000.

A complete manual for the device Xantrex Technology HW 1000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Xantrex Technology HW 1000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Xantrex Technology HW 1000.

A complete Xantrex Technology manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Xantrex Technology HW 1000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Xantrex Technology HW 1000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Xantrex Technology HW 1000, that we can find in the current document
3. Tips how to use the basic functions of the device Xantrex Technology HW 1000 - which should help us in our first steps of using Xantrex Technology HW 1000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Xantrex Technology HW 1000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Xantrex Technology HW 1000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Xantrex Technology HW 1000?

Use the form below

If you did not solve your problem by using a manual Xantrex Technology HW 1000, ask a question using the form below. If a user had a similar problem with Xantrex Technology HW 1000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)