Manual Chauvet Geyser RGB

15 pages Not applicable
Download

Go to site of 15

Summary
  • Chauvet Geyser RGB - page 1

    User Manual ...

  • Chauvet Geyser RGB - page 2

    Page 2 of 16 Geyser ™ RGB User Manual Rev. 6 T ABLE OF C ON TENTS 1. Before You Begin .......................................................................................................... 3 W hat Is Included ............................................................................................................................... 3 Unpac ...

  • Chauvet Geyser RGB - page 3

    Geyser ™ RGB User Manual Rev. 6 Page 3 of 16 1. B EFORE Y OU B EGIN What I s Incl uded · Geyser ™ RGB · Geyser™ RGB Wireless R emote Control · Geyser™ R GB Wired Remot e Receiver · Power Cord · Warranty C ard · Quick Refere nce Guide Unpacki ng Instr uctions Carefully unpack the produc t immediately and check the contain er to make su ...

  • Chauvet Geyser RGB - page 4

    Page 4 of 16 Geyser ™ RGB User Manual Rev. 6 Product at a Glance Use on Dim mer x Auto Progr ams P Outdoor Us e x Fixed v oltage ( 120 V or 230 V ) P Sound - Act ive x Replaceab le Fuse P DMX P User - Serviceable x Master/ Slave x Safety No tes T he se n ot es include im porta nt i nformat ion about the mountin g, usage, a nd mainten ance of this ...

  • Chauvet Geyser RGB - page 5

    Geyser ™ RGB User Manual Rev. 6 Page 5 of 16 2. I NTRO DUCTIO N Over vi ew LED Dis play 3- pin DMX In/Out Nozzle and LEDs Fluid Tan k On/Off Swi tch Safety Eye Loop Remote C ontrol Receiv er Port Fuse Hol der Power I n Handles 5- pin DMX In/Out Alternate Safety Eye Loop Attachment Point Safety Cable Attachment Point (Underside) ...

  • Chauvet Geyser RGB - page 6

    Page 6 of 16 Geyser ™ RGB User Manual Rev. 6 Dimens ions ...

  • Chauvet Geyser RGB - page 7

    Geyser ™ RGB User Manual Rev. 6 Page 7 of 16 3. S ETUP AC P o w er The Geyser ™ RGB has a fixed voltag e power supply and it can work w ith an input voltage of e ither 120 V , 60 Hz or 230 V , 50 Hz , depending on the specifi c model. To determine the product’ s power requir ements ( circuit breaker, pow er outlet, and wiring) , use the curr ...

  • Chauvet Geyser RGB - page 8

    Page 8 of 16 Geyser ™ RGB User Manual Rev. 6 Mounti ng Before mount ing the p roduc t , read an d follow the safe ty recomm endations indi cated in the Safety Notes . Orientation Primarily, t he Geyser ™ RGB is to b e floo r mounted in a v ert ic al fog jet or ient atio n . T he Geyser ™ RG B may also be mounted in a floor mounting/ horizonta ...

  • Chauvet Geyser RGB - page 9

    Geyser ™ RGB User Manual Rev. 6 Page 9 of 16 A lt ernate Inverted Truss Mounting With inverted moun ting, av oid spillage of the fog f luid by setting the fluid tank i n an upright position. Be sur e to use a safety cable for bo th the Gey ser™ RGB and the fluid tank when rigging i n this manner. M12 - sized bolts fit the th readed m ountin g h ...

  • Chauvet Geyser RGB - page 10

    Page 10 of 16 Geyser ™ RGB User Manual Rev. 6 Tank Inver sion for Inver ted Mounting 1. Remove the screw s and the b ottle lock t o take out the t ank. 2. Turn the fog machine upside d own and remov e the screw s to take off the removable p late. 3. Attach the removable plat e to the opposite side and secur e the tank w ith the bottle lock . Bott ...

  • Chauvet Geyser RGB - page 11

    Geyser ™ RGB User Manual Rev. 6 Page 11 of 16 4. O PERATI ON Control Panel Opera tion To access t he control pane l function s, use the f our buttons located undernea th the display. Button Function <MENU > Selects an op eration mod e or to back s out of the curr ent menu opt ion p ( <UP> ) Scrolls up the list of options or select s a ...

  • Chauvet Geyser RGB - page 12

    Page 12 of 16 Geyser ™ RGB User Manual Rev. 6 DMX Channe l Modes, A ssi gnments , and Value s 8-C hannel Channel Function Value Setting 1 Fog 000 ó 009 No f unct ion 010 ó 255 Fog on 2 Red 000 ó 00 9 No f unct ion 01 0 ó 255 0– 100% 3 Green 000 ó 009 No f unct ion 010 ó 255 0– 100% 4 Blue 000 ó 009 No f unct ion 010 ó 255 0– 100% 5 ...

  • Chauvet Geyser RGB - page 13

    Geyser ™ RGB User Manual Rev. 6 Page 13 of 16 Configur ation (Standa lone) Set the product t o Automatic mode to control without a DMX controll er. 1. Connect the product to a suit able power outlet. 2. Turn the product on. Never con nect a product that is operating in any standal one mode t o a D MX s trin g connected to a DMX c ontroller. P r o ...

  • Chauvet Geyser RGB - page 14

    Page 14 of 16 Geyser ™ RGB User Manual Rev. 6 5. T ECHNI CAL I NFORMATION Fogger Mainte nance Do not allow the fogger to become clogg ed . After ev ery 40 hours of cont inuous operation, use CHAUVET ® Fog Clea ner Quart (FCQ) throug h the system to prevent the accumulati on of partic ulate matt er in the heat ing element. The reco mmended cleani ...

  • Chauvet Geyser RGB - page 15

    Geyser ™ RGB User Manual Rev. 6 Page 15 of 16 6. T ECHNI CAL S PE CIFICATIO NS Dimension s and Weight Length Widt h Height Weight 20 in ( 510 mm) 14.7 in ( 375 mm) 9. 8 in ( 250 mm) 2 1 lb ( 9. 6 kg) Note: Dimensions in inches rounded to the nearest decimal digit. Pow er Power Supply Type Range Voltage Selection Model - specific 120 VAC, 60 Hz or ...

Manufacturer Chauvet Category Effect machine

Documents that we receive from a manufacturer of a Chauvet Geyser RGB can be divided into several groups. They are, among others:
- Chauvet technical drawings
- Geyser RGB manuals
- Chauvet product data sheets
- information booklets
- or energy labels Chauvet Geyser RGB
All of them are important, but the most important information from the point of view of use of the device are in the user manual Chauvet Geyser RGB.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Chauvet Geyser RGB, service manual, brief instructions and user manuals Chauvet Geyser RGB. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Chauvet Geyser RGB.

Similar manuals

A complete manual for the device Chauvet Geyser RGB, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Chauvet Geyser RGB by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Chauvet Geyser RGB.

A complete Chauvet manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Chauvet Geyser RGB - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Chauvet Geyser RGB, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Chauvet Geyser RGB, that we can find in the current document
3. Tips how to use the basic functions of the device Chauvet Geyser RGB - which should help us in our first steps of using Chauvet Geyser RGB
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Chauvet Geyser RGB
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Chauvet Geyser RGB in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Chauvet Geyser RGB?

Use the form below

If you did not solve your problem by using a manual Chauvet Geyser RGB, ask a question using the form below. If a user had a similar problem with Chauvet Geyser RGB it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (1)

alejandro rodriguez

hola tengo un problema para configurar mi maquina para usarla con el control remoto aun siguiendo los pasos en el manual hay alguna forma de hacerle un reset? porque en cuanto calienta solo comienza a arrojar humo y no para