Enterasys C2RPS-SYS - page 1
SecureS t ack C2 Redundant Power System C2RPS-SYS Inst allation Guide C2RPS-CHAS8 C2RPS-PSM Powe r 9033977-0 1 Caution: Do not use this product with SecureS t ack C2 PoE devices. Any SecureS tack C2 device with a “P” suffix in the model number (C2xxxx-xxP) indi cates a SecureS tack C2 PoE-compliant device and is not compatible with this power s ...
-
Enterasys C2RPS-SYS - page 2
...
-
Enterasys C2RPS-SYS - page 3
i Notice Enterasys Networks reserv es the right to make changes in specifica tions and other information containe d in this document and its web site without prior notice. The reader should in all cases consult Enterasys Netw orks ...
-
Enterasys C2RPS-SYS - page 4
ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This device co mplies with Pa r t 15 of the FCC rules. Operation is su bject to the following two conditions: (1) this device may not cause harmfu l interference, ...
-
Enterasys C2RPS-SYS - page 5
iii Electromagnetic Compatibility (EMC) This product complies with the following: 47 CF R Pa r t s 2 and 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000 ‐ 3 ‐ 2, EN 61000 ‐ 3 ‐ 3, EN 55024, AS/NZS CISPR 22, VCCI V ‐ 3. Compatibilidad ...
-
Enterasys C2RPS-SYS - page 6
iv Declaration of Conformity Application of Co uncil Directiv e(s): 89/336/EEC 73/23/EEC Manufacturer’s Na me: Enterasys Networks, Inc. Manufacturer ’ s Address: 50 Minuteman Road Andover, MA 01810 USA European Representativ e Address: Enterasys Networks, Ltd. Nexus House, Newbury Busi ...
-
Enterasys C2RPS-SYS - page 7
v Enterasys Networks, Inc. Firmware License Agreement BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT , CAREFULL Y READ THIS LICENSE AGREEMENT . This document is an agreement (“ Agreement”) betwee n the end user (“Y ou”) and Enterasys Networks, Inc. ...
-
Enterasys C2RPS-SYS - page 8
vi 3. APPLICABLE LAW. This Agreem ent shal l be interpreted and governed under the laws and in the state and federal cour ts of the Commonwealth of Massachusetts wi thout regard to its conflicts of laws provisions. You acc ...
-
Enterasys C2RPS-SYS - page 9
vii 8. AUDIT RIGHTS. You here by acknowl edge that the intellectual property rights associated with the Program are of critical value to Enterasys and, accordingly, You hereby agree to maintain complete books, records and accounts ...
-
Enterasys C2RPS-SYS - page 10
viii ...
-
Enterasys C2RPS-SYS - page 11
ix Contents About this Guide Using This Guide ......... ................ ............. ................ ............. ................ ............. ............. . ................... xi Structure of This Guide ............. ................ ................ ............. ................ ............. ................ ....... .......... xi Using ...
-
Enterasys C2RPS-SYS - page 12
x Figures 1-1 SecureStack C2RPS-CHAS8 (front view without PSMs) ........... ............. ................ ............. .. 1-2 1-2 SecureStack C2RPS-CHAS8 (rear view with eigh t PSMs) ........... ............. ............. ............. .. 1-2 1-3 C2RPS-PSM (front view) .............. ............. ...... ....... ............. ............. ..... ...
-
Enterasys C2RPS-SYS - page 13
SecureStack C2 Installation Guide xi About this Guide This guide prov ides an overview , installation and troubleshooting instructions, and specifications for the Enterasys SecureStack C2RPS ‐ SYS redundant power system components: chassis (C2RPS ‐ CHAS8), p ...
-
Enterasys C2RPS-SYS - page 14
Using the SecureStack C2 Manual Set xii About this Guide Using the SecureS t ack C2 Manual Set Other manuals have been develope d for the SecureStack C2 non ‐ PoE switch devices that can be connected to the RPS for power redundancy . The SecureStack C2 ...
-
Enterasys C2RPS-SYS - page 15
Conventions Used in This Guide SecureStack C2 Installation Guide xiii Conventions Used in This Guide The following conventions are used in this guide: Note: Calls the reader ’s attention to any item of information that may be of spe cial import ance. Caution: Contains information essential to avoid damage to the equipm ...
-
Enterasys C2RPS-SYS - page 16
Conventions Used in This Guid e xiv About this Guide ...
-
Enterasys C2RPS-SYS - page 17
SecureStack C 2 Installation Gui de 1-1 1 Introduction This chapter provides a functional overview of the Redundant Pow e r System (RPS), which includes the following: RPS Overview The RPS provides a si mple and e conomical solution for pro viding ? ...
-
Enterasys C2RPS-SYS - page 18
RPS Overview 1-2 Introduction C2RPS-CHAS8 Chassis The chassis is a an eight ‐ slot frame with out AC power connections or electronics. The chassis can be installed in a standar d 19 ‐ inch rack and populated with up to eight PSMs. ...
-
Enterasys C2RPS-SYS - page 19
RPS Overview SecureStack C 2 Installation Gui de 1-3 C2RPS-PSM Power Supply Module The PSM provides the following: •H o t sw ap capability . •O n e 12 Vdc, 150 Wa t t s of maximum ‐ continuous pow er output to a connected SecureStack C2 switch device. • ...
-
Enterasys C2RPS-SYS - page 20
RPS Deployment Strategies 1-4 Introduction RPS Deployment S trategies The RPS can be de ployed in a va r i e t y of situations with mission ‐ cr itical applications. For example: •F o r use in a voice and data netw ork where switches are connected ? ...
-
Enterasys C2RPS-SYS - page 21
Getting Help SecureStack C 2 Installation Gui de 1-5 Getting Help For additional support related to the devices or thi s document, contact Enterasys Networks us ing one of the following methods: Before contacti ng Enterasys Networks for technical support ...
-
Enterasys C2RPS-SYS - page 22
Getting Help 1-6 Introduction ...
-
Enterasys C2RPS-SYS - page 23
SecureStack C 2 Installation Gui de 2-1 2 Installation This chapter provides the installation instructions to install all the components of an RPS. To correctly install an RPS, follow the order of information listed below . Required T ools A flat ‐ ...
-
Enterasys C2RPS-SYS - page 24
Installing C2RPS-PSMs 2-2 Installation 3. P erform a visual inspection of the switch device s for any signs of physical damage. Contact Enterasys Netw orks if there are any signs of damage. Refe r to “ Getting Help ” on page 1 ‐ ...
-
Enterasys C2RPS-SYS - page 25
Installing C2RPS-PSMs SecureStack C 2 Installation Gui de 2-3 5. Proceed to “ Installi ng C2RPS ‐ CHAS8 into the Rack ” on page 2 ‐ 4 for the rack mount installati on instructions. Figure 2-1 C2RPS- PSM Inst allation Replacing an Inst alled C2RPS-PSM To replace a PSM in ...
-
Enterasys C2RPS-SYS - page 26
Installing C2RPS-CHAS8 into the Rack 2-4 Installation 3. Pull the PSM out and remove it from the chassis. 4. Repeat steps 1 through 3 for each additional PSM yo u plan to remove. To install a PSM, proceed as follows: 1. Align the ...
-
Enterasys C2RPS-SYS - page 27
Installing C2RPS-CHAS8 into the Rack SecureStack C 2 Installation Gui de 2-5 •A n amb ient temperature of betw een 5 ° C (41 ° F) and 40 ° C (104 ° F) must be maintained at the installation site with fluctuations of less than 10 ° C (18 ° F) per ...
-
Enterasys C2RPS-SYS - page 28
Connecting the PSM Cables and AC Power Cords 2-6 Installation Figure 2-2 Fastening the C2RPS-CHAS8 t o the Rack Connecting the PSM Cables and AC Power Cords The PSMs ar e connected to the SecureStack Ethernet switch devices using PSM cables. To connect the PSMs, pr oceed as ...
-
Enterasys C2RPS-SYS - page 29
Connecting the PSM Cables and AC Power Cords SecureStack C 2 Installation Gui de 2-7 5. On certain switches, an LED indicator will show that a redundant pow er supply is now in operation. . Figure 2-3 C2RPS-PSM Cable Figure 2-4 Power Connectors on C2RPS-PSM (rear view) Note: No cha ...
-
Enterasys C2RPS-SYS - page 30
Connecting the PSM Cables and AC Power Cords 2-8 Installation Figure 2-5 C2RPS-PSM Cable and AC Power Cord Co nnections 1 Switch device 4 Switch device Redundant Powe r Supply connector 2 PSM cable 5 AC power cord (type varies depending on country) 3 PSM Redundant Power Su pply connector 6 AC power outlet with ground connection (type varies dependi ...
-
Enterasys C2RPS-SYS - page 31
SecureStack C2 Installation Guide A -1 A Specifications This appendix provides information about the f ollowing: Enterasys Netw orks reserves the right to change the specifications at any time without notice. C2RPS-CHAS8 Chassis S pecifications Ta b l e A ‐ 1 provides ...
-
Enterasys C2RPS-SYS - page 32
C2RPS-PSM Specifications A-2 Specifications C2RPS-PSM Specifications Refer to Ta b l e A ‐ 2 for the input/outpu t port specifications . C2RPS-PSM Redundant Power Supply Output Connector For pin location and function, refer to Figu re A ‐ 1 and Ta b l e A ‐ 3 , respective ...
-
Enterasys C2RPS-SYS - page 33
Compliance Standards SecureStack C2 Installation Guide A -3 Compliance S t andards The C2RPS ‐ PSM meets the safety and electromagnetic compati bility (EMC) requirements listed in Ta b l e A ‐ 4 : T able A-3 C2RPS-PSM Redundant Power Supply Connector Pin Funct ions Pin Number Function 1 Ground 2 N ...
-
Enterasys C2RPS-SYS - page 34
Compliance Standards A-4 Specifications ...