Manual Bryant 187B

14 pages 0.81 mb
Download

Go to site of 14

Summary
  • Bryant 187B - page 1

    Installation Inst ructions 187B (2 - - 5 T ONS) 180B (3 TON TROPHY) EVOLUTION t SERIES 2 - - ST AGE AIR CONDITIONER WITH PURON R REFRIGERANT SAF ETY CONSIDERA TIONS Imp ro per installatio n , adju stmen t, alteratio n , serv ice, m ain tenan ce, or use ca n ca us e expl os ion, f ir e , ele c tr ic a l shoc k, or othe r condi t ions whi c h ma y ca ...

  • Bryant 187B - page 2

    2 The outdoor uni t c onta i ns sys t em ref r ige ra nt cha r ge for ope r at ion wit h AHR I r at e d indoor unit when c onne ct e d by 15 ft. (4.57 m) of field - - sup p lied o r factory accesso ry tu bi ng . Fo r p ro p er unit oper a ti on, c heck r e fr ige rant c har ge us ing cha r ging inf or ma ti on loc a te d on cont rol box cove r and/ ...

  • Bryant 187B - page 3

    3 T a b le 1 – Accesso ry Usa g e ACCESS ORY REQUIRED F OR L O W --- A M B I E N T C O O L I N G APPLICA TION S (Below 5 5 ° F/12.8 _ C) REQUIRED FOR LON G LINE APPLICA TION S* REQUIRED FOR SEA COAST APPLICA TION S (W ithi n 2 mil e s/ 3.22 km) Compressor Star t Assist Kit No Ye s No Crank case H e ater Standard Standard St andard Evapo rator Fr ...

  • Bryant 187B - page 4

    4 Refer to Fig . 3 an d i nstall filter d rier as fo llo ws: 1. Bra ze 5- - i n. li quid tube t o the i ndoor coi l . 2. Wrap filter drier with dam p clo th. 3. B raze filter d rier to a bove 5 - -in. (127 mm) li quid tube . Flow a rr ow must poi nt tow ar ds i ndoor coi l. 4. C o nn ect an d b raze liqu id refrig erant tu b e to the filter d rier ...

  • Bryant 187B - page 5

    5 Final W iring Ch eck IMPOR T ANT : Che c k fa c tor y wi ri ng and fi el d wi re connec t ions to ensu re term in ation s are secured p ro perly. Ch eck w ire ro utin g to ensu re w ires are no t in con tact w ith tub in g , sh eet metal, etc. C o m p r e s s o rC r a n k c a s eH e a t e r Wh en eq ui pp ed w ith a crankcase heater, f urn ish p ...

  • Bryant 187B - page 6

    6 Commu ni cati on an d Sta tus Fu n ction L i gh ts For Evolution Control Only , Gree n commu n ication s (COMM) Ligh t Gr ee n LED (COMM Light) A gre en LED (COMM l ight ) on the out door boa rd ( s ee Fig. 6) ind icates successfu l com mu n icatio n with th e oth er system produc t s. The gr ee n LED wil l re ma in OFF until communi c at ions i ...

  • Bryant 187B - page 7

    7 UTILITY RELAY * UTILITY SIGNAL OPEN RELAY * SUPPLIED BY UTILITY PROVIDER MODEL PLUG LLS Liquid Line Solenoid MODEL PLUG A06526 Fig. 6 - - 2- -Stage Contr ol Board Evolution Contr olled Low Ambient Cooling This uni t is c a pabl e of low ambi e nt cool ing dow n to 0 _ F (- - 17.78 _ C) wit hout a kit - - ONL Y when usi ng Evoluti on c ontr ol. A ...

  • Bryant 187B - page 8

    8 Fina l Che cks IMPOR T ANT : Bef ore l e avi ng job, be sur e t o do the fol low ing: 1. E n su re that all wirin g is rou ted aw ay fro m tu b in g and sheet me ta l e dges t o pre vent r ub- -through or wi re pi nc hing. 2. Ensur e tha t a ll wir ing and tubing is se cur e in unit bef ore add in g p an els and cov ers. Secu rely fasten all pan ...

  • Bryant 187B - page 9

    9 TROUBLES HOOTING If the co m presso r fails to o p erate with a coo lin g call, T ab le 4 can b e use d t o ver i fy i f t he re is any da ma ge to t he compr e ss or windi ngs ca us ing s ys te m ma lf unc ti on. T able 4 – W indi ng Res is t ance Winding Windin g resistance at 70 _ F + / --- 2 0 _ F (21.11 _ C + / - - - 11.11 _ C) 187B024 187 ...

  • Bryant 187B - page 10

    10 cuto u t trip s fo r th ree con secu tiv e cycles, then un it op eration is loc ke d out for 4 hours a nd the appr opr ia t e fa ult c ode i s dis pl aye d. No 230V at Compre ssor If t he compr es s or volt a ge is not se nse d when the com pre s sor shoul d be st ar ti ng, t he appr opri a te cont a ct or ma y be stuc k open or the r e is a wi ...

  • Bryant 187B - page 11

    11 OA T Therm istor must be locked in pla ce with spherical nib end facing towards the front of th e contr ol box Fig. 8 - - Outdoor Ai r The rmi s tor ( OA T) Att achm ent OCT Therm istor must b e secured tig ht on the liquid tu be. Fig. 9 - - Out door Coil The rm is tor ( OCT) At tac hme nt T able 6 – TROUBLESHOOTING OPERA TION FAU LT AMBER LED ...

  • Bryant 187B - page 12

    12 T h e r m i d i s t a t M o d e l s T 6 --- P R H 0 1 --- A & T 6 --- N R H 0 1 --- A w/ VS Fan C o il & 2 - - - Stage Air C on dit ion er T h e r m i d i s t a t M o d e l T 6 --- P R H 0 1 --- A & T 6 --- N R H 0 1 --- A w/ V S Fur n a ce & 2 - - - S ta ge Air C on dit ion e r RVS/Heat Stage 2 O/W2/B Heat Stage 1 W/W 1 Compress ...

  • Bryant 187B - page 13

    13 PURON R (R- -410A) REFRIGERANT QUI CK REFERENCE GUIDE S Pu ro n refrigeran t o p erates at 50 - - 70 p ercen t hig h er p ressu res than R - - 2 2 . Be su re th at serv icing eq u ip men t an d rep lacem en t com ponent s ar e de s igne d t o oper a te wit h Pur on re f ri ger a nt S Puron re f ri ger a nt cyl i nder s a re r ose c ol ore d. S R ...

  • Bryant 187B - page 14

    14 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. E 2010 Bryan t Heating & Cooling S ystem s D 7310 W . Morris St . D Indianapolis , IN 46231 Prin ted in U.S .A. Edition Date: 02/10 Replaces : New Catal og No . II180 - - - 187B - - - 01 187B / 18 ...

Manufacturer Bryant Category Air Conditioner

Documents that we receive from a manufacturer of a Bryant 187B can be divided into several groups. They are, among others:
- Bryant technical drawings
- 187B manuals
- Bryant product data sheets
- information booklets
- or energy labels Bryant 187B
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bryant 187B.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bryant 187B, service manual, brief instructions and user manuals Bryant 187B. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bryant 187B.

Similar manuals

A complete manual for the device Bryant 187B, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bryant 187B by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bryant 187B.

A complete Bryant manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bryant 187B - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bryant 187B, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bryant 187B, that we can find in the current document
3. Tips how to use the basic functions of the device Bryant 187B - which should help us in our first steps of using Bryant 187B
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bryant 187B
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bryant 187B in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bryant 187B?

Use the form below

If you did not solve your problem by using a manual Bryant 187B, ask a question using the form below. If a user had a similar problem with Bryant 187B it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)