Manual Philips Avent SCF292

17 pages Not applicable
Download

Go to site of 17

Summary
  • Philips Avent SCF292 - page 1

    1 When using electrical products, especially when children are present, basic saf ety precautions should always be follo wed, including the follo wing. READ ALL INSTR UCTIONS BEFORE USING Y OUR PHILIPS A VENT ISIS iQ UNO BREAST PUMP . W ARNING – T o reduce the risk of fire, electr ocution, or other personal injury: • ISIS iQ UNO is intended f o ...

  • Philips Avent SCF292 - page 2

    2 All you need to assemble and use ISIS iQ UNO is shown here. If any of the parts are missing, or if you have any questions, please contact Customer Ser vices (see back page f or details). 3 Battery Pack Only the following batteries are compatible w ith the ISIS iQ UNO Battery Pack: Duracell Ultra M3, Duracell Plus, Energizer Ultra Plus, Duracell A ...

  • Philips Avent SCF292 - page 3

    4 Please take a f ew minutes to read thr ough this entire instruction leaflet befor e using your Philips A VENT ISIS iQ UNO for the first time. PLEASE SA VE THESE INSTRUCTIONS . Unless advised otherwise by your health pr ofessional it is best to wait until your br eastf eeding routine is established before expr essing – usually around 4 weeks. Co ...

  • Philips Avent SCF292 - page 4

    Need Help? Contact Customer Services (see back page for details) 5 Before you use your breast pump f or the first time and every time before use, you must disassemble and clean the par ts as described opposite. Disassembling ISIS iQ UNO 2 1 Disassembly If you ha ve alr eady used your ISIS iQ UNO , turn the pump off by pressing and holding do wn the ...

  • Philips Avent SCF292 - page 5

    HELPFUL TIP! The Philips A VENT Electronic, Electric and Micr owa ve Steam Sterilisers are designed to hold the washable components of the ISIS iQ UNO and the entire ISIS Manual Breast Pump . 6 Clean with a damp cloth when necessary: These components DO NO T come into contact with your breast milk. C A UTION: NEVER PUT THE CONTROL HANDLE, BA TTER Y ...

  • Philips Avent SCF292 - page 6

    Parts you will need f or steps 1-4: White valve Silicone diaphragm with stem Let-down Massage Cushion White stand Pump body Milk container 7 Before assembling, make sure that your hands ar e clean and you have correctly washed and sterilised the pump (see ‘Cleaning and Sterilising ISIS iQ’ on pag e 6). Also check that none of the pump component ...

  • Philips Avent SCF292 - page 7

    Need Help? Contact Customer Services (see back page for details) 8 T o ensure that the pump is completely stable, you can use the stand with the 125ml/4oz milk container. Assembling the pump body of ISIS iQ UNO 2 4 Fit the clear silicone diaphragm with stem into the pump body . Ensure a perfect seal around the rim by pr essing down with your finger ...

  • Philips Avent SCF292 - page 8

    Need Help? Contact Customer Services (see back page for details) 9 Parts you will need f or steps 5-7: Batter y pack Mains power lead Assembled pump body (see pages 7-8) Connecting the Electr onics of ISIS iQ UNO 5 Firmly push the control handle onto the pump body so that it sits securely on top of the silicone diaphragm. Control handle 9219-iQUNO_ ...

  • Philips Avent SCF292 - page 9

    HELPFUL TIP! Batteries will last for appr oximately 6 hours. The light on the control handle will displa y a continuous RED pulsing flash to warn you when it is time to r eplace them. There will be enough pow er for appro ximately 1 more pumping session, with no drop-off in performance, before the pump s witches itself off. 10 i Connecting the Elec ...

  • Philips Avent SCF292 - page 10

    Using a breast pump tak es practice. Y ou ma y need to make se veral attempts befor e you succeed, but because ISIS iQ UNO is so simple and comfortable to use, you will soon get used to expressing milk. 1. Choose a quiet time when you’ re not rushed and unlikel y to be disturbed. 2. Having your baby or a photogra ph of your baby nearby can help e ...

  • Philips Avent SCF292 - page 11

    HELPFUL TIP! Before you begin pumping, make sure that you have corr ectly washed, ster ilised and assembled the pump. Consult the ‘Hints to help you succeed’ opposite for tips on stim ulating let-down and milk flow . W ash your hands thoroughly and mak e sure your breasts are clean. Relax in a comf or table chair and lean slightly forwar d so t ...

  • Philips Avent SCF292 - page 12

    Need Help? Contact Customer Services (see back page for details) Expressing with ISIS iQ UNO 4 3 Initiate let-down: T o encourage let-down, lightly press the handle in a wa y that feels comfortable and similar to your baby’ s initial rapid suckling action. The petals on the Let-down Massage Cushion will flex in and out around the ar eola, creatin ...

  • Philips Avent SCF292 - page 13

    CONSUL T THE GUIDELINES FOR STORING EXPRESSED BREAST MILK ON PA GE 17 5 7 6 Changing or ending your automated pumping session: T o change your pumping rh ythm at any time, press the contr ol button to rev ert to manual control (solid GREEN light) and set a ne w pattern. T o end your pumping session, press the contr ol button to rev ert to manual co ...

  • Philips Avent SCF292 - page 14

    Using your ISIS iQ UNO as a ma n ual breast pump Pump cover Handle ISIS Manual Breast Pump – parts guide Y our ISIS iQ UNO can also be used as a manual pump. In this case, you simply need to r eplace the control handle with the manual handle and pump cover included in a separate bag. p q But this time: p q Assembling your ISIS Manual Br east Pump ...

  • Philips Avent SCF292 - page 15

    Need Help? Contact Customer Services (see back page for details) Before you begin pumping, make sure that you have corr ectly washed, sterilised and assembled the ISIS Manual Breast Pump. Consult the ‘Hints to help you succeed’ section on page 11 for tips on stimulating let-down and milk flo w.W ash your hands thoroughly and mak e sure your bre ...

  • Philips Avent SCF292 - page 16

    Philips A VENT products ar e interchangeable, so you can expr ess, store and feed with the same container , preserving valuable nutrients that can get lost if breast milk is transfer red. After expressing milk into an A VENT Br east Milk Container , insert a sealing disc into the screw ring and twist onto the container . T o feed, just replace the ...

  • Philips Avent SCF292 - page 17

    T echnical Specifications ° Mains Input V oltage 100 - 240 V A C ° Mains Input Frequency 50 - 60 Hz ° Supply voltage fluctuations not exceeding +/- 10% of the nominal voltage ° Ambient T emperature range: +10˚C to +40˚C ° Atmospheric Pressure: 700 to 1060hPa ° Equipment rated for continuous operation ° Maximum speed at maximum vacuum is 60 ...

Manufacturer Philips Category Breast pump

Documents that we receive from a manufacturer of a Philips Avent SCF292 can be divided into several groups. They are, among others:
- Philips technical drawings
- Avent SCF292 manuals
- Philips product data sheets
- information booklets
- or energy labels Philips Avent SCF292
All of them are important, but the most important information from the point of view of use of the device are in the user manual Philips Avent SCF292.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Philips Avent SCF292, service manual, brief instructions and user manuals Philips Avent SCF292. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Philips Avent SCF292.

Similar manuals

A complete manual for the device Philips Avent SCF292, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Philips Avent SCF292 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Philips Avent SCF292.

A complete Philips manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Philips Avent SCF292 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Philips Avent SCF292, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Philips Avent SCF292, that we can find in the current document
3. Tips how to use the basic functions of the device Philips Avent SCF292 - which should help us in our first steps of using Philips Avent SCF292
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Philips Avent SCF292
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Philips Avent SCF292 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Philips Avent SCF292?

Use the form below

If you did not solve your problem by using a manual Philips Avent SCF292, ask a question using the form below. If a user had a similar problem with Philips Avent SCF292 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)