  • Empire Products RH-25-6 - page 1

    Page 1 12821-2-0903 VENTED ROOM HEA TER MODELS RH-25-6 RH-35-6 EFFECTIVE DA TE SEPTEMBER 2003 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL WARNING: If the information in this manual is not followed exactly , a fir e or explosion may result causing pr operty damage, personal injury or loss of life. — Do not stor e or use gasoline or other flam ...

  • Empire Products RH-25-6 - page 2

    Page 2 12821-2-0903 SECTION PAGE Important Safety Information ................................................................................................... .................. 3 Safety Information for Users of LP Gas ......................................................................................... ............ 4 Introduction .......... ...

  • Empire Products RH-25-6 - page 3

    Page 3 12821-2-0903 • Due to high temperatures, the room heater should be located out of traffic and away from furniture and drap- eries. • Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. • Young children should be carefully supervised when they are in ...

  • Empire Products RH-25-6 - page 4

    Page 4 12821-2-0903 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Sometimes other odors in the area ma ...

  • Empire Products RH-25-6 - page 5

    Page 5 12821-2-0903 INTRODUCTION Introduction Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installa- tion of a vented room heater. Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty ...

  • Empire Products RH-25-6 - page 6

    Page 6 12821-2-0903 Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Tubing, Type L (Feet) Inside Diameter Outside Diameter Nat. L.P. Nat. L.P. 0-10 1/2" 3/8" 1/2" 3/8" 1.3 cm 1.0 cm 1.3 cm 1.0 cm 10-40 1/2" 1/2" 5/8" 1/2" 1.3 cm 1.3 cm 1.6 cm 1.3 cm 40-100 1/2" 1/2" 3/4" 1/2" 1. ...

  • Empire Products RH-25-6 - page 7

    Page 7 12821-2-0903 CLEARANCES Clearances: When facing the front of the room heater the mini- mum clearances to combustible construction (material) are the following: Right side 6 inches (152mm). Left side 6 inches (152mm). Recommend 18 inches (457mm) on left side for servicing. Do not install in alcove or closet. No horizontal projection above hea ...

  • Empire Products RH-25-6 - page 8

    Page 8 12821-2-0903 VENT SAFETY SHUTOFF SYSTEM This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system. Warning: Operation of this heater, when not connected to a prop- erly installed and maintained venting system or tamper- ing with the vent safety shutoff system, can result in carbon m ...

  • Empire Products RH-25-6 - page 9

    Page 9 12821-2-0903 1. STOP! Read the safety information to the left of this label. 2. Set thermostat to lowest setting. 3. Turn off all electric power to the appliance. (If applicable) 4. Remove access panel (front panel). 5. Push in gas control knob slightly and turn clockwise to “OFF”. Do not force. 6. Wait ten (10) minutes to clear out any ...

  • Empire Products RH-25-6 - page 10

    Page 10 12821-2-0903 PILOT FLAME CHARACTERISTICS The correct flame will be almost horizontal, blue and will extend past the thermocouple 1/4" (6mm). The flame will surround the thermocouple just below the tip. On Propane (LP-gas) slight yellow might occur where the pilot flame and the burner flame meet. Natural gas pilots require adjusting whe ...

  • Empire Products RH-25-6 - page 11

    Page 11 12821-2-0903 To Remove Main Burner 1. Disconnect the thermocouple and pilot supply line at the pilot burner. 2. Unscrew the nut on the orifice fitting union. Orifice fitting is threaded into the main burner. 3. Remove screw on each side of the main burner and lift out. To Remove Main Burner Orifice 1. Unscrew the nut on the orifice fitting ...

  • Empire Products RH-25-6 - page 12

    Page 12 12821-2-0903 INDEX PART NO. NUMBER DESCRIPTION INDEX PART NO. NUMBER DESCRIPTION 1 R-6096 Knob & Adaptor Set 2 11700 Control Rod Bracket 3 R-2706 ECO Switch 4 R-926 Cable Assembly 5 11699 Control Rod 6 R-6104 Gas Valve (LPG) 6 R-6103 Gas Valve (Nat) 7 11697 Valve Bracket 8 RH-705 Casing Side 9 RH-708 Air Inlet Baffle 10 P-86-37 Main Bur ...

  • Empire Products RH-25-6 - page 13

    Page 13 12821-2-0903 P AR TS VIEW ...

  • Empire Products RH-25-6 - page 14

    Page 14 12821-2-0903 DRB-1 For V ented Room Heaters Models RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) Dir ect V ent W all Furnaces DV -25-(1, 2)SG and DV -35-(1, 2)SG Installing Optional DRB-1 Blower 1. For RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) , remove casing front. 1. For DV-25-(1, 2)SG and DV-35-(1, 2)SG , remove casing front and ...

  • Empire Products RH-25-6 - page 15

    Page 15 12821-2-0903 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1 , if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] pl ...

  • Empire Products RH-25-6 - page 16

    Page 16 12821-2-0903 SER VICE NOTES Empire Comfort Systems, Inc. Nine Eighteen F reeburg A ve. Belle ville, Illinois 62220-2623 PH: 1-618-233-7420 PH: 1-800-851-3153 F AX: 1-618-233-7097 F AX: 1-800-443-8648 E-MAIL: info@empirecomf or t.com WEB SITE: www .empirecomf or t.com ...

Manufacturer Empire Products Category Electric Heater

Documents that we receive from a manufacturer of a Empire Products RH-25-6 can be divided into several groups. They are, among others:
- Empire Products technical drawings
- RH-25-6 manuals
- Empire Products product data sheets
- information booklets
- or energy labels Empire Products RH-25-6
All of them are important, but the most important information from the point of view of use of the device are in the user manual Empire Products RH-25-6.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Empire Products RH-25-6, service manual, brief instructions and user manuals Empire Products RH-25-6. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Empire Products RH-25-6.

A complete manual for the device Empire Products RH-25-6, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Empire Products RH-25-6 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Empire Products RH-25-6.

A complete Empire Products manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Empire Products RH-25-6 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Empire Products RH-25-6, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Empire Products RH-25-6, that we can find in the current document
3. Tips how to use the basic functions of the device Empire Products RH-25-6 - which should help us in our first steps of using Empire Products RH-25-6
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Empire Products RH-25-6
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Empire Products RH-25-6 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Empire Products RH-25-6?

Use the form below

If you did not solve your problem by using a manual Empire Products RH-25-6, ask a question using the form below. If a user had a similar problem with Empire Products RH-25-6 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)