Manual Lux Products P521Ua

30 pages 0.48 mb
Download

Go to site of 30

Summary
  • Lux Products P521Ua - page 1

    CAUTIONS AND W ARNINGS . . . . . . . . . . 2 SYSTEM COMP A TIBILITY . . . . . . . . . . . . 3 FEA TURES . . . . . . . . . . . . . . . . . . . . . . . 4 TOOLS YOU MA Y NEED . . . . . . . . . . . . . . 4 MOUNTING LOCA TION . . . . . . . . . . . . . . 5 REMOVE OLD THERMOST A T . . . . . . . . . . 5 INST ALL THERMOST A T BASE . . . . . . . . . 6 WIRING ...

  • Lux Products P521Ua - page 2

    2 • This thermostat requires batteries to opera te and failure or sub-standard performance of the batteries may impair or prevent the correct operation of the thermostat. Use Duracell ® or Energizer ® alkaline batteries ONL Y for all LUXPRO thermostats requiring batteries. BE SURE TO CHANGE THE BA TTERIES A T LEAST ONCE A YEAR, or whenever you ...

  • Lux Products P521Ua - page 3

    HOLD S E T R U N D AY/ T IM E T EM P P RO G A IR FI LT ER T E MP E RAT U RE H E AT O FF C OO L F A N A U TO O N E ME R N EX T LCD Display Screen P521Ua UP , DOWN and HOLD Buttons Set Slide Switch Fan Mode Switch System Mode Switch The electrical rating for this thermostat is 1.5 Amps per terminal, with a maximum total combined load of 3.0A for all ...

  • Lux Products P521Ua - page 4

    • 1 or 2-Heat / 1-Cool, 5/2-day programming • Universal Compatibility for all system types • Weekdays and Weekends can be programmed separately • Exclusive LUX ® Speed Slide T M for easy programming • User -selectable periods per day (2 or 4) • User -selectable programmable or non-programmable operation • LuxLight ® EL (Electro-Lumi ...

  • Lux Products P521Ua - page 5

    On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, please follow these general guidelines: 1. Mount the thermostat on an inside wall, about 5 ft. (1.5m) above the floor . 2. Do not locate the thermostat where air circulation is poor such as in a ...

  • Lux Products P521Ua - page 6

    1. Strip wire insulation leaving only 3/8 in. (9.5mm) bare wire ends, and clean off any corrosion present. 2. F ill the wall opening with non-combustible insulation to prevent drafts from affecting the thermostat’ s normal opera tion. 3. Separate new thermostat housing using your thumb and index finger . Provide pressure in opposite directions to ...

  • Lux Products P521Ua - page 7

    WIRING DIAGRAM NOTES: (Important, please read all notes before connecting wires) • If the information provided in the following wiring diagrams does not clearly represent or match your system, please refer to the “TECHNICAL ASSIST ANCE” section of this manual, and contact us before removing any of your existing thermostat wiring. • All of t ...

  • Lux Products P521Ua - page 8

    8 #1 CONVENTIONAL: HEA TING ............................................................9 1-ST AGE OR 2-ST AGE 2 , 3 , 4 , 5 W I R E S #2 CONVENTIONAL: HEA TING .......................................................... 1 0 3-WIRE ZONE V AL VE 3, 4 WIRES #3 CONVENTIONAL: COOLING .......................................................... 1 1 1-ST AG ...

  • Lux Products P521Ua - page 9

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC W1 4 W X F G B* W2 RH V R W1 A W2 O B C G Y RC RH 1-ST AGE OR 2-STAGE, HEA TING ONL Y (INCLUDING MILLIVOL T) (2-WIRE HEA T USE “RH” & “W1”) Factory RH-RC Jumper Wire Installed #1 2, 3, 4, 5 WIRES C H EATE R S T AG E 1 S T AG E 2 FAN SYSTEM 24V TRANSF ...

  • Lux Products P521Ua - page 10

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC X B* C RH V R W1 4 W A W1 A W2 O B C G Y RC RH HOT WA TER HEA TING ONL Y (WITH A 3-WIRE ZONE V AL VE) Factory RH-RC Jumper Wire Installed #2 3, 4 WIRES SYSTEM 24V TRANSFORMER SYSTEM COMMON OPEN = Heat On CLOSE = Heat Off 3 -W I RE ZO N E VA LVE O PE N C LOS E O ...

  • Lux Products P521Ua - page 11

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC X F G Y1 6 Y B* RC V R W1 A W2 O B C G Y RC RH 1-ST AGE, COOLING ONL Y Factory RH-RC Jumper Wire Installed #3 C FAN SYSTEM 24V TRANSFORMER SYSTEM COMMON 3, 4 WIRES O P T I O N A L A IR CO N DI T IO N ER 11 ...

  • Lux Products P521Ua - page 12

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC RH RC V R Y1 6 Y F G X W1 4 W B* W1 A W2 C G O B Y RC RH CONVENTIONAL (NON HEA T PUMP) 1-ST AGE HEATING AND 1-ST AGE COOLING Factory RH-RC Jumper Wire Installed #4 C FAN SYSTEM 24V TRANSFORMER SYSTEM COMMON H EATE R AIR CONDITIONER 4, 5 WIRES O P T I O N A L 12 ...

  • Lux Products P521Ua - page 13

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC W2 RH RC V R Y1 6 Y F G X W1 4 W B* W1 A W2 C G O B Y RC RH CONVENTIONAL (NON HEA T PUMP) 2-ST AGE HEATING AND 1-ST AGE COOLING Factory RH-RC Jumper Wire Installed #5 C FAN SYSTEM 24V TRANSFORMER SYSTEM COMMON AIR CONDITIONER 5, 6 WIRES O P T I O N A L H EATE R ...

  • Lux Products P521Ua - page 14

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC X B* C R V RH R V RC Y1 6 Y F G W1 4 W W1 A W2 O B C G Y RC RH CONVENTIONAL (NON HEA T PUMP) 1-STAGE HEA TING AND 1-ST AGE COOLING WITH TWO SEPARA TE 24V TRANSFORMERS Factory RH-RC Jumper Wire REMOVED #6 FAN H E A T 2 4 V T RA N S FO R ME R COOL 24V T RA N S FO ...

  • Lux Products P521Ua - page 15

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC O X F G Y1 6 Y B* RC V R W1 A W2 O B C G Y RC RH SINGLE-ST AGE HEAT PUMP SYSTEM WITH NO AUX OR EMERGENCY HEA T #7 C FAN SYSTEM 24V TRANSFORMER SYSTEM COMMON 4, 5 WIRES O P T I O N A L H EAT P U MP REVERSING VALVE ** Use “O” or “B” T erm inals, Never B ot ...

  • Lux Products P521Ua - page 16

    NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRA Y TERMINAL LETTERS ARE BRAND SPECIFIC CUSTOMER INST A LLED Y -W1 Jumper Wire X B* C W3 W W2 O F G Y1 6 Y RC V R W1 A W2 O B C G Y RC RH 2-HEA T / 1-COOL, HEAT PUMP SYSTEM WITH AUX AND EMERGENCY HEA T Factory RH-RC Jumper Wire Installed #8 FAN SYSTEM 24V TRANSFORMER SYSTEM COMMON 5, 6 WIRES H EAT P U ...

  • Lux Products P521Ua - page 17

    INST ALL BA TTERIES INTO THERMOST A T : Install two brand new Energizer ® o r DURACELL ® “AA ” size alkaline (only) batteries, into the thermosta t’ s battery compartment. Ensure the batteries are installed in the proper direction. GAS / ELEC CIRCUIT BOARD OPTION (“G” TERMINAL FAN OPERA TION): This setting is a plastic shorting cap call ...

  • Lux Products P521Ua - page 18

    with or without a demand for heating or cooling, even when the System Mode switch is in the OFF position. NOTE: The Fan Mode switch only works if your system provides a wire for the thermostat’ s “G” wire terminal, to control a blower fan. The Fan Mode switch has no effect in systems that do not have a blower fan (such as a hot wa ter radiato ...

  • Lux Products P521Ua - page 19

    Setup options for how the thermostat will function, along with choosing your particular system type, are performed using a menu on the display screen. TO ACCESS THE SETUP MENU: Move the System Mode switch into the OFF position, and then hold down the EMER button for approximately 5 seconds until the screen changes. The menu will always start with i ...

  • Lux Products P521Ua - page 20

    ITEM #07 (DLA Y = DELA Y TIME): [5, default] Thermostat waits 5 minutes before turning the system back on after it was last run. This internal delay prevents rapid cycling and provides equipment protection. The 5 minute setting is fine for most applications. [2] Same operation as above but reduced to 2 minutes between state changes. ITEM #08, #09, ...

  • Lux Products P521Ua - page 21

    SET D A Y AND TIME: Place the Set Slide Switch into the DA Y/TIME position. With the day flashing, press UP or DOWN to set the day of the week. Press NEXT and the clock time will start flashing. Use UP or DOWN to set the time, making sure the AM/PM indication is correct. Holding the UP or DOWN buttons will make the clock digits scroll rapidly . Ret ...

  • Lux Products P521Ua - page 22

    characteristics, you should refer to your heat pump literature to determine when to disable the heat pump and run in Emergency Heat mode. In general for most heat pump systems, use Emergenc y Hea t mode whenever the outside temperature is less than 32°F (0°C) degrees. LCD DISPLA Y BACKLIGHT : The display screen is lighted to assist viewing at nig ...

  • Lux Products P521Ua - page 23

    By default, this thermostat has 4 separate program periods for both Heat and Cool mode, they are: MORN, DA Y , EVE, and NITE. Each period ends at the start time of the following period. The heat programs are set in HEA T mode, and the cool programs are set in COOL mode. NOTE: If the thermostat is configured to use only 2 periods per day instead of ...

  • Lux Products P521Ua - page 24

    TEMPERA TURE CALIBRA TION: The internal temperature sensor in this thermostat is accurately calibrated at the factor y , and in most cases alterations to this setting should not be needed. The T empera ture Calibration feature allows you to manually offset the measured temperature by as much as plus or minus 5°F (3°C) degrees from its original va ...

  • Lux Products P521Ua - page 25

    NEXT button to accept the setting. If the code you tried was not correct, the thermostat will exit and return to the Normal Run screen with no changes made. If the entered code is correct, the screen will add the word “SET” and display the current heat set temperature limit. Use the UP/DOWN buttons to adjust the maximum heat set temperature val ...

  • Lux Products P521Ua - page 26

    KEYP AD LOCKOUT : Y ou can lock the front panel buttons to prevent unauthorized tampering of your thermostat settings. NOTE: These keypad lock instructions need to be performed in a timely manner . The 4-button sequence which locks the thermostat must be entered within a 10- second timeframe, or the keypad lockout sequence will have to be entered a ...

  • Lux Products P521Ua - page 27

    TO RESET THE FIL TER USAGE COUNTER: Move the Set Slide switch to the “AIR FIL TER” position. The three small digits at the top of the screen tell you the quantity of filter days remaining. Press both the UP and DOWN buttons together , and the usage counter will return to the beginning of the value that it originally started counting from. Refer ...

  • Lux Products P521Ua - page 28

    This thermostat is powered by two “AA ” Alkaline batteries. The batteries should be replaced A T LEAST once per year to ensure reliable operation (or sooner if “LO BA TT” appears in the display screen). The batteries are located on the back of the thermostat’ s circuit board. The front portion of the thermosta t can be removed from the ba ...

  • Lux Products P521Ua - page 29

    If you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. If you require assistance, please contact our T echnical Assistance department at 856-234-8803 during regular business hours between 8:00AM and 4:30PM Eastern Standard Time, Monday through Friday . Y ou can also receive techn ...

  • Lux Products P521Ua - page 30

    Mercury is considered to be a hazardous material. If this product is replacing a thermostat that contains mercur y in a sealed tube, contact your local waste management authority for instructions regarding recycling and proper disposal. It may be unlawful in your state to place it in the trash. 30 MERCURY W ARNING AND RECYCLING NOTICE: Mt. Laurel, ...

Manufacturer Lux Products Category Thermostat

Documents that we receive from a manufacturer of a Lux Products P521Ua can be divided into several groups. They are, among others:
- Lux Products technical drawings
- P521Ua manuals
- Lux Products product data sheets
- information booklets
- or energy labels Lux Products P521Ua
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lux Products P521Ua.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lux Products P521Ua, service manual, brief instructions and user manuals Lux Products P521Ua. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lux Products P521Ua.

A complete manual for the device Lux Products P521Ua, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lux Products P521Ua by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lux Products P521Ua.

A complete Lux Products manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lux Products P521Ua - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lux Products P521Ua, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lux Products P521Ua, that we can find in the current document
3. Tips how to use the basic functions of the device Lux Products P521Ua - which should help us in our first steps of using Lux Products P521Ua
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lux Products P521Ua
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lux Products P521Ua in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lux Products P521Ua?

Use the form below

If you did not solve your problem by using a manual Lux Products P521Ua, ask a question using the form below. If a user had a similar problem with Lux Products P521Ua it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)