Manual Pentair MPE

16 pages 1.52 mb
Download

Go to site of 16

Summary
  • Pentair MPE - page 1

    D YN A-PRO TM CENTRIFUGAL PUMPS WITH INTEGRAL TRAP O W N E R’ S M A N U A L INST ALLA TION, OPERA TION & P ARTS Series MPRA, MPEA, and MPE See P age 3 for Model Numbers Pentair Water Pool and Spa, Inc. Sanford, N.C., Moor p ark, CA, USA Ontario, Canada Herentals, Belgium S771 (Rev. B 2 / 8 /0 8 ) This manual should be furnished to the end use ...

  • Pentair MPE - page 2

    2 T echnical Suppor t Sanford, North Carolina (8 A.M to 5 P.M.) Phone: (800) 831-7133 Moorpark, California (8 A.M to 5 P.M.) Phone: (800) 831-7133 Fax: (80 0 ) 284-4151 Websites: visit www.pentairpool.com and staritepool.com © 200 8 Pentair Water Pool and Spa, Inc. All rights reserved. This document is subject to change without notice. 1620 Hawkin ...

  • Pentair MPE - page 3

    3 ‘MPRA ’, ‘MPEA ’ & ‘MPE’ SERIES PUMPS WITH TRAP To avoid unneeded service calls, prevent possible in- juries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! The Sta-Rite ‘MPRA’, ‘MPEA’ & ‘MPE’ Series Self-priming Centrifugal pump: • Is designed for use with swimming pools or as a cen- trifugal pum ...

  • Pentair MPE - page 4

    4 1. Do not connect system to a high pressure or city water system. 2. Use equipment only in a pool or spa installation. 3. Trapped air in system can cause explosion. BE SURE all air is out of system before operating or testing equipment. Before pressure testing, make the following safety checks: • Check all clamps, bolts, lids, and system access ...

  • Pentair MPE - page 5

    5 Allow pump suction inlet height to be as close to water level as possible. Pump will not lift water more than 10' (3m). Allow use of short, direct suction pipe (To reduce friction losses). Allow for gate valves in suction and discharge piping. Have adequate floor drainage to prevent flooding. Be protected from excess moisture. Allow adequate ...

  • Pentair MPE - page 6

    6 W ater V elocity The maximum water velocity through the suction fitting or cover for any suction outlet must not exceed 1.5 feet per second unless the outlet complies with the latest ANSI/ASME Specification for Suction Fittings For Use in Swimming Pools, Spas, Hot Tubs, and Whirlpool Bathtub Applications. In any case, do not exceed the suction fi ...

  • Pentair MPE - page 7

    7 Grounding/Bonding Install, ground, bond and wire motor according to local or National Electrical Code requirements. Permanently ground motor. Use green ground terminal provided under motor canopy or access plate (See Figure 4); use size and type wire required by code. Connect motor ground terminal to electrical service ground. Bond motor to pool ...

  • Pentair MPE - page 8

    8 T ABLE I - RECOMMENDED CIRCUIT BREAKER AND WIRING D A T A Serv. to Motor - Dist. in Ft. (M) Motor Branch CB Max Load Voltage/ 0-100' 101-200' 201-300' HP Rating Amps Amps Hz/Phase (0-30) (30-60) (60-90) MPRA SERIES – SINGLE SPEED 3/4 20/15 13.4/6.7 115/230/60/1 12/14(3/2) 10/14(5.5/2) 8/14(8.4/2) 1 20/15 15.3/7.6 115/230/60/1 12/ ...

  • Pentair MPE - page 9

    9 OPERA TION NOTICE: NEVER run pump dry. Running pump dry may damage seals, causing leakage and flooding. Fill pump with water before starting motor. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GATE VALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system. If pump is being pressure tested, ...

  • Pentair MPE - page 10

    10 For outdoor/unprotected installations: 1. Enclose entire system in a weatherproof enclosure. 2. To avoid condensation/corrosion damage, allow venti- lation; do not wrap system in plastic. 3. Use a 40% propylene glycol/60% water solution to protect pump to -50°F (-46°C). Dr aining Pump Explosion hazard. Purging the system with compressed air ca ...

  • Pentair MPE - page 11

    11 If shaft seal is worn or damaged, repair as follows: Pump D issasem bly/R emo ving Old Seal Disconnect power to pump motor. Be sure valves on suction and return piping are closed before starting work. Release all pressure by opening all vents before starting work. 1. Drain pump by removing drain plugs on bottom of pump body and trap body. 2. Be ...

  • Pentair MPE - page 12

    12 TROUBLESHOOTING GUIDE Read and understand safety and operating instruc tions in this manual before doing any work on pump! Only qualified personnel should electrically test pump motor! FAILURE TO PUMP; REDUCED CAPACITY OR DISCHARGE PRESSURE Suction leaks/lost prime: 1. Pump must be primed; make sure that pump volute and trap are full of water. S ...

  • Pentair MPE - page 13

    13 1 2 3 4 5 6 7 8 8 A 8 B See Bo x A See Bo x A 11 12 13 14 15B 15A 16 17 1 8 19 20 21 22 23 24 9 10 REP AIR P AR TS LIST D YNA-PRO™ POOL PUMP 1/2 thr ough 2-1/2 HP Models Single Speed and T wo Speed Model No. HP Motor (Key No. 1) Single Speed 115/230/60/1 MPRA6D-204L 3 / 4 A100DLL MPRA6E-205L 1 A100ELL MPRA6F-206L 1-1/2 A100FLL MPEA6D-204L 3/ 4 ...

  • Pentair MPE - page 14

    14 MPEA6G-207L MPEA6F-206L MPE6F-207L MPEAA6G-208L MPEA6D-204L MPEA6E-205L MPE6E-206L MPEA6YG-207L MPE6G-208L Key Part MPE6C-204L MPE6D-205L MPRA6F-206L MPE6YF-207L MPEAA6YG-208L No. Description Qty. MPRA6D-204L MPRA6E-205L MPRA6YF-206L MPRA6G-207 MPE6G-208L 2 Screw #10-32x1/2" 1 U30-692SS U30-692SS U30-692SS U30-692SS U30-692SS 3 Bonding Lug ...

  • Pentair MPE - page 15

    15 ...

  • Pentair MPE - page 16

    P/N S771 Rev . B 2/8/08 ...

Manufacturer Pentair Category Plumbing Product

Documents that we receive from a manufacturer of a Pentair MPE can be divided into several groups. They are, among others:
- Pentair technical drawings
- MPE manuals
- Pentair product data sheets
- information booklets
- or energy labels Pentair MPE
All of them are important, but the most important information from the point of view of use of the device are in the user manual Pentair MPE.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Pentair MPE, service manual, brief instructions and user manuals Pentair MPE. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Pentair MPE.

Similar manuals

A complete manual for the device Pentair MPE, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Pentair MPE by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Pentair MPE.

A complete Pentair manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Pentair MPE - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Pentair MPE, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Pentair MPE, that we can find in the current document
3. Tips how to use the basic functions of the device Pentair MPE - which should help us in our first steps of using Pentair MPE
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Pentair MPE
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Pentair MPE in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Pentair MPE?

Use the form below

If you did not solve your problem by using a manual Pentair MPE, ask a question using the form below. If a user had a similar problem with Pentair MPE it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)