    UNVENTED (VENT -FREE) GAS LOG HEA T ER OWNER’S OP ER A TION AND IN ST AL LA TION MANUAL Design Dynamics V entfree Mod els Also De sign-Cer ti fi ed As V ented Dec o ra tive Ap pli anc es Sav e this manual for future reference. WARNING: If the information in this man u al is not followed exactly, a fi re or explosion may result caus ing prop er ...

  • Desa VF-18N-BTB - page 2

    111826-01 For more information, visit www .desatech.com 2 T ABLE OF CONTENTS SAFETY INFORMA TION .............................................................. 2 PRODUCT IDENTIFICA TION ....................................................... 3 OPTIONAL REMO TE CONTROL A CCESSORIES ...................... 4 LOCAL CODES ............................... ...

  • Desa VF-18N-BTB - page 3

    111826-01 For more information, visit www .desatech.com 3 3 SAFETY INFORMA TION Continued PR ODUCT IDENTIFICA TION Figure 1 - Product Identifi cation 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not con vertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any ...

  • Desa VF-18N-BTB - page 4

    111826-01 For more information, visit www .desatech.com 4 LOCAL CODES Install and use heater with care. Follo w all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFP A 54 *. *A vailable from: American National Standards In sti tute, Inc. 1430 Broadway Ne w Y ork, NY 10018 National Fire ...

  • Desa VF-18N-BTB - page 5

    111826-01 For more information, visit www .desatech.com 5 5 40,000 33,000 73,000 Unusually tight construction is de fi ned as construction where: a. walls and ceilings exposed to the outside at mo sphere have a con tin u ous water vapor retarder with a rating of one perm (6 x 10 -11 kg per pa-sec-m 2 ) or less with open ings gasketed or sealed and ...

  • Desa VF-18N-BTB - page 6

    111826-01 For more information, visit www .desatech.com 6 AIR FOR COMBUSTION AND VENTILA TION Continued VENTILA TION AIR V entilation Air Fr om Inside Building This fresh air would come from an adjoining unconfi ned space. When ventilating to an adjoining unconfi ned space, you must pro vide two permanent open ings: one within 12" of the cei ...

  • Desa VF-18N-BTB - page 7

    111826-01 For more information, visit www .desatech.com 7 7 INST ALLA TION NO TICE: This heater is in tend ed for use as sup ple - men tal heat. Use this heater along with your pri ma ry heat ing system. Do not in stall this heat er as your pri- ma ry heat source. If you ha ve a central heating system, you ma y run sys tem’ s cir cu lat ing blo w ...

  • Desa VF-18N-BTB - page 8

    111826-01 For more information, visit www .desatech.com 8 Carefully follo w the instructions belo w . This will ensure safe in- stal la tion into a masonry , UL127-listed manufactured fi replace, or list ed vent-free fi re box. Minimum Clearances For Side Comb ustible Material, Side W all, and Ceiling A. Clearances from the side of the fi re pla ...

  • Desa VF-18N-BTB - page 9

    111826-01 For more information, visit www .desatech.com 9 9 INST ALLA TION Continued MANTEL CLEARANCES In addition to meeting noncom bus ti ble ma te ri al clearances, you must also meet required clearances between fi replace open ing and mantel shelf. If you do not meet the clear anc es listed below, you will need a hood. Determining Minimum Mant ...

  • Desa VF-18N-BTB - page 10

    111826-01 For more information, visit www .desatech.com 10 INST ALLING D AMPER CLAMP A CCESSOR Y FOR VENTED OPERA TION Note: When used as a vented decorativ e, ap pli ance must be installed only in a solid-fuel burning fi replace with a working fl ue and con- structed of noncombustible material. If your heater is a non-thermostatically-controlled ...

  • Desa VF-18N-BTB - page 11

    111826-01 For more information, visit www .desatech.com 11 11 INST ALLA TION Continued INST ALLA TION Installing Heater Assembly (Cont.) W ARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pres- sure regulator . W ARNING: A qualifi ed ser vice per son m ust con- nect heater to gas sup pl y . Follo w all ...

  • Desa VF-18N-BTB - page 12

    111826-01 For more information, visit www .desatech.com 12 INST ALLA TION Continued * Purchase the optional CSA design-cer ti fi ed equipment shutof f valve from your dealer . See Accessories , page 27. **Minimum inlet pressure for purpose of input adjustment. Figure 13 - Gas Connection (Remote-Ready Models Onl y) Gas Control Pipe Cap T ee Nipple ...

  • Desa VF-18N-BTB - page 13

    111826-01 For more information, visit www .desatech.com 13 13 INST ALLA TION Continued INST ALLA TION Connecting to Gas Supply (Cont.) Checking Gas Connections Figure 15 - Checking Gas Joints (pr opane/LP only) Figure 16 - Checking Gas Joints (Natural Gas Onl y) Thermostat Gas V alv e or Control V alv e Location Equipment Shutoff V alv e Propane/LP ...

  • Desa VF-18N-BTB - page 14

    111826-01 For more information, visit www .desatech.com 14 OPERA TING HEA TER OPERA TING HEA TER (REMO TE-READ Y MODELS) For Y our Safety Read Before Lighting W ARNING: If y ou do not fol low these instructions exactl y , a fi re or ex plo sion may result caus ing prop er ty damage, personal injury or loss of life . A. This appliance has a pilot w ...

  • Desa VF-18N-BTB - page 15

    111826-01 For more information, visit www .desatech.com 15 15 OPERA TING HEA TER (REMO TE-READ Y MODELS) For Y our Safety Read Before Lighting (Cont.) Lighting Instructions OPERA TING HEA TER Continued Figure 18 - Control Knob and Ignitor Button Location, Remote Ready Contr olled Remote Control 7. With contr ol knob pressed in, press and r elease i ...

  • Desa VF-18N-BTB - page 16

    111826-01 For more information, visit www .desatech.com 16 NOTICE: You must light the pilot before using the remote con trol unit. See Lighting In struc tions on pa g e 14. GHRCT A Series Operation: 2a. Press the A UTO/ON/OFF b ut ton on the hand-held re mote con trol (see Fig ure 33). The lights to the left of the button will show A UTO, ON, or OF ...

  • Desa VF-18N-BTB - page 17

    111826-01 For more information, visit www .desatech.com 17 17 BURNER FLAME P A TTERN Figure 24 sho ws correct front burner fl ame pattern. NO TICE: Do not mistake orang e fl ames with yellow tipping. Dir t or other fi ne particles are burned b y heat er , causing brief patches of orange fl ame . If front burner fl ame pattern is incorrect, as ...

  • Desa VF-18N-BTB - page 18

    111826-01 For more information, visit www .desatech.com 18 W ARNING: T urn off heater and let cool bef ore cleaning. CA UTION: Y ou m ust keep contr ol areas, b urner s, and cir cu lat ing air pas sage ways of heat er clean. In- spect these areas of heater before each use. Have heater inspected yearl y by a qual i fi ed service per - son. Heater m ...

  • Desa VF-18N-BTB - page 19

    111826-01 For more information, visit www .desatech.com 19 19 TR OUBLESHOO TING Note: All troubleshooting items are listed in order of operation. W ARNING: T urn off and un- plug heater and let cool before servicing. Only a qualifi ed ser vice person should service and repair CA UTION: Never use a wire, needle, or similar object to clean ODS/pilot ...

  • Desa VF-18N-BTB - page 20

    111826-01 For more information, visit www .desatech.com 20 TR OUBLESHOO TING Continued OBSER VED PR OBLEM One or both burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfi ring dur ing com bus tion Orange flame in burner during b urner com bus tion Slight smoke or odor during initial op- er a tion Heater produces a ...

  • Desa VF-18N-BTB - page 21

    111826-01 For more information, visit www .desatech.com 21 21 TR OUBLESHOO TING Continued W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any ap pli ance . • Do not touch any elec tri cal s witch; do not use any phone in y our build ing. • Immediately call y our gas sup plier from a neighbor’ s phone . Follow the ...

  • Desa VF-18N-BTB - page 22

    111826-01 For more information, visit www .desatech.com 22 VF-18N-PDG/VF-18N-BTB VF-24N-PDG/VF-24N-BTB Btu (V ariable) 24,000/36,000 25,000/39,000 T ype Gas Natural Gas Only Natural Gas Only Ignition Piezo Piezo Manifold Pressure 3.5" W .C. 3.5" W .C. Inlet Gas Pressure (in. of water) Maximum 10.5" W .C. 10.5" W .C. Minimum* 5.0 ...

  • Desa VF-18N-BTB - page 23

    111826-01 For more information, visit www .desatech.com 23 23 SER VICE HINTS When Gas Pressure Is T oo Low • pilot will not stay lit • burners will hav e delayed ig ni tion • heater will not produce specifi ed heat • propane/LP gas supply may be low Y ou may feel your gas pressure is too low . If so, contact your local propane/LP or natura ...

  • Desa VF-18N-BTB - page 24

    111826-01 For more information, visit www .desatech.com 24 THIS P A GE INTENTIONALL Y LEFT BLANK ...

  • Desa VF-18N-BTB - page 25

    111826-01 For more information, visit www .desatech.com 25 25 ILLUSTRA TED P AR TS BREAKDO WN REMO TE-READ Y MODELS AND REMO TE CONTROLLED MODELS VF-24N-PDG VF-24N-BTB VF-24P-PDG VF-24P-BTB ILLUSTRA TED P AR TS BREAKDOWN V ariable Manually-Controlled and Remote-ready Models VF-24N-PDG, VF-24P-PDG, VF-24N-BTB, VF-24P-BTB VF-18N-PDG, VF-18P-PDG, VF-1 ...

  • Desa VF-18N-BTB - page 26

    111826-01 For more information, visit www .desatech.com 26 P AR TS LIST This list contains replaceable parts used in your heater . When order- ing parts, follow the instructions listed under Replacement P arts on page 24 of this manual. P AR TS LIST Manual and Remote-Ready Models VF-24N-PDG, VF-24P-PDG, VF-24N-BTB, VF-24P-BTB, VF-18N-PDG, VF-18P-PD ...

  • Desa VF-18N-BTB - page 27

    111826-01 For more information, visit www .desatech.com 27 27 A CCESSORIES W ALL-MOUNT THERMOST A T SWITCH - GWMT1 (Not Shown) F or all Remote-Ready Models. The desired com fort setting can be selected on the wall ther mo stat and the log heat er will au to mat i cal ly cycle from pi lot to the heat setting selected. W ALL-MOUNT ON/OFF SWITCH - GWM ...

  • Desa VF-18N-BTB - page 28

    111826-01 For more information, visit www .desatech.com 28 • A CCESSORIES 1. Where will the product be used? ❍ Living/F amily Room ❍ Office/Warehouse ❍ Utility Shed/Outb uilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other 2. If you bought this product y ourself, did you plan to purchase this type of product bef ore going into the store? ? ...

  • Desa VF-18N-BTB - page 29

    111826-01 For more information, visit www .desatech.com 29 29 2701 S. Harbor Blvd. Santa Ana, CA. 92704 www .desatech.com P ost age Required TM ...

  • Desa VF-18N-BTB - page 30

    111826-01 For more information, visit www .desatech.com 30 NO TES ________________________________________________________________________________________________ ________________________________________________________________________________________________ __________________________________________________________________________________________ ...

  • Desa VF-18N-BTB - page 31

    111826-01 For more information, visit www .desatech.com 31 31 2701 S. Harbor Blvd. Santa Ana, CA. 92704 www .desatech.com 111826-01 Re v . A 10/03 NO T A UPC KEEP THIS W ARRANTY W ARRANTY INFORMA TION Model Serial No . Date Purchased Always specify model and serial numbers when communicating with the f actory . W e reserve the right to amend these ...

Manufacturer Desa Category Electric Heater

Documents that we receive from a manufacturer of a Desa VF-18N-BTB can be divided into several groups. They are, among others:
- Desa technical drawings
- VF-18N-BTB manuals
- Desa product data sheets
- information booklets
- or energy labels Desa VF-18N-BTB
All of them are important, but the most important information from the point of view of use of the device are in the user manual Desa VF-18N-BTB.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Desa VF-18N-BTB, service manual, brief instructions and user manuals Desa VF-18N-BTB. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Desa VF-18N-BTB.

Similar manuals

A complete manual for the device Desa VF-18N-BTB, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Desa VF-18N-BTB by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Desa VF-18N-BTB.

A complete Desa manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Desa VF-18N-BTB - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Desa VF-18N-BTB, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Desa VF-18N-BTB, that we can find in the current document
3. Tips how to use the basic functions of the device Desa VF-18N-BTB - which should help us in our first steps of using Desa VF-18N-BTB
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Desa VF-18N-BTB
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Desa VF-18N-BTB in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Desa VF-18N-BTB?

Use the form below

If you did not solve your problem by using a manual Desa VF-18N-BTB, ask a question using the form below. If a user had a similar problem with Desa VF-18N-BTB it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)