Manual Crown Boiler 32-475ECS

16 pages 1.76 mb
Download

Go to site of 16

Summary
  • Crown Boiler 32-475ECS - page 1

    D e s i g n e D t o L e a D T el: (215) 535-8900 • Fax: (215) 535-9736 • www .crownboiler .com Manufacturer of Hydronic Heating Products P .O. Box 14818 3633 I. Street Philadelphia, P A 19134 Series 32ECS Gas-Fired Natural Draft Steam or W ater Boilers INST ALLA TION SUPPLEMENT FOR: 32-380ECS 32-475ECS EQUIPPED WITH 24 VOL T CONTROL SYSTEMS W A ...

  • Crown Boiler 32-475ECS - page 2

    ...

  • Crown Boiler 32-475ECS - page 3

    I Pr oduct Description This supplement covers information not included in the standard Series 32 installation manual that is unique to the following models: 32-380WNLECS, 32-475WNLECS 32-380WNTECS, 32-475WNTECS 32-380SNLECS, 32-475SNLECS Follow the Series 32 installation instructions except where noted in this supplement. II Specications 32-380E ...

  • Crown Boiler 32-475ECS - page 4

    VII V enting Refer to installation manual. V ent sizing for the 32-380ECS should always be done in accordance with the National Fuel Gas Code. A vent damper can be installed on any 32-380ECS or 32-475ECS equipped with a 24 volt control system except for those with tankless heaters. If a vent damper is installed, the following components are require ...

  • Crown Boiler 32-475ECS - page 5

    W ARNING All wiring and grounding must be done in accordance with the authority having jurisdiction or , in the absence of such CAUTION Make sure that damper and BVS harnesses are secured so that they do not come in contact with draft hood or steam piping. XI Contr ol System W iring W ire the boiler in accordance with the following instructions rat ...

  • Crown Boiler 32-475ECS - page 6

    “BURNER” “BURNER” TH TR + ROBERTSHAW 7000DERHC GAS V AL VE VENT DAMPE R (NOTE 2) NOTE 2 LESS VENT DAMPER 2. ON BOILERS LESS VENT DAMPER, DAMPER HARNESS NOT USED. RED AND BLUE LEADS ARE JUMPED TOGETHER USING RED JUMPER WIRE. RD RD RD ALARM ALARM 2 (NOTE 2) 2. WHEN DAMPER IS NOT USED, DAMPER HARNESS IS REPLACED WITH JUMPER PLUG. PILOT V ALVE ...

  • Crown Boiler 32-475ECS - page 7

    Sequence of Operation - Steam Boiler 1) When the boiler is ener gized, 24 volts is immediately applied to terminals “1” (blue) and “4” (yellow) on the vent damp - er . Assuming that there is no call for heat, and that the damper switch is in the “automatic” position, the damper will close. On boilers equipped with Hydrolevel CG400A prob ...

  • Crown Boiler 32-475ECS - page 8

    2 HIGH LIMIT LOW LIMIT HONEYWELL L8124E TH TR + ROBERTSHAW 7000DERHC GAS VAL VE PILOT VAL VE MAIN VAL VE RD RD RD/YE RD RD/YE ALARM ALARM Figure C: W ater Boiler Wiring (W ith T ankless Heater) Figure D: Steam Boiler Control Installation 6 ...

  • Crown Boiler 32-475ECS - page 9

    equipped with a reset button which must be pressed to restore normal burner operation. An open blocked vent switch is indicative of a problem with the vent system. If the blocked vent switch opens, the cause of the venting problem must be found and corrected by a qualied gas service technician before the blocked vent switch is reset. Sequence of ...

  • Crown Boiler 32-475ECS - page 10

    Figure F: W ater Boiler Contr ol Installation (Less T ankless Heater V ersion Shown) Figure E: Blocked V ent Switch Installation 8 ...

  • Crown Boiler 32-475ECS - page 11

    6) Once the ignition module detects the presence of a pilot ame, voltage is applied across the main valve (terminals “MV” and “MV/PV”), opening the valve and establishing main ame. 7) The way in which the ignition module handles failure to establish pilot or the loss of an already established pilot depends upon the exact ignition modu ...

  • Crown Boiler 32-475ECS - page 12

    380 475 380 475 I A PART # (STANDARD) 310000 310001 310002 3110053 3110063 310405 310406 311026 311020 311010 310400 311027 311028 311031 1 EA. 1 EA. BOILER MODEL 32-380ECS 1 1 3 1 1 1 1 1 1 1 1 311035 311037 32-475ECS 1 1 4 1 1 1 1 1 1 1 1 311035 311037 SERIES 32 MASTER PARTS LIST FOR 32-380ECS & 32-475ECS DESCRIPTION SECTIONS BAS E SIDE PANEL ...

  • Crown Boiler 32-475ECS - page 13

    BASE SIDE CAR TON - See Installation Manual JACKET SIDE P ANEL CAR TON- See Installation Manual W A TER AND STEAM BOILER CAR TONS - As shown in Installation Manual except that Rating Plate is factory applied to RH Side Jacket Panel. BASE P AR TS - Base parts are identical to those shown in Installation Manual with the following exceptions: 1) 24 V ...

  • Crown Boiler 32-475ECS - page 14

    12 STEAM PROBE CONTROL SUB ASSY 3513210 1 LWCO, CG400 WITH "P" PROBE 400824 1 BLOCKED VENT SWITCH ASSY 960128 1 GLASS SET (20-104-10, 8" CTR TO CTR) 950080 1 L404F PRESSURE LIMIT 3503805 1 STRAIGHT BRASS PIGTAIL 95-060 1 1/2 X 4 BRASS NIPPLE 950004 1 1/2 BRASS TEE 951441 1 1/2 BRASS PLUG 95-091 1 PRESSURE GAUGE 95-070 1 1/2 X 1/4 BRA ...

  • Crown Boiler 32-475ECS - page 15

    ...

  • Crown Boiler 32-475ECS - page 16

    PN 980895 05/10 T el: (215) 535-8900 • Fax: (215) 535-9736 • www .crownboiler .com Manufacturer of Hydronic Heating Products P .O. Box 14818 3633 I. Street Philadelphia, P A 19134 ...

Manufacturer Crown Boiler Category Boiler

Documents that we receive from a manufacturer of a Crown Boiler 32-475ECS can be divided into several groups. They are, among others:
- Crown Boiler technical drawings
- 32-475ECS manuals
- Crown Boiler product data sheets
- information booklets
- or energy labels Crown Boiler 32-475ECS
All of them are important, but the most important information from the point of view of use of the device are in the user manual Crown Boiler 32-475ECS.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Crown Boiler 32-475ECS, service manual, brief instructions and user manuals Crown Boiler 32-475ECS. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Crown Boiler 32-475ECS.

A complete manual for the device Crown Boiler 32-475ECS, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Crown Boiler 32-475ECS by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Crown Boiler 32-475ECS.

A complete Crown Boiler manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Crown Boiler 32-475ECS - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Crown Boiler 32-475ECS, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Crown Boiler 32-475ECS, that we can find in the current document
3. Tips how to use the basic functions of the device Crown Boiler 32-475ECS - which should help us in our first steps of using Crown Boiler 32-475ECS
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Crown Boiler 32-475ECS
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Crown Boiler 32-475ECS in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Crown Boiler 32-475ECS?

Use the form below

If you did not solve your problem by using a manual Crown Boiler 32-475ECS, ask a question using the form below. If a user had a similar problem with Crown Boiler 32-475ECS it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)