  • Miller Electric RPC-IP - page 1

    RPC-IP    Multiprocess W elding Remote Pendant Control  April 1993 Ef f. w/Serial Number JJ487350 V isit our website at     ...

  • Miller Electric RPC-IP - page 2

    OM-533 Page 1 SECTION 1 – INTRODUCTION 5-3/4 in. (141 mm) 9-3/8 in. (238 mm) 5 in. (123 mm) ST -109 521-A Figure 1-1. Dimensions 1-1. GENERAL INFORMA TION AND SAFETY A. General Information presented in this manual and on various la - bels, tags, and plates provided on this unit pertains to equipment design, installation, operation, maintenance, a ...

  • Miller Electric RPC-IP - page 3

    OM-533 Page 2 SECTION 2 – INST ALLA TION W elding Power Source Remote Control Receptacle RPC-IP Receptacle ST -109 782-B Figure 2-1. Power Source/Remote Control Connections W ARNING: ELECTRIC SHOCK can kill. • Do not touch live electrical parts. • Shut down welding power source, and be sure it cannot be accidentally energized before making re ...

  • Miller Electric RPC-IP - page 4

    OM-533 Page 3 ST -1 13 509-A Mounting Screws (5) Front Panel Cover Dip Switch Circuit Board PC5 Both dip switches down for 1000 ampere model operation Both dip switches up for 650 ampere model operation Figure 2-2. Dip Switch Positions And Locations SECTION 3 – OPERA TOR CONTROLS 3-1. MODE SELECT OR SWITCH (Figure 3-1) The Mode Selector switch al ...

  • Miller Electric RPC-IP - page 5

    OM-533 Page 4 ST -109 521-A V oltmeter Ammeter V olts/Peak Control And Pilot Light Amps/Bkgd Control And Pilot Light Mode Selector Switch Ammeter Switch Arc Control Arc Control Pilot Light Contactor Switch Figure 3-1. Front Panel View 3-3. CONT ACTOR SWITCH (Figure 3-1) W ARNING: ELECTRIC SHOCK can kill. • Do not touch live electrical parts. • ...

  • Miller Electric RPC-IP - page 6

    OM-533 Page 5 3-6. VOL TS/PEAK CONTROL AND PILOT LIGHT (Figure 3-1) This control presets weld voltage for constant voltage applications and peak voltage for GMA W-P applica- tions. When the Mode Selector switch is in the CV position or one of the pulses per second positions, the VOL TS/ PEAK pilot light turns on. This control is disabled when the M ...

  • Miller Electric RPC-IP - page 7

    OM-533 Page 6 1 1. Preset VOL TS/PEAK control to desired peak volt- age setting (see Section 3-6). Pilot light should be on. 12. Make adjustments to wire feeder . 13. T urn on shielding gas supply . 14. Begin welding. 4-2. GAS MET AL ARC AND FLUX CORED ARC WELDING (GMA W AND FCA W) W ARNING: Read and follow safety informa - tion at beginning of ent ...

  • Miller Electric RPC-IP - page 8

    OM-533 Page 7 12. Make adjustments to wire feeder . 13. T urn on flux supply system. 14. Begin welding. 4-5. GAS TUNGSTEN ARC WELDING (GT A W) W ARNING: Read and follow safety informa - tion at beginning of entire Section 4 before proceeding. 1. Install and prepare welding power source according to its Owner ’s Manual. 2. Install Remote Control a ...

  • Miller Electric RPC-IP - page 9

    OM-533 Page 8 SECTION 5 – MAINTENANCE & TROUBLESHOOTING 5-1. MAINTENANCE Usage and shop conditions will determine the frequency and type of maintenance. Inspect equipment as follows: W ARNING: ELECTRIC SHOCK can kill. • Do not touch live electrical parts. • Shut down welding power source, and dis- connect remote control before inspecting, ...

  • Miller Electric RPC-IP - page 10

    OM-533 Page 9 SECTION 6 – ELECTRICAL DIAGRAMS Circuit Diagram No. SB-107 993-B Diagram 6-1. Circuit Diagram For Pendant Control Circuit Diagram No. SB-124 223 Diagram 6-2. Circuit Diagram For Circuit Board PC5 ...

  • Miller Electric RPC-IP - page 11

    OM-533 Page 10 Diagram 6-3. Wiring Diagram For Pendant Control Wiring Diagram No. SC-122 538-B ...

  • Miller Electric RPC-IP - page 12

    OM-533 Page 1 1 SECTION 7 – P ARTS LIST Description Part No. Dia. Mkgs. Item No. Figure 7-1. Main Assembly Quantity 1 108 056 CASE SECTION, front end 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 109 779 CASE 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Manufacturer Miller Electric Category Welder

Documents that we receive from a manufacturer of a Miller Electric RPC-IP can be divided into several groups. They are, among others:
- Miller Electric technical drawings
- RPC-IP manuals
- Miller Electric product data sheets
- information booklets
- or energy labels Miller Electric RPC-IP
All of them are important, but the most important information from the point of view of use of the device are in the user manual Miller Electric RPC-IP.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Miller Electric RPC-IP, service manual, brief instructions and user manuals Miller Electric RPC-IP. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Miller Electric RPC-IP.

A complete manual for the device Miller Electric RPC-IP, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Miller Electric RPC-IP by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Miller Electric RPC-IP.

A complete Miller Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Miller Electric RPC-IP - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Miller Electric RPC-IP, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Miller Electric RPC-IP, that we can find in the current document
3. Tips how to use the basic functions of the device Miller Electric RPC-IP - which should help us in our first steps of using Miller Electric RPC-IP
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Miller Electric RPC-IP
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Miller Electric RPC-IP in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Miller Electric RPC-IP?

Use the form below

If you did not solve your problem by using a manual Miller Electric RPC-IP, ask a question using the form below. If a user had a similar problem with Miller Electric RPC-IP it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)