Manual Drolet 45221

24 pages 0.81 mb
Download

Go to site of 24

Summary
  • Drolet 45221 - page 1

    45221 OWNER`S MANUAL Escape 1400-I Insert US ENVIRONMENTAL PROT ECTION AGENCY PHASE II CERTIFIE D W OO D INSERT Verified and tested follow ing ULC S628 and UL 1482 S tandards by : Intertek Testing Services Manufactured by : STOVE BUILDER INTERNA TIONAL INC. . 1700, Léon -Harm el, Québec (Québec) G1N 4R9 Tel : (418 ) 527- 3060 Fax : (418 ) 527- 4 ...

  • Drolet 45221 - page 2

    1 IN T R OD U C T IO N SBI INC., one of the most important wood stove and firep lace man ufacturers in Cana da, congratulates y ou on y our purchase and w ishes to help you get m aximum satisf action f rom your wood insert. In th e pages that follow, we will give you ad vice on wood h eating and contro lled combustion as well as tech nical specif i ...

  • Drolet 45221 - page 3

    2 TABLE OF CONTENTS IN TR OD U CT IO N ................................ ..................................................................................................... 1 Section 1.0 Pre- Installation Requirements ............................................................................................. 4 1.1 Masonry & Zer o Clearance R ...

  • Drolet 45221 - page 4

    3 Escape 1400-I Dimensions 13 29/64" 28 25/64" 26 29/32" 6.000" O 9 61/64" 20 31/32" 13 3/8" 6 31/64" 8 9/32" 8 9/64" 15 1/32" 20 31/32" Faceplate fully extended toward the back Faceplate fully extended toward the front ...

  • Drolet 45221 - page 5

    4 Section 1.0 Pre-Installation Requirements 1.1 Masonry & Zero Clearance Requirements The masonry fireplace must meet the minimum code require ments, or NFPA 211 or the equivale nt for a safe installation. Contact y our local Building I nspector for requirements in y our area. An inspection of the fireplace should include the following: 1. COND ...

  • Drolet 45221 - page 6

    5 1.2 Venting Requireme nts The flue is a critical component to a satisfactory installa tion. Your insert will attain its best performance if installed with a flue that generates its own draft. The minimum venting requirement will be the inst allation of a flue connector from the insert int o the first tile of the chimney (see Figure 2.3). If y ou ...

  • Drolet 45221 - page 7

    6 Section 2.0 Installation 2.1 Clearance s To Combustibles (Measured From Insert Body ) Escape 1400-I Sidewall (A) 13” (330 mm) 14” (356mm) Top mantel (B) 22” (559 mm) Side mantle (C) 10” (254 mm) Shelf (D) 29” (737 mm) Table 2.1 CLEA RANC ES Figure 2.1 Note: If side m antle protrud es more than 1.5” (38mm) in front of face of f ireplac ...

  • Drolet 45221 - page 8

    7 2.1.1 Hearth Require ments I f the non- combustible hearth is flush with the floor, then the hearth must be 16”/406mm (18”/450mm in Canada) in front of the fan housing (see Figure 2.1.2). If the non - combustible hearth is a minimum of 4” (102mm) above the floor, then the hearth can be 6” (152 mm) out fr om the fan housing with a 10” (2 ...

  • Drolet 45221 - page 9

    8 2.3 Safety Information NOTE: This applian ce is not recomm ended f or use in a h ome if an occupant has any respiratory or any other related p roblems. 1. I t is important to follow the installation and operation instructions. An im properly installed or operated insert could result in a safety hazard or fire, or damage to the unit, which would n ...

  • Drolet 45221 - page 10

    9 2.4 Install ation Instructions 1. I nspect the fireplace according to the safety information and fireplace requirements and have it cleaned and/or upg raded as necessary . 2. I f the installation of the unit renders the ex isting damper control inaccessible, it will be necessary to either secure the damper wide open or remove it entirely. An inac ...

  • Drolet 45221 - page 11

    10 2.5 A ir control plate, fac eplate and fan A ssembly Instructions 1. Place the face plate panels with the finished side down on a f lat, soft, non-abrasive surface . 2. Assemble the face plate trim, attaching the mitere d corners with the corne r brackets. (see Fig ure 2.4) 3. L ine up the holes of the side and top panels and se cure with the sc ...

  • Drolet 45221 - page 12

    11 2.6 Install ation of the adapter for fresh air kit I n order to avoid some combustion problems, it is highly recommended to install an adapter for fresh air kit. To do so, y ou need to have the accessory #AC01298. Usi ng plier s, re mov e the meta l rec tan gle (A ) loca ted on the side of the insert. Choose the side that is best for your instal ...

  • Drolet 45221 - page 13

    12 Section 3.0 Operation 3.1 Safety Information 1. This insert is designed for safe operation W HEN B URNING C ORDWOOD O NLY . Altering or mod if y ing the unit or the installation without proper authorization will void the certification, warranty , and safety listing, and may result in a safety hazard. 2. For safety reasons, never leave the unit u ...

  • Drolet 45221 - page 14

    13 air leakage into the unit, such as through deteriorated gaskets or cracked or broken glass. Do not operate the insert without a door gasket. Lea kage can result in overheating , or in very airtight homes, could possibly cause smoke spillage into the room. Smoke may contain carbon monoxide, which is poisonous, and in sufficient quantities is a he ...

  • Drolet 45221 - page 15

    14 An example of the energ y values of some c ommon wood fuels is given in Table 3.1 For recomme nded wood sizes, refer to the specifica tions. Common Heating Values of Cordwood Hardwoods Million Btu/Cord Softwoods Million Btu/Cord Birch 23.6 Douglas Fir 20.6 White Oak 28.3 Hemlock 17.1 Alder 17.6 Jack Pine 18.4 Table 3.1 3.2.1 Simple Wood Moisture ...

  • Drolet 45221 - page 16

    15 6. I deally the large kindling should be burned until a thick bed of red embers is obtained. At that point, add cordwood fuel and continue to opera te the dra ft control wide open until the fire is well established. Once the firebox is hot, the draft control can be par tia lly clo sed by movin g the knob to the left to adjust the intensity of th ...

  • Drolet 45221 - page 17

    16 3.5 Maintaining The Fire Your Drolet insert will work best if a thick bed of hot embers is maintained in the bottom of the firebox, and a mi nimum of two large pieces of seasoned fuel are added. Combustion efficiency is largely related to establishing a hot ember be d, and hot firebox tempera tures. The quicker the insert and fuel g et up to ope ...

  • Drolet 45221 - page 18

    17 Section 4.0 Maintenance 4.1 Care And Cleaning Clean the insert frequently so that soot, ash and creosote do not accumulate. Do not attempt to clean the insert, glass or door when the unit is hot. Special care must be taken with plated surfaces in order to maintain the finish at its original brilliance. Do not use an abrasive glass cleaner which ...

  • Drolet 45221 - page 19

    18 4.2 A sh Removal CA UTION: Ashes can start fires, eve n after several days of inactivity. Never dispose of ashes in a combustible con tainer. Rem ove ashes on ly when the inse rt and ashes are cold . Ashes should be removed from the insert frequently . When ashes are removed, they should be plac ed in a metal container with a tightly fitti ng li ...

  • Drolet 45221 - page 20

    19 4.4 Baffle Installa tion for Escape 1400 -I Figure 4.1 – Baffle installation & removal for Escape 14 00 -I The baffle assembly must be properly in plac e for correct burning operation. Have any damaged firebricks re placed. Check the firebricks annually for damag e and replace if they are broken or damaged. See Fig ure 3.3 for the firebric ...

  • Drolet 45221 - page 21

    20 4.5 Secondary A ir Tube Repla cement (see Fig ure 4.3) 1. Remove cotter pin at RH end of tube. 2. Slide tube to left and lower tube end be low RH plenum. 3. Slide tube to right to remove. 4. Reassemble in reverse order using a new cotter pin. The cotter pin is a hammerlock style and locks into place by hitting the head sharply with a hammer. 5. ...

  • Drolet 45221 - page 22

    21 4.6 Fan Maintenance & Care Clean the fan air inl et louvres and squirrel cage impeller regularly . The fan should be kept clean and dust free. L ife of the fan will be shortened if operated in a dust filled environment, or if the fan is overheated by restricting a ir supply . Stalling the rotor, or over firing the insert with the fan turne d ...

  • Drolet 45221 - page 23

    22 Section 5.0 Specifications 5.1 Esca pe 1400 -I Insert Model Fuel Ty pe Cordwood Test Standards UL C S628 (CSA B366.2) & UL 1482 residential. Recommended surfac e : 700 to 1600 sq. ft. Heating c apacity * – BTU/hr., EPA test wood: 39,000 BTU/h. Heating c apacity * – BTU/hr., seasoned cordwood : 60,000 BTU/h. Optimum efficiency : 75% *Why ...

  • Drolet 45221 - page 24

    23 DROLET LIMITED LIFETIME WA RRA NTY The warranty of the manu facturer extends o nly to the original co nsum er purchaser and is not transferable. T his warranty covers brand new prod ucts only, which have not been altered, modified nor repair ed since shipment from factory. P roof of purchas e (d ated bill of sale), model name and serial num ber ...

Manufacturer Drolet Category Indoor Fireplace

Documents that we receive from a manufacturer of a Drolet 45221 can be divided into several groups. They are, among others:
- Drolet technical drawings
- 45221 manuals
- Drolet product data sheets
- information booklets
- or energy labels Drolet 45221
All of them are important, but the most important information from the point of view of use of the device are in the user manual Drolet 45221.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Drolet 45221, service manual, brief instructions and user manuals Drolet 45221. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Drolet 45221.

Similar manuals

A complete manual for the device Drolet 45221, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Drolet 45221 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Drolet 45221.

A complete Drolet manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Drolet 45221 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Drolet 45221, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Drolet 45221, that we can find in the current document
3. Tips how to use the basic functions of the device Drolet 45221 - which should help us in our first steps of using Drolet 45221
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Drolet 45221
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Drolet 45221 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Drolet 45221?

Use the form below

If you did not solve your problem by using a manual Drolet 45221, ask a question using the form below. If a user had a similar problem with Drolet 45221 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)