Manual Mio STANDARD

12 pages 0.16 mb
Download

Go to site of 12

Summary
  • Mio STANDARD - page 1

    Aquachlor  Salt Water Chlorinator Owners Manual Model Standard and Self Clean C Series II Manufactured in Australia By Monarch Pool Systems www.monarch poolsystems.com ...

  • Mio STANDARD - page 2

    2 Aquachlor  Salt Chlorinator Thankyou for purchasing a Quality Aquachlor Pool and Spa Product. Please read all information in this Manual carefully before installing or operating your AQUACHLOR  SALT CHLORINATOR. INDEX Page 2 Packing List Page 3 Installation Instructions Page 4 Pre Start Up Procedure Page 4-5 Operation of Aquachlor  Syste ...

  • Mio STANDARD - page 3

    3 INSTALLATION INSTRUCTIONS FOR AQUACHLOR C and SC INSTALLING THE POWER SUPPLY : Select a convenient well-ventilated location within one metre of filter equipment and mount the Power Supply vertically onto a post or wall 1.5 metres above ground level. Australian Standards requires that the Power Supply shall not be located within 3 meters of the po ...

  • Mio STANDARD - page 4

    4 PRE - START UP PROCEDURE : Before operating your Aquachlor  Chlorinator please ensure the following items have been added to your pool: • SALT - Load salt into the pool at a minimum rate of 40kg per 10,000 litres (0.4%). Connect vacuum system and slowly vacuum until salt dispersal is complete. Place vacuum head into deepest end of pool and a ...

  • Mio STANDARD - page 5

    5 BAR METER WARNING LED REASON/ACTION Off Green 1. Start – up delay functioning. 2. System Control set below max. Cell is turned off. (Refer System Control page 7). Off Red 1. Gas detected. Check pump/pipes for damage. 2. Gas sensor not connected to cell 4 or 5 LEDs on Green System operating normally 1 to 5 LEDs on Red 1. Salt level too low. Add ...

  • Mio STANDARD - page 6

    6 If the Cell is OFF and you wish to check its operation, simply turn the System Control to MAX and the Cell will turn ON. Once checked, adjust the System Control back to the desired position and after a few minutes the Cell will turn OFF again. To turn the Cell OFF, simply turn the System Control to MIN. This will be convenient for backwashing. WA ...

  • Mio STANDARD - page 7

    7 Terminal Block the coloured wires from your pool light are connected. The Light Transformer is for use with 12volt pool lights, maximum power is 150Watt. Please Note: Only one light can be connected to each light transformer. If more than one light is required please refer to your Aquachlor  dealer. SAFETY NOTICE IMPORTANT Certain local electr ...

  • Mio STANDARD - page 8

    8 Aquachlor  C Standard Aquachlor  SC Self Clean C Standard Systems Model C Replacement Cell Model to order SC Self Clean Systems Model SC Replacement Cell Model to order 260 260 250 250 390 390 330 330 520 520 SC SYSTEMS Please Note that unless you have extreme water conditions the Cell should not become scaled and you should not have to cle ...

  • Mio STANDARD - page 9

    9 Stabiliser should be added at the rate of 500 grams for every 10,000 litres of water. To add, place the required amount in a stocking and tie a brick to it. Place the stocking in front of the return jet. It will dissolve in 2 – 3 days. Stabiliser should be maintained at a level of 30 – 50 ppm. Before adding more stabiliser, have your pool wat ...

  • Mio STANDARD - page 10

    10 The Aquachlor  unit has a built in warning system to minimise damage resulting from insufficient salt levels, however, the ultimate responsibility is on the owner to ensure adequate salt levels are maintained all year round. 4. RUNNING TIMES: If you run your chlorinator for 24 hours a day, or for long periods, the Cell life will be greatly re ...

  • Mio STANDARD - page 11

    11 Aquachlor Model C (Standard) Aquachlor Model SC (Self Clean) Productio n maximum grams/hou r (100%) Production * grams/hour (65% equivalent) Chlorine produce d over 8 hours grams (100%) Equivalent in dry granulated chlorine grams (65%) Equivalent in liquid chlorine litres (12%) 220 250 16.0 24.6 128 197 1.07 260 20.0 30.8 160 246 1.33 330 25.0 3 ...

  • Mio STANDARD - page 12

    12 IMPORTANT: ALWAYS INSIST ON GENUINE AQUACHLOR REPLACEMENT PARTS. If it is necessary to replace the Electrolytic Cell, beware of “look alikes”. Only the Genuine Aquachlor Cell is designed and warranted to operate with the Aquachlor Power Supply. SERIOUS DAMAGE MAY RESULT TO THE ELECTRONICS INSIDE THE UNIT IF COPY ELECTRODES ARE USED AND WILL ...

Manufacturer Mio Category Water Dispenser

Documents that we receive from a manufacturer of a Mio STANDARD can be divided into several groups. They are, among others:
- Mio technical drawings
- STANDARD manuals
- Mio product data sheets
- information booklets
- or energy labels Mio STANDARD
All of them are important, but the most important information from the point of view of use of the device are in the user manual Mio STANDARD.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Mio STANDARD, service manual, brief instructions and user manuals Mio STANDARD. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Mio STANDARD.

Similar manuals

A complete manual for the device Mio STANDARD, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Mio STANDARD by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Mio STANDARD.

A complete Mio manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Mio STANDARD - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Mio STANDARD, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Mio STANDARD, that we can find in the current document
3. Tips how to use the basic functions of the device Mio STANDARD - which should help us in our first steps of using Mio STANDARD
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Mio STANDARD
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Mio STANDARD in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Mio STANDARD?

Use the form below

If you did not solve your problem by using a manual Mio STANDARD, ask a question using the form below. If a user had a similar problem with Mio STANDARD it is likely that he will want to share the way to solve it.

Copy the text from the picture