    METROLOGIC INSTRUMENTS, INC. TECH 8 Laser Bar Code ™ Projection Scanner Installation and User’s Guide MLPN 2168 Printed in USA September 199 8 ...

  • Metrologic TECH 8 - page 2

    ii Locations : USA Corporate Headquarters Europe Metrologic Instruments, Inc. Metrologic Instruments GmbH Blackwood, NJ 08012 Munich, Germany Customer Service: 1-800-ID-METRO Tel: 49-89-89018-0 Tel: 609-228-8100 Fax: 49-89-89019-200 Fax: 609-228-6673 ASIA South America Metrologic Asia (PTE) Ltd. Metrologic Instruments Singapore 417818 CEP 04571-090 ...

  • Metrologic TECH 8 - page 3

    iii Table of Contents Unpacking List ............................................................ 1 Introduction .............................................................. 1 Labels ................................................................... 2 Applications and Protocols ................................................... 2 Maintenance .. ...

  • Metrologic TECH 8 - page 4

    1 Unpacking List The shipping carton, will contain the following: ! TECH 8 Laser Bar Code Projection Scanner ! Installation and User’s Guide ! ScanSelect™ Scanner Programming Guide ! Communication Cable (optional) or Communication Cable with Power Supply (optional) ! Stand (optional) If any item is missing or to order additional items, contact ...

  • Metrologic TECH 8 - page 5

    2 Labels One label is found inside the window of the scanner noting that this device is a CDRH Class IIa laser product and EN 60825-1 LASERKLASSE 1. Also, on the scanner is a label on the back of the unit. This label contains information such as the model number, the date of manufacture and the serial number. The following are samples of the labels ...

  • Metrologic TECH 8 - page 6

    3 Maintenance Smudges or dirt that appears on the scanner window can interfere with proper scanning. Therefore, the window will need occasional cleaning. 1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. 2. Gently wipe the scanner window. Configuration of the Scanner to the Host System The scanner has been configured at the time o ...

  • Metrologic TECH 8 - page 7

    4 Scanner Connections In order for the scanner to maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV ( S afety E xtra L ow V oltage) according to EN 60825-1. To avoid potential problems, do not power up the scanner until the communication cable is secured to the host. 1. Turn off ...

  • Metrologic TECH 8 - page 8

    5 Figure 1 Attaching the Scanner to the Stand and Work Surface The scanner can be positioned in a vertical orientation with the Metrologic stand (Part #45478). To attach the unit to the stand and work surface purchase the following: four 6-32 x ½" (maximum length) machine screws and two #10 panhead or #8 countersunk wood screws. 1. Lay the sc ...

  • Metrologic TECH 8 - page 9

    6 Figure 4 Scanning Bar Codes The depth of field for the scanner is 203mm to 457mm (8" to 18") from the scanner window. The symbol must be passed through the scan area in order for the scanner to recognize the bar code. (Refer to Figure 2) ...

  • Metrologic TECH 8 - page 10

    7 Appendix A TECH 8 Laser Bar Code Scanner Specifications ™ Application Industrial Scanner Light Source Visible Laser Diode 670 ± 5nm Laser Class CDRH: Class IIa; EN 60825: Class 1 Certifications CE, UL listed for US and Canada EMC FCC Class A, CISPR Class A Mechanical Dimensions 203mm x 216mm x 96mm (8"L x 8.5"W x 3.8"D) Weight 3 ...

  • Metrologic TECH 8 - page 11

    8 Operational Depth of Scan Field 203mm to 457mm (8" to 18") Scan Speed Model 870 1250 scan lines per second Model 875: 450 scan lines per second Scan Pattern Model 870: Omnidirectional (20 interlocking lines) Model 875: 6-line raster Indicators LED: green=on ready to scan; red=good read Beeper Operation Selection of 3 tones for “Good R ...

  • Metrologic TECH 8 - page 12

    9 Figure 4 Appendix B Version A1 Pin Assignments for the Mil spec Connector Each TECH 8 scanner has a 19-pin male Mil spec connector that is found on the side of the unit. To connect the scanner to the host device, use a communication cable with a female Mil spec connector. The communication cable may include a power transformer or it may be design ...

  • Metrologic TECH 8 - page 13

    10 Figure 5 Version A15 Pin Assignments for the Mil spec Connector Each TECH 8 scanner has a 19-pin male Mil spec connector that is found on the side of the unit. To connect the scanner to the host device, use a communication cable with a female Mil spec connector. The communication cable may include a power transformer or it may be designed to dra ...

  • Metrologic TECH 8 - page 14

    11 Appendix C Warranty and Disclaimer Limited Warranty Products manufactured by Metrologic have a 2-year limited warranty from date of manufacture. This warranty is limited to repair, replacement or refund at Metrologic’s discretion. Faulty equipment must be returned to the Metrologic facility in Blackwood, New Jersey or Puchheim, Germany. To do ...

  • Metrologic TECH 8 - page 15

    12 Disclaimer Metrologic Instruments, Inc. and the author or authors make no claims or warranties with respect to the contents or accuracy of this publication, or the product it describes, including any warranties of fitness or merchantability for a particular purpose. Any stated or expressed warranties are in lieu of all obligations or liability f ...

  • Metrologic TECH 8 - page 16

    13 Appendix D Notices Notice This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can rad ...

  • Metrologic TECH 8 - page 17

    14 Attention L'emploi de commandes, réglages ou procédés autres que ceux décrits ici peut entraîner de graves irradiations. Le client ne doit en aucun cas essayer d'entretenir lui-même le scanner ou le laser. Ne regardez jamais directement le rayon laser, même si vous croyez que le scanner est inactif. N'ouvrez jamais le scann ...

  • Metrologic TECH 8 - page 18

    15 Appendix E Patents “Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No. 4,360,798; 4,369,361; 4,387,297; 4,460,120; 4,496,831; 4,593,186; 4,607,156; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,059,7 ...

  • Metrologic TECH 8 - page 19

    16 Index A E AC outlet 4 Electrical 7 Application 7 Email ii Application and protocols 2 EN 60825-1 2, 4 Asia ii Environmental 8 ASIC 1 ESD 8 Attaching stand 5 EU 7 A1 pin assignments 9 Europe ii A15 pin assignments 10 Exit angle 8 B F B units 2 Faulty equipment 11 Bar codes 6 Fax ii Base 5 Functions 9, 10 Beeper operation 8 Bracket 5 G C Good read ...

  • Metrologic TECH 8 - page 20

    17 M Maintenance 3, 8 System interfaces 8 MECCA 1 Mechanical 7 T Mil spec connector 4, 7, 9, 10 Temperature 8 Model number 2 Top cover 7 Mounting options 7 Transformer 4, 7, 9, 10 N U NEMA-12 steel case 1, 7 UL/CSA 7 Notices 13, 14 Units 2 O ii OCIA 2, 9 Operating current 7 V Operating temperature 8 Ventilation 8 Operational 8 Version A1 9 Optional ...

Manufacturer Metrologic Category Scanner

Documents that we receive from a manufacturer of a Metrologic TECH 8 can be divided into several groups. They are, among others:
- Metrologic technical drawings
- TECH 8 manuals
- Metrologic product data sheets
- information booklets
- or energy labels Metrologic TECH 8
All of them are important, but the most important information from the point of view of use of the device are in the user manual Metrologic TECH 8.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Metrologic TECH 8, service manual, brief instructions and user manuals Metrologic TECH 8. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Metrologic TECH 8.

Similar manuals

A complete manual for the device Metrologic TECH 8, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Metrologic TECH 8 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Metrologic TECH 8.

A complete Metrologic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Metrologic TECH 8 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Metrologic TECH 8, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Metrologic TECH 8, that we can find in the current document
3. Tips how to use the basic functions of the device Metrologic TECH 8 - which should help us in our first steps of using Metrologic TECH 8
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Metrologic TECH 8
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Metrologic TECH 8 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Metrologic TECH 8?

Use the form below

If you did not solve your problem by using a manual Metrologic TECH 8, ask a question using the form below. If a user had a similar problem with Metrologic TECH 8 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)