  • Bradford-White Corp E32-80R - page 1

    (To be performed ONLY by qualified service providers) Save this manual for future reference Manual 239-47157-00B Commercial Electric Energy Saver: E32-50S E32-80R E32-120R ...

  • Bradford-White Corp E32-80R - page 2

    Page Service Procedure Introduction ………………………………………………………………………. 2 - - - Tools……………………………………………………………………………… 2 - - - General Information ……………………………………………………………… 3 - - - Sequence of Operat ...

  • Bradford-White Corp E32-80R - page 3

    GENERAL INFORMATION Ungrounded Ungrounded Groundin g BLACK RED GREEN 240 120 120 120 ABC Neutral RED BLACK RED 120 120 208 208 208 277 ABC Neutral RED BLACK RED 277 277 480 480 480 120 ABC Neutral RED BLACK RED 120 120 240 240 240 Amps = Watts (for single phase units) Exam ple 4500W/240V = 18.75A Volts Amps = Watts (for balanced 3 phase units) Exam ...

  • Bradford-White Corp E32-80R - page 4

    GENERAL INFORMATION Full Load Amperes-(Phase 1/Phase 3) Page 4 Input Kw 208V 28.8/16.6 240V 277V 380V 415V 480 V 6 9 12 13.5 15 18 43.2/25 57.6/33.3 64.9/37.5 72.1/37.5 86.5/50 25/14.4 37.5/21.6 50/28.9 56.2/32.5 62.5/36.1 75/43.4 21.6 32.4 43.3 48.7 54.1 64 10 14 19 21 23 28 8.3 12.5 16.7 18.8 20.9 25 12.5/7.2 18.7/10.8 25/14.4 28.1/16.2 31.2/18 3 ...

  • Bradford-White Corp E32-80R - page 5

    SEQUENCE OF OPERATION E32 series medium duty, field convertible commercia l electr ic water heaters are designed to operate using single pha se or three phase service connectio ns. On e size fits all Inte rnal fusing is factory installed for all units. When field conversions are required, no fuse change is necessary . Three surface mounted thermost ...

  • Bradford-White Corp E32-80R - page 6

    Page 6 FIELD CONVERSION FOR: KW, Voltage and Phase All E32 series medium duty commercial water heaters are fact ory wired to the maximum electrical duty for which they have been designed. Therefore, internal electrical co mponents satisfy the ma ximum voltage and maximum ele ctrical current conditions. These instructions do not allow for a modifica ...

  • Bradford-White Corp E32-80R - page 7

    Electrical Phase Conversion Electrical phase conversion will require a change fro m si ngle-phase to three-phase or an opposite conversion change from three-phase to single-pha se. Each of thes e conversions will be explai ned sepa rately as follows: Three-Phase to Single-Phase 1. Disconnect blue and yellow wires from terminal L-3 of the termin al ...

  • Bradford-White Corp E32-80R - page 8

    The heaters rating plate will need to be modified because t he conversion altered the electr ical characteristics of the heater. Refer to the illustration below that displays a typical co mmercial electric rating plate that is to be altered. This rating plate is placed on every Commercial Electric water heater produced by Bradford Wh ite Corporatio ...

  • Bradford-White Corp E32-80R - page 9

    TROUBLESHOOTING Most common cause for improper electric water heater operation can be linked to h eating element failure. When troubleshooting an ele ctric water heater with the inci dence of “No Hot Water” or “Insufficient Amoun t of Hot Water” It is always a good idea to check the heati ng elements first fo llowing the procedu re on page ...

  • Bradford-White Corp E32-80R - page 10

    SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION No Hot Water 1. No Power to heater. 2. Blown water heater fuses. 3. Loose wire connections. 4. Inoperative heating elements. 5. Inoperative thermostat . 6. Open ECO. 1. Inoperative heating element. 2. Thermostat(s) set to lo w. 3. Inoperative thermostat (s). 4. Loose wire connection. 5. Sediment or lime buil ...

  • Bradford-White Corp E32-80R - page 11

    SERVICE PROCEDURE E32-I Heating Element Testing Step 1. TURN OFF POWER TO WATER HEATER. Step 2. Remove thermostat/elem ent access cover(s) from front of water heate r. Remove insulation and plastic cover from thermosta t. Step 3. Disconnect wires from heatin g eleme nt. Step 4. Set multi-meter to “ohms” setting. Step 5. Touch probe s of multi-m ...

  • Bradford-White Corp E32-80R - page 12

    SERVICE PROCEDURE E32-II Line Voltage Testing WARNING High voltage exposure. Use caution when making voltage checks to avoid personal injury. Line Voltage Testing Illustration 3 7. For 3 phase service check across L1 & L2 and across L1 and L3 (see illustrations 4 & 5) A) Rated voltage IS pres ent, power to the water heater is okay. B) Rated ...

  • Bradford-White Corp E32-80R - page 13

    SERVICE PROCEDURE E32-III Fuse Testing Fuse Testing 1. Turn “OFF” power to water heater. 2. Open control b ox located at the top of the heater to allow access to fuse block. 3. Disconnect wire leads from fuse block. NOTE: It may be nece ssary to label wires for proper re-connection when finished. 4. Set multi-meter to the “Ohms” setting. 5. ...

  • Bradford-White Corp E32-80R - page 14

    SERVICE PROCEDURE E32-IV Thermostat Testing WARNING High voltage exposure. Use caution to avoid personal injury duri ng this procedure. Illustration 8 Water In Tank Is Cold With Power ON. 1. This procedure assumes line voltage, ECO and elements are in working order. 2. Turn power “O N” to water heater. 3. Set multi-meter to “Volts AC”. 4. C ...

  • Bradford-White Corp E32-80R - page 15

    SERVICE PROCED URE E32-V Thermostat Removal and Replacement Front View Thermostat Mounting Thermostat Removal 1. Turn power “OFF” To water heater. 2. Remove access cover(s) and ins ulation. 3. Remove plastic thermostat protector from thermostat(s). 4. Disconnect wires from thermostat terminals. It may be necessary to label wires for proper re-c ...

  • Bradford-White Corp E32-80R - page 16

    SERVICE PROCEDURE E32-VI Heating Element Removal and Replacement Heating Element Removal 1. Turn power “OFF” To water heater. 2. Turn off cold water supply to heater. Connect hose to drain spigot of water heater and route to an open drain. Open a nearby hot water faucet to vent heater for draining. Open drain spigot of water heater and allow he ...

  • Bradford-White Corp E32-80R - page 17

    Page 17 Step 1. Turn power “OFF” to water heater. Step 2. Turn off cold water supply to h eater. Connect hose to drain spigot of water heater and route to an open drain. Open a nearby hot water faucet to vent hea ter for dr aining. Open drain spigot of water heater and allow heater to drain to a p oint below the inlet connection nipple. Step 3. ...

  • Bradford-White Corp E32-80R - page 18

    Page 18 Generic Parts List 1. Hot Water Outlet Anode 2. T&P Relief Valve 3. Cold Water Inlet Dip Tube 4. Control Box 5. Ground Lug 6. Fuse 7. Fuse Block 8. Terminal Block 9. Brass Drain Valve 10. Thermostat Mounting Bracket 11. Element Gasket 12. Heating Element 13. Thermostat Surface Mount 14. Thermostat Protector 15. Thermostat/Element Access ...

  • Bradford-White Corp E32-80R - page 19

    ...

  • Bradford-White Corp E32-80R - page 20

    Email parts@bradfordwhite.com techserv@bradfordwhite.com www .bradfordwhite.com ...

Manufacturer Bradford-White Corp Category Water Heater

Documents that we receive from a manufacturer of a Bradford-White Corp E32-80R can be divided into several groups. They are, among others:
- Bradford-White Corp technical drawings
- E32-80R manuals
- Bradford-White Corp product data sheets
- information booklets
- or energy labels Bradford-White Corp E32-80R
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bradford-White Corp E32-80R.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bradford-White Corp E32-80R, service manual, brief instructions and user manuals Bradford-White Corp E32-80R. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bradford-White Corp E32-80R.

A complete manual for the device Bradford-White Corp E32-80R, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bradford-White Corp E32-80R by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bradford-White Corp E32-80R.

A complete Bradford-White Corp manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bradford-White Corp E32-80R - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bradford-White Corp E32-80R, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bradford-White Corp E32-80R, that we can find in the current document
3. Tips how to use the basic functions of the device Bradford-White Corp E32-80R - which should help us in our first steps of using Bradford-White Corp E32-80R
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bradford-White Corp E32-80R
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bradford-White Corp E32-80R in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bradford-White Corp E32-80R?

Use the form below

If you did not solve your problem by using a manual Bradford-White Corp E32-80R, ask a question using the form below. If a user had a similar problem with Bradford-White Corp E32-80R it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)