    306–993 Rev . D Supersedes Rev . B and PCN C First choice when quality counts.  INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Hydra-Clean ) Pressure W ashers 42 bar , 4.2 MPa (600 psi) Maximum Working Pressure For Mounting on Open 55 Gallon Supply Drum (Can be wall m ...

  • Graco Inc. 306-993 - page 2

      T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T roubleshooting 10 . . . . . . . . . . . ...

  • Graco Inc. 306-993 - page 3

      W ARNING INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause an extremely serious injury , including the need for amputation. Splashing fluid in the eyes or on the skin can also cause a serious injury .  Fluid injected into the skin might look like just a cut ...

  • Graco Inc. 306-993 - page 4

    4 306-993 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re - sult in a fire or explosion and serious injury .  Ground the equipment and the object being sprayed. Refer to Grounding on page 5.  If there is any static sparking or you feel an electric shock whil ...

  • Graco Inc. 306-993 - page 5

    5 306-993 Setup Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below . Also read the section FIRE OR EXPLOSION HAZARD on page 4. Although water generally provides a natural electrical ground, the following equipment must be grounded if the cleaning chemical are volatile. 1. When cleaning in en ...

  • Graco Inc. 306-993 - page 6

      Setup Connect Hoses and Mount Pump Connect hoses and pump as follows: NOTE: This pump is supplied with a bracket (D) which holds it to the side of a drum. If you want to install the pump on a wall, do not install the hanging bracket. Use Graco W all Mounting Bracket 206–778 or equivalent for wall setup. 1. Screw the hose ...

  • Graco Inc. 306-993 - page 7

    7 306-993 Setup  D U B F M J R P KEY A Barbed Hose Stud B Suction Hose C Pump Intake housing D Bracket E Screw , Lockwasher , and Nut F Pump Runaway V alve G Air Line Lubricator H Pump Air Bleed V alve (required, for pump) J Air Regulator and Gauge K Air Line Filter L Air Line Drain V alve M Bleed–type Air V alve (for accessorie ...

  • Graco Inc. 306-993 - page 8

    8 306-993 Operation General Information The following instructions are for operation of the Monark 5:1 Ratio Hydra–Clean Pressure W ashers Model 205–985 and Model 207–860. Callouts in parentheses refer to Figure 2. Pressure Relief Procedure W ARNING INJECTION HAZARD Fluid under high pressure can be in - jected through the skin and cause serio ...

  • Graco Inc. 306-993 - page 9

      Operation W ARNING T o avoid serious injury , including fluid injection and splashing in the eyes or on the skin, never point the gun at yourself or anyone else. Before Using See Fig. 2. Prepare cleaning solution as instructed, observing all safety precautions. Pre-mix powered cleaners in a separate bucket of hot water bef ...

  • Graco Inc. 306-993 - page 10

    10 306-993 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Before servicing this equipment always make sure to relieve the pressure . Note: Check all possible problems and solutions before disassembling. Problem Cause Solution Exc ...

  • Graco Inc. 306-993 - page 11

    11 306-993 Service General W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. See Parts illustration for referenced items. Shut of f the air supply to the pump and relieve the pressure . Check the air line lubricator often and keep it filled with oil ...

  • Graco Inc. 306-993 - page 12

    12 306-993 Parts 0676 8 17 (MODEL 205–985) 11 4 13 2 18 15 21 19 14 16 20 3 5 12 6 Model 205–985 Monark Hydra-Clean and Model 207–860 Monark Hydra-Clean 1 7 8 8 9 10 (MODEL 207–860) 22 23 ...

  • Graco Inc. 306-993 - page 13

    13 306-993 Parts Model 207–860 Monark Hydra-Clean Ref No. Part No. Description Qty . 1 214–847 AIR LINE LUBRICA TOR 1 2* 206–300 FIL TER, fluid intake 1 3 224–343 5:1 Ratio Monark Pump See manual 308–1 16 for parts 1 4 102–022 BUSHING, hex; 1/2 npt; 1/4 npt thd size 1 5 102–023 SCREW , hex cap; 1/4–20 thd size; 3/4” (19mm) long 1 ...

  • Graco Inc. 306-993 - page 14

    14 306-993 Accessories Stainless Steel Spray Tips AIR SUPPL Y T O PUMP TIP NO. ORIFICE SIZE SPRA Y ANGLE 70 PSI (4.8 bar , 0.48 MPa) 100 psi (7 bar , 0.7 MPa) NO . SIZE ANGLE GPM CFM WP GPM CFM WP 164–435 .043 40 160–964 .043 25 164–434 .052 25 164–436 .052 40 1.6 17 610 1.8 24 840 164–438 .052 65 160–963 .062 25 2.3 23 560 2.6 32 750 K ...

  • Graco Inc. 306-993 - page 15

    15 306-993 Dimensions 24.5” (622 mm) 1 1.75” (298 mm)  T echnical Data Air pressure range 40 to 120 psi (2.8 to 8.4 bar , .28 to .84 MPa) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air volume requirements 8.2 cfm (0.23 m 3 /min.) at 100 psi (7 bar , 0.7 MPa), . . . . . . . . . . . ...

  • Graco Inc. 306-993 - page 16

    16 306-993 Graco Standard W arranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warrant ...

Manufacturer Graco Inc. Category Pressure Washer

Documents that we receive from a manufacturer of a Graco Inc. 306-993 can be divided into several groups. They are, among others:
- Graco Inc. technical drawings
- 306-993 manuals
- Graco Inc. product data sheets
- information booklets
- or energy labels Graco Inc. 306-993
All of them are important, but the most important information from the point of view of use of the device are in the user manual Graco Inc. 306-993.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Graco Inc. 306-993, service manual, brief instructions and user manuals Graco Inc. 306-993. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Graco Inc. 306-993.

Similar manuals

A complete manual for the device Graco Inc. 306-993, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Graco Inc. 306-993 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Graco Inc. 306-993.

A complete Graco Inc. manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Graco Inc. 306-993 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Graco Inc. 306-993, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Graco Inc. 306-993, that we can find in the current document
3. Tips how to use the basic functions of the device Graco Inc. 306-993 - which should help us in our first steps of using Graco Inc. 306-993
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Graco Inc. 306-993
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Graco Inc. 306-993 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Graco Inc. 306-993?

Use the form below

If you did not solve your problem by using a manual Graco Inc. 306-993, ask a question using the form below. If a user had a similar problem with Graco Inc. 306-993 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)