Manual Teledyne HFM-60

30 pages 1.04 mb
Download

Go to site of 30

Summary
  • Teledyne HFM-60 - page 1

    page 1 INSTRUCTION MODEL HFM-60 MODEL HFM-60 MODEL HFM-60 MODEL HFM-60 MODEL HFM-60 FLOWMETER FLOWMETER FLOWMETER FLOWMETER FLOWMETER INSTRUMENTS TELEDYNE HASTINGS INSTRUCTION MANUAL ...

  • Teledyne HFM-60 - page 2

    page 2 Manual Print History Manual Print History Manual Print History Manual Print History Manual Print History The pr int histor y shown below lists the printing dates of all revisions and addenda created for this manual. The revision level letter increases alphabetically as the manual undergoes subsequent updates . Addenda, which are released bet ...

  • Teledyne HFM-60 - page 3

    page 3 T T T T T able of Contents able of Contents able of Contents able of Contents able of Contents 1.0 1.0 1.0 1.0 1.0 GENERAL INFORMA GENERAL INFORMA GENERAL INFORMA GENERAL INFORMA GENERAL INFORMA TION TION TION TION TION ............................................................. ............................................................. ...

  • Teledyne HFM-60 - page 4

    page 4 ...

  • Teledyne HFM-60 - page 5

    page 5 General Information SECTION 1 The Hastings Mass Flowmeter, HFM-60 is designed to accurately measure mass flow up to 70 slpm with an accuracy of better than 3%. Hastings mass flow instruments do not require any periodic maintenance under normal operating conditions with clean gases. No damage will occur from the use of moderate overpressures ...

  • Teledyne HFM-60 - page 6

    page 6 1.2 Specifications Accuracy ......................................................................................................................... <±3% F .S. Repeatability ................................................................................................. ±0.2% of F .S.(typical) ±0.4% of F .S. (max.) Maximum pressure . ...

  • Teledyne HFM-60 - page 7

    page 7 1.3 Optional 4-20 mA Current Output An option to the standard 0-5 VDC output is the 4-20 mA current output that is propor tional to flow . The 4 - 20 mA signal is produced from the 0 - 5 VDC output of the flowmeter. The cur rent loop output is useful for remote applications where pickup noise could substantially affect the stability of the v ...

  • Teledyne HFM-60 - page 8

    page 8 ...

  • Teledyne HFM-60 - page 9

    page 9 Installation SECTION 2 This section contains the necessar y steps to assist in getting a new flowmeter in operation as quickly and easily as possible. Please read the following thoroughly before attempting to install the instru- ment. W W W W W ARNING ARNING ARNING ARNING ARNING The customer should determine if their process gas is compatibl ...

  • Teledyne HFM-60 - page 10

    page 10 There is a threaded hole in the bottom of the transducer that can be used to secure it to a mount- ing bracket, if desired. Other holes for special mounting can be added to the end cap as desired. The standard inlet and outlet fittings for the HFM-60 are 1/4" NPT to 1/4" Swagelok (optional VCR and VCO fittings are av ailable from ...

  • Teledyne HFM-60 - page 11

    page 11 2.6.4 Range Changes: The range of the flowmeter can be changed in the field if recalibra tion facilities are a vailable. The flowmeter ma y require a different shunt which can be purchased from the factor y . A listing of available shunts (order codes) and the corresponding air equivalent flow ranges are as follows: Order Code Shunt Range O ...

  • Teledyne HFM-60 - page 12

    page 12 ...

  • Teledyne HFM-60 - page 13

    page 13 Theory of Operation SECTION 3 This section contains an overall functional description of the HFM-60. Detailed schematics and parts lists can be found at the end of the manual in Section 5.0. In this section and other sections throughout this manual, it is assumed that the customer is using the wall transformer power supply supplied b y Hast ...

  • Teledyne HFM-60 - page 14

    page 14 3.3 Base The 6061 aluminum alloy base has a 1" square cross-section and is 3.375" long (with end cap). The internal flow channel is 0.812" diameter with in and out 304L stainless steel fittings 1/4" NPT to 1/4" Swagelok fittings. 3. 4 Shunt The flo w rate of interest determines the size of the shunt required. As pre ...

  • Teledyne HFM-60 - page 15

    page 15 Aluminum epoxy figure 3.3 (a) 10 sccm - 200 sccm (typical configuration) figure 3.3 (b) annular flow passages 500 sccm - 70 slm (typical configuration) flow flow ...

  • Teledyne HFM-60 - page 16

    page 16 3.5 Electronic Circuitr y The HFM-60 employs a thermal flow sensor (capillar y tube descr ibed in section 3.2) to measure the flow which is proportional to the total flow through the instr ument. The sensor develops a differential voltage output signal proportional to flow which is approximately 1 mV full scale magnitude. A differential amp ...

  • Teledyne HFM-60 - page 17

    page 17 4.1 Authorized Maintenance With proper care in installation and use, the flowmeter will require little or no maintenance. If maintenance does become necessar y , most of the instr ument can be cleaned or repaired in the field. Some procedures may require recalibration. Do not attempt these procedures unless facilities are av ailable. Entr y ...

  • Teledyne HFM-60 - page 18

    page 18 4.3 Adjustments Calibration Procedure (See figure 4.1) 1. Connect pow er to pins 1 and 2 as specified in Section 2.5. Allow the instrument to warm up for 30 minutes with 10% flow . 2. Completely shut off the flow and wait for 2 minutes. For the standard 0-5VDC output, adjust the zero potentiometer located on the lower outlet side of the flo ...

  • Teledyne HFM-60 - page 19

    page 19 4.4 End Cap Removal The end cap on the inlet side must be remov ed to gain access to the filter and shunt assembly . First remove power and shut off the supply of gas to the instrument. Disconnect the Swagelok fittings on the inlet and outlet sides of the transducer and remove it from the system plumbing. Remov e the two Allen head screws h ...

  • Teledyne HFM-60 - page 20

    page 20 4.5 Printed Circuit Board Replacement In the event that any of the PC boards fail, they are easily removed from the instrument and replaced with a spare. This ease in disassembly and replacement substantially reduces instrument downtime. 1 . Replacement of the 4-20 mA option PC board: Unplug the power cable from the trans ducer. If a digita ...

  • Teledyne HFM-60 - page 21

    page 21 W arranty and Repair SECTION 5 5.1 W ar ranty Repair P olic y Hastings Instruments warrants this product for a period of one year from the date of shipment to be free from defects in material and workmanship . This warranty does not apply to defects or failures resulting from unauthorized modification, misuse or mishandling of the product. ...

  • Teledyne HFM-60 - page 22

    page 22 ...

  • Teledyne HFM-60 - page 23

    page 23 Diagrams and Drawings SECTION 6 ...

  • Teledyne HFM-60 - page 24

    page 24 ...

  • Teledyne HFM-60 - page 25

    page 25 ...

  • Teledyne HFM-60 - page 26

    page 26 ...

  • Teledyne HFM-60 - page 27

    page 27 ...

  • Teledyne HFM-60 - page 28

    page 28 ...

  • Teledyne HFM-60 - page 29

    page 29 ...

  • Teledyne HFM-60 - page 30

    page 30 ...

Manufacturer Teledyne Category Automobile Parts

Documents that we receive from a manufacturer of a Teledyne HFM-60 can be divided into several groups. They are, among others:
- Teledyne technical drawings
- HFM-60 manuals
- Teledyne product data sheets
- information booklets
- or energy labels Teledyne HFM-60
All of them are important, but the most important information from the point of view of use of the device are in the user manual Teledyne HFM-60.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Teledyne HFM-60, service manual, brief instructions and user manuals Teledyne HFM-60. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Teledyne HFM-60.

Similar manuals

A complete manual for the device Teledyne HFM-60, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Teledyne HFM-60 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Teledyne HFM-60.

A complete Teledyne manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Teledyne HFM-60 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Teledyne HFM-60, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Teledyne HFM-60, that we can find in the current document
3. Tips how to use the basic functions of the device Teledyne HFM-60 - which should help us in our first steps of using Teledyne HFM-60
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Teledyne HFM-60
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Teledyne HFM-60 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Teledyne HFM-60?

Use the form below

If you did not solve your problem by using a manual Teledyne HFM-60, ask a question using the form below. If a user had a similar problem with Teledyne HFM-60 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)