Manual SMC Networks EX9-AC002-3

19 pages 2.35 mb
Download

Go to site of 19

Summary
  • SMC Networks EX9-AC002-3 - page 1

    Reduced wiring system EX250 - SEN1 Instruction Manual EtherNet/IP™ Compatible SI Unit URL http:// www.smcworld.com Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. EtherNet/IP™ is a trademark used under licence by ODVA. The descriptions of products shown in this document may be used b ...

  • SMC Networks EX9-AC002-3 - page 2

    Contents Thank you for purchasing the SMC reduced wiring system EX250 series. Please read this instruction manual carefully and understand the contents before use so that you can operate this unit safely and correctly. Please keep this manual handy for future reference. OPERA T OR This instruction manual has been written for those who ha ve kno wle ...

  • SMC Networks EX9-AC002-3 - page 3

    2 3 SAFETY The body of unit and this manual contain the essential information for the protection of users and others from possible injury and property damage and to ensure correct handling. Please check that you fully understand the definitions of the following messages ( symbols ) before going on to read the body of this manual, and always follow ...

  • SMC Networks EX9-AC002-3 - page 4

    4 5 Pr oduct Summar y Power supply for Output Block (for high wattage load) 24VDC Connecting to bus at upper level (EtherNet/IP) Power supply for output/input and control 24VDC Solenoid valve Output Block (for high wattage load) Power Block Output Block (for low wattage load) SI Unit applicable to EtherNet/IP Input Block End Plate This system reali ...

  • SMC Networks EX9-AC002-3 - page 5

    6 7 SI Unit Model Indication Method Ti e-rod (2 pcs.) Accessory Note1 : For wiring method, refer to subsection "Wiring" (page 12) in this manual. Note2 : For display and setting method, refer to subsection "Display/Setting" (page 15) in this manual. Dimensions ( unit : mm ) BUS BUS PWR PWR SOL SOL NS NS PWR PWR SETTINGS SETTINGS ...

  • SMC Networks EX9-AC002-3 - page 6

    8 9 Mounting/Installation (continued ) Layout of the Input Block Position the Input Block on the left side of the SI Unit. Layout of the EX9 series Output Block / Power Block Position the Output Block / Power Block on the right side of the SI Unit and between the SI Unit and solenoid valve or End Plate R (on the Output Block side). 1) Output Block ...

  • SMC Networks EX9-AC002-3 - page 7

    10 11 Specifications Sensor input area 1 0 I/O mapping Offset (word) Input data MSB LSB MSB LSB 15 8 70 0 1 Input area mapping 15 14 L : Fixed to Low Item Status Condition SP Solenoid power supply status 0 No supply voltage 1 Supply voltage OK DI Status of sensor power supply 0 Short circuit 1 Normal Diagnostics (Status input area) 2 LL LL LL LL L ...

  • SMC Networks EX9-AC002-3 - page 8

    12 13 Wiring 43 2 1 1 34 2 M12 1 2 +Rx 3 - Tx 4 - Rx 1 2 3 4 5 6 7 8 Shield RJ45 6.7 47.3 45 2000 Model No. : EX9-AC020EN-PSRJ +Tx Wiring diagram Cable core wire external color Terminal No. Pin assignment of plug connector Pin assignment of plug connector White/Orange Orange White/Green Green 8 7 6 5 4 3 2 1 Connect the Power Supply Cable to the po ...

  • SMC Networks EX9-AC002-3 - page 9

    14 15 Wiring ( continued ) 24VDC 24VDC Brown : 24VDC (for solenoid valv es/output) White : 0V (for solenoid valv es/output) Grey : Ear th Blue : 24VDC (for input and control) Black : 0V (for input and control) Cable P ar t No . : EX500-AP -S 24VDC Brown : 24VDC (for solenoid valv es/output) White : 0V (for solenoid valv es/output) Grey : Ear th Blu ...

  • SMC Networks EX9-AC002-3 - page 10

    16 17 12345678 ON 1 0 IP address 192.168.0.X 1 0 1 0 1 0 1 2 0 0 1 1 1 1 3 0 0 0 0 1 1 4 0 0 0 0 1 1 Remote control * 1 X 3 2 1 14 DHCP mode * 2 SW1 Communication setting CLEAR/HOLD Manual set up of IP address * 3 SW1 5 0 1 1 1 1 1 6 - - 0 1 - - 7 - - - - 0 1 SW1 Item Communication setting Communication speed Communication method Contents AUTO : Th ...

  • SMC Networks EX9-AC002-3 - page 11

    18 19 Input Bloc k Model Indication Method EX250 IE Block type 1 2 3 Input points : 2, M12 connector (2pcs.) Input points : 4, M12 connector (2pcs.) Input points : 4, M8 connector (4pcs.) Input Block Model indication method Pa rt Names No. Part names Application 1 Input equipment connector Connects the input equipment such as sensor, etc. Note1 2 O ...

  • SMC Networks EX9-AC002-3 - page 12

    20 21 Wiring EX250-IE3 EX250-IE1/2 EX250-IE1 (M12 connector, 5 pin, Socket) EX250-IE2 (M12 connector, 5 pin, Socket) *1) Input No.1 is connected to the pin No.2 of the input connector "0", 2 input signals can be directly input from the input connector "0". *2) NC : Not connected EX250-IE3 (M8 connector, 3 pin, Socket) 1 1 2 2 3 ...

  • SMC Networks EX9-AC002-3 - page 13

    22 23 Displa y/Setting EX250-IE1 EX250-IE2/IE3 0 0 1 1 EX250 EX250 0 0 1 1 2 2 3 3 EX250 EX250 Display Description PWR Lights up Power supply for sensor is ON. Off Power supply for sensor is OFF. 0, 1, 2, 3 Lights up Sensor signal input corresponding to the number is ON. (Logic "1") Off Sensor signal input corresponding to the number is O ...

  • SMC Networks EX9-AC002-3 - page 14

    24 25 Pa rt Names T ie-rod (2 pcs.) Accessory T ie-rod (2 pcs.) Accessory W aterproof cap (for socket)(1 pc.) Dimensions ( unit : mm ) 59.8 72.6 21 Output Block 59.8 80.3 21 PWR PWR Po wer Bloc k Mounting/Installation Refer to subsection "Mounting/Installation" (page 7) in this manual. Specifications Model No. EX9-OET1 EX9-OEP1 Power supp ...

  • SMC Networks EX9-AC002-3 - page 15

    26 27 Wiring ( continued ) Output connector pin lay out EX9-OET1, EX9-OEP1 (M12 connector, 5 pin, Socket) Output No.1 *1 Output No.0 NC *2 1 NC *2 3 GND 5 NC *2 4 4 1 1 4 4 1 1 2 2 3 3 2 2 3 3 5 5 5 5 Output connector "0" Output connector "1" Output wiring Cable wiring Pin alignment and connection drawing of the Output Cable Plu ...

  • SMC Networks EX9-AC002-3 - page 16

    28 29 Wiring ( continued ) M12 connector, 5 pin, Reverse key 1 Power supply for output (24VDC) 2 Power supply for output (0VDC) 5 Ground ( 3 Power supply for sensor (24VDC)) * ( 4 Power supply for sensor (0V)) * 4 4 1 1 4 4 1 1 2 2 3 3 2 2 3 3 5 5 5 5 Power supply connector (Socket) Power input connector (Plug) * It is used when power is supplied t ...

  • SMC Networks EX9-AC002-3 - page 17

    30 31 Wiring ( continued ) Displa y Output Block PWR PWR Po wer Bloc k The Power Supply Cable (for Power Supply Connector of Power Block) is a bypass cable which can be used when the Power Block is positioned next to the SI Unit. Option EX500 - AP 050 - S How to order Cable length (L) Connector specification 010 1 [m] 050 5 [m] S Straight EX9 - AC ...

  • SMC Networks EX9-AC002-3 - page 18

    32 33 Option ( continued ) Waterproof Cap Mounted on the unused ports of the Input Block, Output Block and Power Block. The proper use of this Waterproof Cap can achieve IP67 Enclosure. (The Waterproof Caps are delivered together with the Power Block as accessories.) 9 EX500 - AW How to order Connector specification ES M8 connector ( for socket ) / ...

  • SMC Networks EX9-AC002-3 - page 19

    34 Tr oubleshooting ( continued ) MS LED status Normal status : Green light ON Fatal failure : Red light ON 1 The effect of noise is possible. Check the installation conditions. If the trouble cannot be solved even if the installation conditions are checked, contact our sales branch. NS LED status Offline/Power is OFF : Light OFF Online/Communicati ...

Manufacturer SMC Networks Category Switch

Documents that we receive from a manufacturer of a SMC Networks EX9-AC002-3 can be divided into several groups. They are, among others:
- SMC Networks technical drawings
- EX9-AC002-3 manuals
- SMC Networks product data sheets
- information booklets
- or energy labels SMC Networks EX9-AC002-3
All of them are important, but the most important information from the point of view of use of the device are in the user manual SMC Networks EX9-AC002-3.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals SMC Networks EX9-AC002-3, service manual, brief instructions and user manuals SMC Networks EX9-AC002-3. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product SMC Networks EX9-AC002-3.

A complete manual for the device SMC Networks EX9-AC002-3, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use SMC Networks EX9-AC002-3 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of SMC Networks EX9-AC002-3.

A complete SMC Networks manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual SMC Networks EX9-AC002-3 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the SMC Networks EX9-AC002-3, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the SMC Networks EX9-AC002-3, that we can find in the current document
3. Tips how to use the basic functions of the device SMC Networks EX9-AC002-3 - which should help us in our first steps of using SMC Networks EX9-AC002-3
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with SMC Networks EX9-AC002-3
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of SMC Networks EX9-AC002-3 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning SMC Networks EX9-AC002-3?

Use the form below

If you did not solve your problem by using a manual SMC Networks EX9-AC002-3, ask a question using the form below. If a user had a similar problem with SMC Networks EX9-AC002-3 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)