Инструкция обслуживания Vermont Casting 1640

32 страниц 0.41 mb
Скачать

Перейти на страницу of 32

Summary
  • Vermont Casting 1640 - page 1

    Homeowner ’ s Installation and Operating Manual For use in the United States and Canada SAFETY NO TICE: IF THIS APPLIANCE IS NO T PR OPERL Y INST ALLED, OPERA TED AND MAINT AINED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLO W THE INST ALLA TION INSTRUCTIONS. FAILURE T O FOLLO W INSTR UCTIONS MA Y RESUL T IN PROPER TY D AMA GE, B ...

  • Vermont Casting 1640 - page 2

    2 Intrepid 1640 Woodburning Stove 30000830 Introduction Thank you for choosing a Vermont Castings Intrepid to meet your heating needs. We're confident you will find the Intrepid to be an effective wood-burning heater incorporating modern, non-catalytic combustion technology with the classic aesthetic appeal of its Vermont Castings lineage. The ...

  • Vermont Casting 1640 - page 3

    3 Intrepid 1640 Woodburning Stove 30000830 Specifications Intrepid, Model 1640 Maximum Heat Output ........... 8,200 - 19,500 Btu’s/hr . 3 Maximum Heat Output ......................... 22,00 Btu’s/hr . 1 Area Heated .................... Up to 1000 sq. ft.(92 sq. m) 2 Fuel Size / T ype .............................. 16” (410 mm) logs EP A Emis ...

  • Vermont Casting 1640 - page 4

    4 Intrepid 1640 Woodburning Stove 30000830 SAFETY NOTICE: IF YOUR STOVE IS NOT PROP- ERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. FOR SAFETY, FOLLOW ALL INSTALLATION, OPERATION AND MAINTENANCE DIRECTIONS. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND IN µ . Before you begin an installation, review your plans to be ce ...

  • Vermont Casting 1640 - page 5

    5 Intrepid 1640 Woodburning Stove 30000830 Masonry Chimneys, cont'd. • Unused openings in an existing masonry chimney must be sealed with masonry to the thickness of the chimney wall, and the chimney liner should be repaired. Openings sealed with pie plates or wallpa- per are a hazard and should be sealed with mortar or refractory cement. In ...

  • Vermont Casting 1640 - page 6

    6 Intrepid 1640 Woodburning Stove 30000830 Double-wall Chimney Connectors The Intrepid is approved for installation in the U.S. and Canada with double-wall chimney connectors that have been tested and listed for use with solid-fuel burning appliances by a recognized testing laboratory . Follow the instructions for assembling and installing double-w ...

  • Vermont Casting 1640 - page 7

    7 Intrepid 1640 Woodburning Stove 30000830 Connection Abo ve the Fireplace In this installation, the chimney connector enters the fireplace flue though a thimble located above the fireplace. The liner of the fireplace chimney should extend at least to the point at which the chimney connector enters the chimney . Follow all the guidelines for instal ...

  • Vermont Casting 1640 - page 8

    8 Intrepid 1640 Woodburning Stove 30000830 Fig. 13 CSA approved Wall Pass-through. 24 ga.Sheet Steel Support 24 ga. Sheet Steel Support (one side only) Min. 18" (460mm) Chimney clearance to sheet steel supports and combustibles 2" (51mm) Min. Chimney Flue Chimney Connector Masonry Chimney constructed to CAN/ CSA-B365 Min. 18" (460mm) ...

  • Vermont Casting 1640 - page 9

    9 Intrepid 1640 Woodburning Stove 30000830 In Canada, the floor protector required under the stove must extend 18” (457mm) to the front (‘E’, Fig. 14), and 8” (203mm) from the sides and rear . (‘D’ ,Fig. 14) To meet Canadian requirements, a floor protector must be at least 43" (1092mm) wide and 48" (1219mm) deep. Floor protect ...

  • Vermont Casting 1640 - page 10

    10 Intrepid 1640 Woodburning Stove 30000830 Reducing a stove clearance may require installation of a listed heat shield on the chimney connector as well. Clearances may be reduced only by means approved by the regulatory authority , or in accordance with the clearances listed in this manual. When determining clearance, always measure from the top p ...

  • Vermont Casting 1640 - page 11

    11 Intrepid 1640 Woodburning Stove 30000830 Fig. 17 Parallel installation, vertical chimney connector , two wall shields. A. 36" (914mm) B. 30" (762mm) C. 1" (25mm) D. 35" (889mm) E. 44" (1 1 18mm) F. 40" (1016mm) IN T R E PI D II C C C C D F A B E D ST508a Fig. 18 Parallel installation with rear wall pass-through, two ...

  • Vermont Casting 1640 - page 12

    12 Intrepid 1640 Woodburning Stove 30000830 Fireplace Clearances and Mantel Trim Shields A fireplace installation requires special clearance between the side of the stove and the right and left walls, between the side of the stove and the decorative side trim on the fireplace face, and between the top of the stove and the mantel. Noncombustible shi ...

  • Vermont Casting 1640 - page 13

    13 Intrepid 1640 Woodburning Stove 30000830 Alcove Installations Because of their restricted air flow and heat retention characteristics, specific construction requirements and special clearances apply to installations into alcoves. No stove or chimney connector heat shields are used in alcove installations. ALCOVE INSTALLATION OF THE INTREPID II I ...

  • Vermont Casting 1640 - page 14

    14 Intrepid 1640 Woodburning Stove 30000830 Stove in Corner Stove Installed Parallel to Wall Unprotected Surfaces 1. Shielding for a top exit stove must include the stove rear heat shield insert to protect the area behind the flue collar. 2. Chimney connector heat shields, in an installation that goes through a combustible ceiling, must extend to 1 ...

  • Vermont Casting 1640 - page 15

    15 Intrepid 1640 Woodburning Stove 30000830 D E F F C A B J K L L I I G H P Q M N C N/A N/A Top Exit No Chimney Connector Shields Rear Exit Top Exit with Chimney Connector Shields or Double-wall Chimney Connector Stove Installed Parallel to Wall Stove in Corner Unprotected Surfaces Protected Surfaces Stove Installed Parallel to Wall Stove in Corner ...

  • Vermont Casting 1640 - page 16

    16 Intrepid 1640 Woodburning Stove 30000830 Y ou will need the following tools to assemble the Intrepid: • 9/16" open end wrench • safety glasses & gloves • flat head screwdriver • power drill w/ 1/8" (3mm) bit Caution. The Intrepid is very heavy. Do not attempt to handle the stove without assistance. Unpack the Stove 1. Remov ...

  • Vermont Casting 1640 - page 17

    17 Intrepid 1640 Woodburning Stove 30000830 Attach the Chimney Connector 1. Insert the crimped end of the first section of chimney connector into the flue collar . 2. Using the holes in the collar as guides, drill 1/8" (3mm) holes through the connector pipe. 3. Use the three #10 x 1/2" sheet metal screws pro- vided to secure the chimney c ...

  • Vermont Casting 1640 - page 18

    18 Intrepid 1640 Woodburning Stove 30000830 Operation You will enjoy the best results when burning wood that has been adequately air-dried. Avoid burning “green” wood that has not been properly seasoned. The wood should be no longer than 16" (410 mm) in length, however, you will find that shorter wood lengths ease refueling and promote the ...

  • Vermont Casting 1640 - page 19

    19 Intrepid 1640 Woodburning Stove 30000830 A more effective option for delivering ample combustion air to the stove is to duct air directly from outdoors to the stove. In fact, in some areas, provisions for outside combustion air are required in all new construction. The optional Intrepid Outside Air Adaptor is available from your dealer. When you ...

  • Vermont Casting 1640 - page 20

    20 Intrepid 1640 Woodburning Stove 30000830 • During the break-in fires, don't let the stove get hotter than 500 ° F. (260 ° C) as measured on an optional stove-top thermometer . Adjust the air control lever as necessary to control the fire. • Some odor from the stove’s hot metal, the paint, and the cement is normal for the first few f ...

  • Vermont Casting 1640 - page 21

    21 Intrepid 1640 Woodburning Stove 30000830 Smoke Detectors The use of smoke detectors throughout the home is strongly advised, if not required by building codes or insurance regulations. It is a good idea to install a smoke detector in the living areas and each bedroom. Y ou may not, however , wish to install a detector in the immediate vicinity o ...

  • Vermont Casting 1640 - page 22

    22 Intrepid 1640 Woodburning Stove 30000830 Maintenance 4. Install the Glass. Lay the glass on the inner gasket with the coated side down (toward the outside of the door). T ighten the screws snugly , but loose enough to allow for a little movement of the glass when the stove is in operation. Overtightening can crack the glass immediately or cause ...

  • Vermont Casting 1640 - page 23

    23 Intrepid 1640 Woodburning Stove 30000830 4. Remove the gasket from the channel, place it on a wood cutting surface, and cut it at the marked spot with a utility knife. T wist the ends slightly to discour- age the gasket from unraveling. 5. Lay an unbroken 1/8" (3 mm) bead of gasket cement in the newly-cleaned channel. 6. Starting at one end ...

  • Vermont Casting 1640 - page 24

    24 Intrepid 1640 Woodburning Stove 30000830 Annual Maintenance Perform a thorough cleaning, inspection and repair each Spring, at the end of the heating season. • Thoroughly clean the chimney and chimney connec- tor . • Inspect the chimney for damage and deterioration. Replace weak sections of prefabricated chimney . Have a mason make repairs t ...

  • Vermont Casting 1640 - page 25

    25 Intrepid 1640 Woodburning Stove 30000830 Y our stove is only one part of a system that includes the chimney , the operator , the fuel and the home. The other parts of the system will affect how well the stove works. When there is a good match between all the parts, the stove works well. W ood stove operation depends on natural (unforced) draft. ...

  • Vermont Casting 1640 - page 26

    26 Intrepid 1640 Woodburning Stove 30000830 There should be no more than eight feet of single-wall stove pipe between the stove and a chimney . Longer runs can cool the smoke enough to cause draft and creosote problems. Use double-wall stove pipe for longer runs. Single V enting Y our stove requires a dedicated flue. Do not connect the stove to a f ...

  • Vermont Casting 1640 - page 27

    27 Intrepid 1640 Woodburning Stove 30000830 Negative Pressure Good draft also depends on a sufficient supply of air to the stove. The chimney cannot pull more air than is available. Sluggish draft can be caused by a house that is tight enough to prevent the ready flow of air to the stove, or by competition between the stove and other appliances tha ...

  • Vermont Casting 1640 - page 28

    28 Intrepid 1640 Woodburning Stove 30000830 1 2 1 2 3 2 2 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 23 24 48 46 45 44 43 42 41 40 39 38 37 61 62 63 64 65 66 67 68 69 70 59 58 34 35 36 32 31 30 29 28 27 26 25 49 50 51 52 53 54 56 57 7 13 22 26 28 31 31 32 33 33 34 34 35 35 37 38 47 47 51 52 53 54 55 60 60 60 60 65 65 65 65 65 65 65 65 65 65 5 ...

  • Vermont Casting 1640 - page 29

    29 Intrepid 1640 Woodburning Stove 30000830 Intrepid NC W oodburning Sto ve Model 1640 (continued) Item Description Part Number Item Description Part Number 33. Firebrick, Bottom - Left & Right (2) 30000971 34. Brick Bracket (3) 30000986 35. 1/4-20 x 1/4” Phillips Flt Hd Screw Blk (3) 1200897 36. Front See Chart Pg. 29 37. 1/4-20x1” Flat Hd ...

  • Vermont Casting 1640 - page 30

    30 Intrepid 1640 Woodburning Stove 30000830 ...

  • Vermont Casting 1640 - page 31

    31 Intrepid 1640 Woodburning Stove 30000830 W arranty Limited 3 Y ear W arranty CFM Specialty Home Products warrants that this woodburning stove will be free of defects in material and workmanship for a period of three years from the date you receive it, except that the catalyst, thermostat assembly, handles, glass door panels, cement, and gasketin ...

  • Vermont Casting 1640 - page 32

    © CFM Specialty Home Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www.vermontcastings.com CFM Specialty Home Products ...

Производитель Vermont Casting Категория Stove

Документы, которые мы получаем от производителя устройства Vermont Casting 1640 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Vermont Casting
- инструкции обслуживания 1640
- паспорта изделия Vermont Casting
- информационные брошюры
- энергетические этикетки Vermont Casting 1640
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Vermont Casting 1640.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Vermont Casting 1640, инструкции обслуживания, короткие инструкции или инструкции пользователя Vermont Casting 1640. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Vermont Casting 1640.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Vermont Casting 1640, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Vermont Casting 1640 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Vermont Casting 1640.

Полная инструкция обслуживания Vermont Casting, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Vermont Casting 1640 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Vermont Casting 1640, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Vermont Casting 1640, которое найдем в данном документе
3. Советы по использованию основных функций устройства Vermont Casting 1640 - которые должны облегчить нам первые шаги во время использования Vermont Casting 1640
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Vermont Casting 1640
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Vermont Casting 1640 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Vermont Casting 1640?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Vermont Casting 1640, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Vermont Casting 1640 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)