    RWB 6104 BAFG R02 Page 1 Beckett Beckett AF/AFG Oil Burner Manual T ype ‘M’ Air T ube Combination (AFG Models only) T ype ‘L1’ Head T ype ‘V1’ Head Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner: Please read and carefully follow all instructions provided in this manual regarding your responsi- bi ...

  • Beckett AFG - page 2

    Page 2 RWB 6104 BAFG R02 T able of Contents Hazard De fi nitions and Owner ’ s Information ........................................................................................ 3 Information T o Be Used Only By Quali fi ed Service T echnicians General Information ............................................................................... ...

  • Beckett AFG - page 3

    RWB 6104 BAFG R02 Page 3 T o the Owner: Thank you for purchasing a Beckett burner for use with your heating appliance. Please pay at- tention to the Safety W arnings contained within this instruction manual. Keep this manual for your records and provide it to your quali fi ed service agency for use in professionally setting up and maintaining your ...

  • Beckett AFG - page 4

    Page 4 RWB 6104 BAFG R02 T able 1 – Burner Speci fi cations Capacity ( Note 1 ) ‘F’ Head (AF & AFG) Firing rate range: .............. 0.40 – 3.00 GPH Input: ....................... 56,000 – 420,000 Btu ‘L1’ Head (AFG Only) Firing rate range: .................. 0.40 - 1.10 GPH Input: ..................... 56,000 – 154,000 Btu/h ...

  • Beckett AFG - page 5

    RWB 6104 BAFG R02 Page 5 SK9475 Notice Special Requirements For recommended installation practice in Canada, refer to the latest version of CSA Standard B139 & B140. Concealed damage — If you discover damage to the burner or controls during unpacking, notify the carrier at once and fi le the appropriate claim. When contacting Beckett for ser ...

  • Beckett AFG - page 6

    Page 6 RWB 6104 BAFG R02 T able 4. AFG Reduced Firing Rates (with LFRB) Burner head type Low Firing Rate Baf fl e installed F0 up to 0.65 gph F3 or L1 up to 0.85 gph F4 or F6 up to 0.90 gph V1 up to 1.00 gph Prepar e the Bur ner Low Firing Rate Baf fl e The AFG Low Firing Rate Baf fl e (LFRB) reduces the air fl ow and pressure. The LFRB is some ...

  • Beckett AFG - page 7

    RWB 6104 BAFG R02 Page 7 Attach air tube (if not already installed) If using a fl ange and gasket, slide them onto the air tube. Then attach the air tube to the burner chassis using the four sheet metal screws provided. Refer to Figure 3 for details. Install burner nozzle (if not already in- stalled) Remove the plastic plug protecting the nozzle a ...

  • Beckett AFG - page 8

    Page 8 RWB 6104 BAFG R02 Check/Adjust ‘Z’ Dimension - ‘F’ heads 1. The important ‘Z’ dimension is the distance from the face of the nozzle to the fl at face of the head (or heat shield, if applicable). This dis- tance for F heads is 1- ⅛ ” (1- ⅜ ” if the air tube has a heat shield). The “Z” dimension is factory set for burn ...

  • Beckett AFG - page 9

    RWB 6104 BAFG R02 Page 9 Check/Adjust ‘Z’ Dimension - L1 & L2 Heads Check/Adjust ‘Z’ Dimension - V1 Heads V1 Adjusting Plate Setting AFG with V1 Head Burner Firing Rates 0 0.75-1.00 1 1.00-1.50 2 1.50-1.75 3 1.75-2.00 4 2.00-2.25 5 2.25-2.50 6 2.50-2.75 T able for initial adjusting plate settings for V1 Head L1/L2 heads (see T able 7 an ...

  • Beckett AFG - page 10

    Page 10 RWB 6104 BAFG R02 The burner may be equipped with a single-stage fuel unit for these installations. Connect the fuel supply to the burner with a single supply line if you want a one-pipe system (making sure the bypass plug is NOT installed in the fuel unit.) Manual bleed- ing of the fuel unit is required on initial start-up. If connecting a ...

  • Beckett AFG - page 11

    RWB 6104 BAFG R02 Page 1 1 Never use T e fl on tape on fuel oil fi ttings. T ape fragments can lodge in fuel line components and fuel unit, damaging the equipment and pre- venting proper operation. Use oil-resistant pipe sealant compounds. y y y Damage to the pump could cause impaired burn- er operation, oil leakage and appliance soot-up. Do Not ...

  • Beckett AFG - page 12

    Page 12 RWB 6104 BAFG R02 7. RECYCLE. If the fl ame is lost while the burner is fi ring, the control shuts down the burner , enters a 60 second recycle delay , and then repeats the above ignition sequence. If fl ame is lost three times in a row , the control locks out to prevent cycling with repetitious fl ame loss due to poor combustion. 8. BU ...

  • Beckett AFG - page 13

    RWB 6104 BAFG R02 Page 13 Star t up bur ner/set combustion For R7184 primary controls, see T echnician’s Quick Reference Guide, part number 61351 for special pump priming sequence. Prepare for combustion tests by drilling a ¼” sam- pling hole in the fl ue pipe between the appliance and the barometric draft regulator . Initial air adjustment ? ...

  • Beckett AFG - page 14

    Page 14 RWB 6104 BAFG R02 P erfor m re gular maintenance Check all wiring for secure connections or insula- tion breaks. Check the pump pressure and cutoff function. Check primary control safety lockout timing. Check ignition system for proper operation. Inspect the vent system and chimney for soot ac- cumulation or other restriction. Clean the app ...

  • Beckett AFG - page 15

    RWB 6104 BAFG R02 Page 15 For best performance specify genuine Beckett replacement parts Professional Maintenance SK9462 # Part No. Description 1 Burner Housing Assembly 2 Specify Air Band - Specify # of slots 4198 Screw , 10-24 x 1/2” 4150 Nut, 10-24 Square 3 Specify Air Shutter - Specify # of slots 4292 Screws, 10-24 x 5/16” 4 3493 Escutcheon ...

  • Beckett AFG - page 16

    Page 16 RWB 6104 BAFG R02 Limited WARRANTY For Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its Beckett burners from Beckett for resale or for incorporation into a product for resale (“Customers”) that its equipment is free from defects in material and workmanship u ...

Производитель Beckett Категория Burner

Документы, которые мы получаем от производителя устройства Beckett AFG мы можем разделить на несколько групп. Это в частности:
- технические чертежи Beckett
- инструкции обслуживания AFG
- паспорта изделия Beckett
- информационные брошюры
- энергетические этикетки Beckett AFG
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Beckett AFG.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Beckett AFG, инструкции обслуживания, короткие инструкции или инструкции пользователя Beckett AFG. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Beckett AFG.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Beckett AFG, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Beckett AFG пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Beckett AFG.

Полная инструкция обслуживания Beckett, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Beckett AFG - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Beckett AFG, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Beckett AFG, которое найдем в данном документе
3. Советы по использованию основных функций устройства Beckett AFG - которые должны облегчить нам первые шаги во время использования Beckett AFG
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Beckett AFG
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Beckett AFG в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Beckett AFG?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Beckett AFG, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Beckett AFG со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)