Инструкция обслуживания Pelco C3407M-D

24 страниц 3.13 mb
Скачать

Перейти на страницу of 24

Summary
  • Pelco C3407M-D - page 1

    INST ALLA TION ICS150-CW Series Camclosure ® Integrated Camera System Wide Dynamic Range (WDR) C3407M-D (1/07) ...

  • Pelco C3407M-D - page 2

    ...

  • Pelco C3407M-D - page 3

    C3407M-D (1/07) 3 Contents Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Models . . . . . . . ...

  • Pelco C3407M-D - page 4

    4 C3407M-D (1/07) Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE Thi ...

  • Pelco C3407M-D - page 5

    C3407M-D (1/07) 5 Description The ICS150-CW Series Camclosure ® integrated camera system combines an environmental cover, back box, camera, lens, and lower dome into a small, high-security system that is quick and easy to install. The system is perfect for a variety of indoor and outdoor applications and its versatile design allows for multiple mo ...

  • Pelco C3407M-D - page 6

    6 C3407M-D (1/07) Figure 1. Package Components BACK BOX (1) CAMERA MODULE (1) TRIM RING, DOME LINER, AND CLEAR BUBBLE (1) TRIM RING AND SMOKED BUBBLE (1) < OR > 1/8-INCH HOLLOW SCREWDRIVER BIT (1) ADAPTER PLA TE (1) SHOWN ACTUAL SIZE SHIPPING BOX 8-32 X 1.25-INCH PHILLIPS FLA T HEAD SCREWS (4) 8-32 X 0.75-INCH PHILLIPS FLA T HEAD SCREWS (2) 8 ...

  • Pelco C3407M-D - page 7

    C3407M-D (1/07) 7 Cover and Back Box Installation The ICS150-CW Series Camclosure integrated camera system mounts only into a wall or ceiling. UNSHIELDED T WISTED PAIR (UTP) V IDEO The ICS150-CW Series offers support for unshielded twisted pair (UTP). The UTP video output signal is 1 Vp-p differential into a 100-ohm load. The unit uses active UTP . ...

  • Pelco C3407M-D - page 8

    8 C3407M-D (1/07) SUSPENDED CEILING NOTE: Y ou should install the camera module into the back box before installing the back box into the surface. When installing the back box into the surface, rotate the camera module to access the mounting holes. Refer to Camera Module on page 10 for more information. 1. Pull video and power wires to the ceiling ...

  • Pelco C3407M-D - page 9

    C3407M-D (1/07) 9 4S DEEP ELECTRICAL BOX NOTE: Y ou should install the camera module into the back box before installing the back box into the surface. When installing the back box into the surface, rotate the camera module to access the mounting holes. Refer to Camera Module on page 10 for more information. 1. Attach the supplied adapter plate to ...

  • Pelco C3407M-D - page 10

    10 C3407M-D (1/07) Camera Module The ICS150-CW Series Camclosure camera module includes the camera, camera bracket, and heater board. T o perform most camera adjustments, you must remove the module from the back box. Use the following instructions to remove and reinstall the camera module. MODULE REMOVAL T o remove the camera module from the back b ...

  • Pelco C3407M-D - page 11

    C3407M-D (1/07) 11 2. Unplug the camera (10-pin), heater board (four-pin), and service (three-pin) connectors from the back box (refer to Figure 6). Figure 6. Back Box Connectors CAMERA CONNECTOR HEA TER BOARD CONNECTOR SERVICE CONNECTOR ...

  • Pelco C3407M-D - page 12

    12 C3407M-D (1/07) CAMERA ORIENTATION At the factory , the camera module is confi gured for ceiling mounting. For wall mounting, you must change the camera orientation or the video image will be upside down. T o change the camera orientation (refer to Figure 7): 1. Remove the camera module from the back box if necessary . 2. Remove the tilt adjust ...

  • Pelco C3407M-D - page 13

    C3407M-D (1/07) 13 Camera Adjustments T o perform the following camera adjustments, make sure to plug in the camera and service connectors. Y ou may have to remove the camera module from the back box. Connect a monitor . Then turn on power to the camera and monitor. T o use the service connector, refer to Service Connector on page 18. T o adjust th ...

  • Pelco C3407M-D - page 14

    14 C3407M-D (1/07) SWITCH SETTINGS Locate the DIP switch (refer to Figure 9). Then set the switches for your installation. Figure 9. DIP Switch SW1: Video Format Set to ON for NTSC. Set to OFF for PAL. The default is ON. SW2: Line Sync Set to ON to use AC line lock. Set to OFF for internal line sync. The default is ON. SW3: Interlaced Scanning/Prog ...

  • Pelco C3407M-D - page 15

    C3407M-D (1/07) 15 Extended dynamic range: Use for extremely high dynamic installations, for example, doorways, entrances, and exits. This profi le offers the maximum wide dynamic range. Fluorescent: Use for any installation with fl ickering lighting of any kind. NOTE: If you select the Fluorescent profi le, you should enable AC line lock for be ...

  • Pelco C3407M-D - page 16

    16 C3407M-D (1/07) Camera Positioning Manually rotate and tilt the camera module to position the camera. Then tighten the tilt screws (axis  in Figure 11). NOTE: Do not over-rotate the module. Excessively turning the module in one direction could result in damage to the wiring. Figure 11. Positioning the Camera     T ilt 80° (20°-1 ...

  • Pelco C3407M-D - page 17

    C3407M-D (1/07) 17 Install Dome and T rim Ring 1. Adjust the dome liner if installed (refer to Figure 12): a. Align the screw holes in the trim ring with those in the back box to identify the proper dome liner position. b. Loosen the three Phillips screws located in the trim ring. c. Insert the blade of a standard screwdriver in one of the adjustme ...

  • Pelco C3407M-D - page 18

    18 C3407M-D (1/07) Service Connector The ICS150-CW Series Camclosure integrated camera system includes a service connector that outputs camera video. Use it at the installation site to set up the fi eld of view and focus the camera. Figure 13. Service Connector Pelco offers two optional items that plug directly into the service connector . Before ...

  • Pelco C3407M-D - page 19

    C3407M-D (1/07) 19 T o assemble a longer service cable for the Camclosure integrated camera system, purchase the following from a local electronics supply store: 1 2.5 mm monaural headphone plug 1 CPM 88 miniature coaxial connector 1 RG174/U coaxial cable T o assemble the cable: 1. Attach the CPM 88 miniature coaxial connector to one end of the cab ...

  • Pelco C3407M-D - page 20

    20 C3407M-D (1/07) Specifications CAMERA Imaging Device 1/3-inch imager Dynamic Range 102 dB typical/120 dB maximum Picture Elements Sensor resolution: 742 (H) x 552 (V) Signal System NTSC or PAL Scanning System 2:1 interlace/progressive Synchronization Internal/AC line lock Horizontal Resolution More than 504 TV lines Iris Control Auto Electronic ...

  • Pelco C3407M-D - page 21

    C3407M-D (1/07) 21 BACKBOX Electrical Input Voltage** 12 VDC or 24 VAC (±10%), autosensing Power Consumption 10 watts or less Video Connector Composite: BNC UTP: T wisted pair General Pan/T ilt Adjustment Manual Pan 360° T ilt 80° (20° to 100° range) Rotation 360° Construction Aluminum with steel camera mounting bracket and polycarbonate dome ...

  • Pelco C3407M-D - page 22

    22 C3407M-D (1/07) ...

  • Pelco C3407M-D - page 23

    PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repa ir or replace, without charge, any merc ha ndise proved defective in material or wo rkmanship for a period of one year after the date of shipment. Exception s to this warrant y are as noted bel ow: • Five years on FR/F T/FS Series fiber optic pr oducts and TW300 0 Series unshielded ...

  • Pelco C3407M-D - page 24

    Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO 9001 Australia | Canada | Finland | France | Italy | Russia | Singapore | Spain | Sweden The Netherlands | United Arab Emirates | United Kingdom | United St ...

Производитель Pelco Категория Home Security System

Документы, которые мы получаем от производителя устройства Pelco C3407M-D мы можем разделить на несколько групп. Это в частности:
- технические чертежи Pelco
- инструкции обслуживания C3407M-D
- паспорта изделия Pelco
- информационные брошюры
- энергетические этикетки Pelco C3407M-D
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Pelco C3407M-D.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Pelco C3407M-D, инструкции обслуживания, короткие инструкции или инструкции пользователя Pelco C3407M-D. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Pelco C3407M-D.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Pelco C3407M-D, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Pelco C3407M-D пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Pelco C3407M-D.

Полная инструкция обслуживания Pelco, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Pelco C3407M-D - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Pelco C3407M-D, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Pelco C3407M-D, которое найдем в данном документе
3. Советы по использованию основных функций устройства Pelco C3407M-D - которые должны облегчить нам первые шаги во время использования Pelco C3407M-D
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Pelco C3407M-D
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Pelco C3407M-D в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Pelco C3407M-D?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Pelco C3407M-D, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Pelco C3407M-D со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)