Инструкция обслуживания State Water Heaters CCVIT PR6 50

20 страниц 0.3 mb
Скачать

Перейти на страницу of 20

Summary
  • State Water Heaters CCVIT PR6 50 - page 1

    1 PRINTED IN U.S.A. 0305 P ART NO. 185172-000 KEEP THIS MANUAL IN THE POCKET ON THE HEATER FOR FUTURE REFERENCE WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED. Power V ented Gas Models PR6 40 XCVIT PR6 40 CCVIT PR6 50 XCVIT PR6 50 CCVIT with Hot Surface Ignition Thank you for buying this energy efficient water heater from S tate W ater Heat ...

  • State Water Heaters CCVIT PR6 50 - page 2

    2 GET TO KNOW YOUR W A TER HEA TER ( A ) VENT PIPE-EXHAUST (B) ANODE (C) HOT WA TER OUTLET (D) OUTLET (1 15 V AC) (E) FLUE BAFFLE (F) GAS SUPPL Y (G) MAIN MANUAL GAS SHUT OFF V AL VE (H) GROUND JOINT UNION (J) DIR T LEG (K) OUTER DOOR (L) UNION (M) INLET WA TER SHUT OFF V AL VE (N) COLD W A TER INLET REPLACEMENT P ARTS AND DELIMING PRODUCTS Replace ...

  • State Water Heaters CCVIT PR6 50 - page 3

    3 then call your gas supplier or service agent. Keep area clear until a service call has been made. At times you may not be able to smell an LP gas leak. One cause is odor fade, which is a loss of the chemical odorant that gives LP gas its distinctive smell. Another cause can be your physical condition, such as having a cold or a diminishing sense ...

  • State Water Heaters CCVIT PR6 50 - page 4

    4 AIR REQUIREMENTS Dilution air temperature must be 100°F or less. In calculating the free area of a vent opening, the blocking effect of screens, louvers and grills should be considered. Screens shall not be of a mesh smaller than 1/4 inch square. If the free area is not known, the current edition of National Fuel Gas Code ANSI Z223.1/NFP A 54 re ...

  • State Water Heaters CCVIT PR6 50 - page 5

    5 CAUTION In cold climates provide protection against freeze-up. THE HEA TER SHOULD BE LOCA TED IN AN AREA WHERE LEAKAGE OF THE T ANK OR CONNECTIONS WILL NOT RESUL T IN DAMAGE TO THE AREA ADJACENT TO THE HEA TER OR TO LOWER FLOORS OF THE STRUCTURE. When such locations cannot be avoided, a suitable drain pan should be installed under the heater , se ...

  • State Water Heaters CCVIT PR6 50 - page 6

    6 T o prevent damage, care must be taken not to apply too much torque when attaching gas supply pipe to gas valve inlet. The thermostat inlet has a pad for use with back up wrench. Apply joint compounds (pipe dope) sparingly and only to the male threads of pipe joints. Do not apply compound to the first two threads. Use compounds resistant to the a ...

  • State Water Heaters CCVIT PR6 50 - page 7

    7 3. A) MASONRY SIDE WALLS Chisel an opening approximately one half inch larger than the marked circle. B) WOODEN SIDE WALLS Drill a pilot hole approximately one quarter inch outside of the marked circle. This pilot hole is used as a starting point for a saws-all or sabre saw blade. Cut around the marked circle staying approximately one quarter inc ...

  • State Water Heaters CCVIT PR6 50 - page 8

    8 FIGURE 6 d . ) Splice field wiring into existing wiring using code authorized method (wire nuts, etc.). e. ) Be certain that neutral and line connections are not reversed when making these connections. f .) Close panel on the side of control box, make sure that access panel is secured shut. CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERV ...

  • State Water Heaters CCVIT PR6 50 - page 9

    9 INST ALLA TION OF VENT SYSTEM (Refer to Figures 3, 4, 5, 7 and 8 as guides). 1. Plan the route of the vent system. Layout the total vent system to use minimum of vent pipe and elbows. The vent piping should be vented downward away from the blower per the required codes. If the vent piping is sloped level or upwards away from the blower , then ade ...

  • State Water Heaters CCVIT PR6 50 - page 10

    10 VERTICAL VENT THROUGH ROOF This unit is approved for venting through the roof with the type vent terminal that is included with the unit. A proper flashing or “BOOT” should be used to seal the pipe where it exits the roof. The total vent system should not exceed that which is specified in the table on page 9. All of the pipe should be secure ...

  • State Water Heaters CCVIT PR6 50 - page 11

    11 RECOMMENDED BRUSH* SIZE FOR PRIMER AND CEMENT APPLICA TIONS Nominal Pipe Size Brush Width (IPS) (INS.) 2 1-1/2 3 1-1/2 - 2-1/2 *USE ONL Y NA TURAL BRISTLE 3 . MAKING THE JOINT A. Cutting Pipe must be squarely cut to allow for the proper interfacing of the pipe end and the fitting socket bottom. This can be accomplished with a miter box saw or wh ...

  • State Water Heaters CCVIT PR6 50 - page 12

    12 G . Cleanup and joint movement Remove all excess cement from around the pipe and fitting with a dry cotton rag. This must be done while the cement is still soft. The joint should not be disturbed immediately after the cementing procedure, and sufficient time should be allowed for proper curing of the joint. Exact drying time is difficult to pred ...

  • State Water Heaters CCVIT PR6 50 - page 13

    13 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. A . This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner . Do NOT try to light the burner by hand ...

  • State Water Heaters CCVIT PR6 50 - page 14

    14 TEMPERA TURE REGULA TION W ARNING THIS WA TER HEA TER IS EQUIPPED WITH AN ADJUST ABLE THERMOST A T TO CONTROL W A TER TEMPERA TURE. HOT W A TER TEMPERA TURES REQUIRED FOR AUT OMA TIC DISHW ASHER AND LAUNDR Y USE CAN CAUSE P AINFUL SCALDING WITH POSSIBLE SERIOUS AND PERMANENT INJURY . THE TEMPERA TURE A T WHICH INJURY OCCURS V ARIES WITH THE PERS ...

  • State Water Heaters CCVIT PR6 50 - page 15

    15 W A TER HEA TING IGNITION SEQUENCE (Make sure gas and electric power are connected properly) 1) The ignition control module is powered and monitors the system, waiting for a call for heat from the thermostat. 2) The thermostat calls for heat by reading a resistance value within a given range directly proportional to water temperature. 3) The con ...

  • State Water Heaters CCVIT PR6 50 - page 16

    16 VENTING SYSTEM HA VE VENTING SYSTEM CHECKED EVERY SIX MONTHS FOR OBSTRUCTIONS AND/OR DETERIORA TION IN VENT PIPING . BLOWER ASSEMBL Y MAINTENANCE CAUTION The air flow restrictor screen on the inlet side of the blower unit should be checked periodically for any accumulation of dust and lint. Any build up of dirt in the screen can result in insuff ...

  • State Water Heaters CCVIT PR6 50 - page 17

    17 TROUBLE SHOOTING Please check guidelines below. For your safety , water heater service should be performed only by a qualified service technicia n. Read the GENERAL SAFETY INFORMA TION section first. PROBLEM SOLUTION An open earth ground circuit to the 1. Check that the earth ground connection is ignition system. properly connected. 2. Check tha ...

  • State Water Heaters CCVIT PR6 50 - page 18

    18 TROUBLE SHOOTING (Continued) PROBLEM CAUSE SOLUTION 1) Blower will not run. A) “ON/OFF” control switch turned off. Turn switch to the “ON” position. B) Blower unplugged. Plug blower back into 1 15 V ac. outlet. C) No power at outlet. Repair service to outlet. D) Thermostat defective. Replace thermostat. E) Control harness defective. Repl ...

  • State Water Heaters CCVIT PR6 50 - page 19

    19 THIS W ARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONL Y . If the glass lined tank in this water heater shall prove upon examination by S t ate W ater Heaters (the warrantor) to have leaked during the warranty period in normal residential use, due to natural corrosion from potable water therein, the warrantor will furnish the ORIGINAL OWNER a re ...

  • State Water Heaters CCVIT PR6 50 - page 20

    20 500 LINDAHL P ARKWA Y ASHLAND CITY , TN 37015 www.statewaterheaters.com ...

Производитель State Water Heaters Категория Water Heater

Документы, которые мы получаем от производителя устройства State Water Heaters CCVIT PR6 50 мы можем разделить на несколько групп. Это в частности:
- технические чертежи State Water Heaters
- инструкции обслуживания CCVIT PR6 50
- паспорта изделия State Water Heaters
- информационные брошюры
- энергетические этикетки State Water Heaters CCVIT PR6 50
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания State Water Heaters CCVIT PR6 50.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа State Water Heaters CCVIT PR6 50, инструкции обслуживания, короткие инструкции или инструкции пользователя State Water Heaters CCVIT PR6 50. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия State Water Heaters CCVIT PR6 50.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства State Water Heaters CCVIT PR6 50, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании State Water Heaters CCVIT PR6 50 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей State Water Heaters CCVIT PR6 50.

Полная инструкция обслуживания State Water Heaters, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией State Water Heaters CCVIT PR6 50 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания State Water Heaters CCVIT PR6 50, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся State Water Heaters CCVIT PR6 50, которое найдем в данном документе
3. Советы по использованию основных функций устройства State Water Heaters CCVIT PR6 50 - которые должны облегчить нам первые шаги во время использования State Water Heaters CCVIT PR6 50
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем State Water Heaters CCVIT PR6 50
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра State Water Heaters CCVIT PR6 50 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся State Water Heaters CCVIT PR6 50?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с State Water Heaters CCVIT PR6 50, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с State Water Heaters CCVIT PR6 50 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)