  • Bay Technical Associates DS2-RPC - page 1

    DS Series Manual DATA SWITCH – Remote Power Controller DS2-RPC DS4-RPC DS4D-RPC BayTech Manual Publication Revision, May 2008 ...

  • Bay Technical Associates DS2-RPC - page 2

    DS-RPC Manual 2 Copyright 2007 by Bay Technical Associates, Inc. BayTech, is a registered trademarks of Bay Technical Associates, Inc. Windows 2000®, Windows XP® are products and registered trademark of Microsoft Corporation. Tera Term is a product and regist ered trademark of Vector, Inc. ...

  • Bay Technical Associates DS2-RPC - page 3

    DS-RPC Manual 3 ABOUT THIS OWNER’S MANUAL ........................................................................................................4 Connection Description ......................................................................................................... ..............5 Installation........................................... ...

  • Bay Technical Associates DS2-RPC - page 4

    DS-RPC Manual 4 ABOUT THIS OWNER’S MANUAL This document provides information required for installing and operating your Bay Tech equipment. It should allow the user to connect to, power up, and access an applications m enu where peripheral equipment can be controlled. We recommend readi ng this m anual carefully, while placing special emphasis on ...

  • Bay Technical Associates DS2-RPC - page 5

    DS-RPC Manual 5 Connection Description BayTech's Host communication module determines the t ype of interface that c ontrols user access to the DS Series data switch and other DS Series conn ected modules. The Host module is a system data controller that direct s operations between this base unit, sy stem modules and ex ternally connected devic ...

  • Bay Technical Associates DS2-RPC - page 6

    DS-RPC Manual 6 CAUTION: Before removing or replacing any modules, turn off main power switch located on the DS-Series Base Unit. Communication to the DS-Series Data Switch will be disru pted while power is off. CAUTION : For PERMANENTLY CONNECTED EQUI PMENT, a readily accessible disconnect device (Circuit Breaker rated not to ex ceed the amperage ...

  • Bay Technical Associates DS2-RPC - page 7

    DS-RPC Manual 7 QUICK ST ART : DS-RPC by Bay Technical Associates For those Administrators who have requested the bare minimum for this type of equipment, follow these steps exactly. If this is a new unit shipped directly from Baytech, follow the steps. If this is a previously own unit, perform a factory reset to cl ear out any users and passwords ...

  • Bay Technical Associates DS2-RPC - page 8

    DS-RPC Manual 8 Figure 1 NOTE: to get to the DS-RPC menu select the DS-RPC option and then ty pe ‘config’ at the prompt. Figure 2 Select manage users option and select A dd User. The following menu is displayed. NOTE: the first assigned user will be the ‘adm in user’ for the outlets. Figure 3 Enter new user name, than select th e user to a ...

  • Bay Technical Associates DS2-RPC - page 9

    DS-RPC Manual 9 Figure 4 Manage Users Select “Manage Users,” from the m ain menu allows the admin user to add and delete users, change passwords, and change the outlet list that determines an outlet user’s acces s to prescribed outlets. The following menu appears: Add User: Add a user. If the “Add user” option is NOT present than the maxi ...

  • Bay Technical Associates DS2-RPC - page 10

    DS-RPC Manual 10 Cabling RJ-45 Cables and Adapters Signal RS-232 Port (DS) RS-232 Port (RPC) COM Port DE-9 Pin COM Port DB-25 Pin DTR 1 1 4 20 DSR GND 2 2 1 GND RTS 3 3 7 5 CTS TxD 4 4 3 2 RxD RxD 5 5 2 3 TxD DSR 6 N/C 6 6 DTR GND 7 7 5 7 GND CTS 8 8 4 RTS DTR 4 DCD DCD 8 1 8 DTR RI 9 22 9FRJ45PC-4 RJ08X007 Figures 1 and 2 provide vi sual represent ...

  • Bay Technical Associates DS2-RPC - page 11

    DS-RPC Manual 11 Opening Menu S t atus IMPORTANT: The Factory default serial communications parameters are 9600 bps, 8 data bits, 1 stop bit, and no parity. NOTE: The configuration menu is dependent on the specific host module installed. If you have a proper connection to the unit upon power-up or unit re set, you should see something similar to th ...

  • Bay Technical Associates DS2-RPC - page 12

    DS-RPC Manual 12 HELP Typing ‘Help’ at the DS prompt w ill display a list of commands to ch ange the state of the outlets, unit configuration, and intern al sensor measurem ents. Receptacle Controls On, Off, Reboot, Lock, and Unlock are comm ands to control the individual outlets. From the (DS-RPC >) prompt, enter one of th e following comm ...

  • Bay Technical Associates DS2-RPC - page 13

    DS-RPC Manual 13 The REBOOT n command will reboot or reset equipment attached to correspond ing recep tacle(s). When the command to REBOOT (n) is sent from the DS-RPC > prompt, the DS powers ‘ Off ’ the corresponding outlet(s) for approximate ly 10 seconds, then powers them ‘ On ’ in sequence. This command only works on outlets which wer ...

  • Bay Technical Associates DS2-RPC - page 14

    DS-RPC Manual 14 Logging Out To logoff from the unit type Logout, Logoff, or Exit at the prompt. Logging out may not close the session. Current User Password: To change the current user’s password, type ‘ password ’ at the prom pt and the DS will respond: If the current user alread y has a password the DS will respond: NOTE: If you do not hav ...

  • Bay Technical Associates DS2-RPC - page 15

    DS-RPC Manual 15 Manage Users Select “Manage Users,” from the m ain menu allows the admin user to add and delete users, change passwords, and change the outlet list that determines an outlet user’s acces s to prescribed outlets. The following menu appears: If this is not an initial setup and an outlet user has been added, they will be shown i ...

  • Bay Technical Associates DS2-RPC - page 16

    DS-RPC Manual 16 Select 2) Remove Outlet(s) to remove an outlet from a user. The DS-RPC will display the following: Type the number of the outlet to be removed from the user’s access. For exam ple, if you want to remove Outlet 2 from the engineer’s access, enter the num ber 2, followed by <cr>. If you want to remove Outlets 2, 5, and 8 en ...

  • Bay Technical Associates DS2-RPC - page 17

    DS-RPC Manual 17 Rename a User: Select R), “Rename user”, from the User Management Menu, the DS unit responds: Enter the number that corresponds to the user to be renamed, fo llowed by <cr>. The DS unit responds: The DS Series redisplays the User Management Menu with the renamed user. Change Outlet Name Select “Change Outlet Name” fro ...

  • Bay Technical Associates DS2-RPC - page 18

    DS-RPC Manual 18 Default setting is Enabled. If the Enable/Disable Status Menu feature is dis abl ed, only the DS> prompt appears, else the following status menu appears. Change Unit ID From the configuration menu select “C hange Unit ID”. The DS will resp ond: The default ID is a ‘ Blank ’. Change Alarm Threshold The Current Alarm Thres ...

  • Bay Technical Associates DS2-RPC - page 19

    DS-RPC Manual 19 DS-RPC Factory Reset: To reset the DS-RPC unit to factor y default is to reset the power si de of the unit. Use the following instructions: Hardware Rev. lower than H2.0 * 1. Remove the top lid of the DS-RPC chassis. 2. Locate jumper J15 or JP1 (depending on which unit you have) in the center of the receptacle board. (This is a two ...

  • Bay Technical Associates DS2-RPC - page 20

    DS-RPC Manual 20 BayT ech Product W arranty Bay Technical Associates (BayTech) warrants that it s products will be free from defects in m aterials and workmanship under normal use for a period of two years from date of purchase (or from date of shipment from BayTech if proof of purchase is not provided). During this warranty period, BayTech shall, ...

  • Bay Technical Associates DS2-RPC - page 21

    DS-RPC Manual 21 Technical Support BayTech offers Tech Support for the lifetime of the product. A staff of Applic ations Engineers is on duty to assist with installation, set up or operation issues. Suppor t is available from 8:00 a.m. to 5 p.m . (CST or CDT), Monday through Friday at the phone numbers or website provided below. Please have the fol ...

  • Bay Technical Associates DS2-RPC - page 22

    DS-RPC Manual 22 Return Authorization Process: 1. Contact BayTech to get a Return Authorization (RA) Number. IMPORTANT: BayTech will not accept any returns without an RA number. 2. Package the unit carefully in its original packag ing or similar packaging. The warranty does not cover damage sustained during shipment. Enclos e a letter with name, ad ...

Производитель Bay Technical Associates Категория Switch

Документы, которые мы получаем от производителя устройства Bay Technical Associates DS2-RPC мы можем разделить на несколько групп. Это в частности:
- технические чертежи Bay Technical Associates
- инструкции обслуживания DS2-RPC
- паспорта изделия Bay Technical Associates
- информационные брошюры
- энергетические этикетки Bay Technical Associates DS2-RPC
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Bay Technical Associates DS2-RPC.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Bay Technical Associates DS2-RPC, инструкции обслуживания, короткие инструкции или инструкции пользователя Bay Technical Associates DS2-RPC. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Bay Technical Associates DS2-RPC.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Bay Technical Associates DS2-RPC, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Bay Technical Associates DS2-RPC пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Bay Technical Associates DS2-RPC.

Полная инструкция обслуживания Bay Technical Associates, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Bay Technical Associates DS2-RPC - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Bay Technical Associates DS2-RPC, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Bay Technical Associates DS2-RPC, которое найдем в данном документе
3. Советы по использованию основных функций устройства Bay Technical Associates DS2-RPC - которые должны облегчить нам первые шаги во время использования Bay Technical Associates DS2-RPC
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Bay Technical Associates DS2-RPC
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Bay Technical Associates DS2-RPC в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Bay Technical Associates DS2-RPC?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Bay Technical Associates DS2-RPC, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Bay Technical Associates DS2-RPC со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)