    Page 1 RH-50-6 Shown INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL VENTED ROOM HEA TER MODELS RH-50-6 RH-65-6 RH-50C-1 RH-65C-1 W ARNING: If not installed, operated and main- tained in accordance with the manufactur er’s in- structions, this product could expose you to sub- stances in fuel or from fuel combustion which can cause death or serio ...

  • Empire Comfort Systems RH50C-1 - page 2

    Page 2 T ABLE OF CONTENTS Important Safety Information ................................................................................................. 3 Safety Information for Users of LP Gas ................................................................................. 4 Introduction ........................................................... ...

  • Empire Comfort Systems RH50C-1 - page 3

    Page 3 IMPOR T ANT SAFETY INFORMA TION THIS IS A HEA TING APPLIANCE DO NOT OPERA TE THIS APPLIANCE WITHOUT FRONT P ANEL INST ALLED. • Du e to hi gh tem per atu re s, the r oom hea ter sho uld be loc ate d out of traffic and away from furnitur e and draperies. • Children and adults should be alerted to the hazards of high surface temperature an ...

  • Empire Comfort Systems RH50C-1 - page 4

    Page 4 SAFETY INFORMA TION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fir es and explosions. In its natural state, propane is odorless and colorless. Y ou may not know all the following safety precau - tions which can protect both you and your family fr om an ac - cident. Read them carefully now , then review them poi ...

  • Empire Comfort Systems RH50C-1 - page 5

    Page 5 INTRODUCTION Introduction Always consult your local Building Department regarding regu- lations, codes or ordinances which apply to the installation of a vented room heater . Instructions to Installer 1. Installer must leave instruction manual with owner after instal - lation. 2. Installer must have owner fill out and mail warranty card sup ...

  • Empire Comfort Systems RH50C-1 - page 6

    Page 6 GAS SUPPL Y Recommended Gas Pipe Diameter Pipe Length (Feet) Schedule 40 Pipe Inside Diameter T ubing, T ype L Outside Diameter Nat. LP Nat. LP 0-10 1/2” 1.3cm 3/8” 1.0cm 1/2” 1.3cm 3/8” 1.0cm 10-40 1/2” 1.3cm 1/2” 1.3cm 5/8” 1.6cm 1/2” 1.3cm 40-100 1/2” 1.3cm 1/2” 1.3cm 3/4” 1.9cm 1/2” 1.3cm 100-150 3/4” 1.9cm 1/2? ...

  • Empire Comfort Systems RH50C-1 - page 7

    Page 7 CLEARANCES Clearances: When facing the front of the room heater the mini- mum clearances to combustible construction (material) are the following: Left side - 6 inches (152mm) Right side - 6 inches (152mm) Recommend 18 inches (457mm) on left side for servicing Do not install in alcove or closet. No horizontal projection above heater permitte ...

  • Empire Comfort Systems RH50C-1 - page 8

    Page 8 VENT SAFETY SHUTOFF SYSTEM This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system. This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air . This room heater is equipped with a vent safety switch. ...

  • Empire Comfort Systems RH50C-1 - page 9

    Page 9 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the ? ...

  • Empire Comfort Systems RH50C-1 - page 10

    Page 10 PILOT FLAME CHARACTERISTICS The correct flame will be almost horizontal, blue and will extend past the thermocouple 1/4” (6mm). The flame will surround the thermocouple just below the tip. On Propane (LP-gas) slight yellow might occur where the pilot flame and the burner flame meet. Natural gas pilots require adjusting when the inlet ...

  • Empire Comfort Systems RH50C-1 - page 11

    Page 1 1 MAINTENANCE Cleaning Pilot Burner After use, cleaning of the pilot burner may be required for the proper flame. The pilot orifice can be cleaned with high pressure air or by placing under running water . Pilot orifice must be dry before replacement. Use a pipe cleaner to clean inside the pilot after the pilot orifice has been removed. ...

  • Empire Comfort Systems RH50C-1 - page 12

    Page 12 HOW TO ORDER REP AIR P AR TS Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor . Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number . When ordering parts, first obtain the ...

  • Empire Comfort Systems RH50C-1 - page 13

    Page 13 P AR TS VIEW RH-50 & RH-65 12822-4-0806 ...

  • Empire Comfort Systems RH50C-1 - page 14

    Page 14 P AR TS LIST RH-50C & RH-65C PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. INDEX NO. P AR T NUMBER DESCRIPTION INDEX NO. P AR T NUMBER DESCRIPTION 1 11723 Diverter Assembly 18 R-6126 Electrode and W ire Assembly 2 RH-802 Down Draft Shield (RH-50C-1 NA T & LPG) 19 1 1712 Pil ...

  • Empire Comfort Systems RH50C-1 - page 15

    Page 15 P AR TS VIEW RH-50C & RH-65C 12822-4-0806 ...

  • Empire Comfort Systems RH50C-1 - page 16

    Page 16 OPTIONAL BLOWER INST ALLA TION INSTRUCTIONS FRB-3 For V ented Room Heaters Models RH-50-(1, 2, 3, 4, 5, 6) RH-50C-1 RH-65-(1, 2, 3, 4, 5, 6) RH-65C-1 Figure 1 Figure 2 Figure 3 Figure 4 Installing Optional Blower 1. Remove rear shield (2 screws) and bottom reflector (4 screws). (See Figure 1) 2. Align blower cushion with bottom assembly ai ...

  • Empire Comfort Systems RH50C-1 - page 17

    Page 17 Attention: W iring harness on blower is factory assembled and installed. If wiring harness becomes disassembled, use the fol- lowing steps to reassemble the wiring harness. 1. Attach (1) pin terminal from black (hot) wire, smooth insulation on cord set to (1) socket terminal on fan control assembly . 2. Attach (1) pin terminal from black (n ...

  • Empire Comfort Systems RH50C-1 - page 18

    Page 18 SER VICE NOTES 12822-4-0806 ...

  • Empire Comfort Systems RH50C-1 - page 19

    Page 19 SER VICE NOTES 12822-4-0806 ...

  • Empire Comfort Systems RH50C-1 - page 20

    Page 20 SER VICE NOTES Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com 12822-4-0806 ...

Производитель Empire Comfort Systems Категория Electric Heater

Документы, которые мы получаем от производителя устройства Empire Comfort Systems RH50C-1 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Empire Comfort Systems
- инструкции обслуживания RH50C-1
- паспорта изделия Empire Comfort Systems
- информационные брошюры
- энергетические этикетки Empire Comfort Systems RH50C-1
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Empire Comfort Systems RH50C-1.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Empire Comfort Systems RH50C-1, инструкции обслуживания, короткие инструкции или инструкции пользователя Empire Comfort Systems RH50C-1. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Empire Comfort Systems RH50C-1.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Empire Comfort Systems RH50C-1, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Empire Comfort Systems RH50C-1 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Empire Comfort Systems RH50C-1.

Полная инструкция обслуживания Empire Comfort Systems, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Empire Comfort Systems RH50C-1 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Empire Comfort Systems RH50C-1, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Empire Comfort Systems RH50C-1, которое найдем в данном документе
3. Советы по использованию основных функций устройства Empire Comfort Systems RH50C-1 - которые должны облегчить нам первые шаги во время использования Empire Comfort Systems RH50C-1
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Empire Comfort Systems RH50C-1
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Empire Comfort Systems RH50C-1 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Empire Comfort Systems RH50C-1?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Empire Comfort Systems RH50C-1, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Empire Comfort Systems RH50C-1 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)