Инструкция обслуживания Chicago Electric 68987

20 страниц 3.28 mb
Скачать

Перейти на страницу of 20

Summary
  • Chicago Electric 68987 - page 1

    Visit our website at: http://www .harborfreight.com Email our technical support at: tech@harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 201 1 by Harbor Freight T ools ® . All rights reserved. No portion of this manual or any artwork contained herein ma ...

  • Chicago Electric 68987 - page 2

    Page 2 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP T able of Contents Safety ......................................................... 2 Specifications ............................................. 8 Setup .......................................................... 8 Operation ................. ...

  • Chicago Electric 68987 - page 3

    Page 3 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP Electrical safety 1. Power tool plugs must match the outlet. Never modify the plug in any way . Do not use any adapter plugs with grounded power tools. Unmodified plugs and matching outlets will reduce risk of electric shock. 2. A void body co ...

  • Chicago Electric 68987 - page 4

    Page 4 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP Power tool use and care 1. Do not force the power tool. Use the correct power tool for your application. The correct power tool will do the job better and safer at the rate for which it was designed. 2. Do not use the power tool if the switch ...

  • Chicago Electric 68987 - page 5

    Page 5 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP 13. Never use damaged or incorrect blade washers or bolt. The blade washers and bolt were specially designed for your saw , for optimum performance and safety of operation. 14. Do not use dull or damaged blades. 15. Blades must be rated to at ...

  • Chicago Electric 68987 - page 6

    Page 6 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP Grounding TO PREVENT ELECTRIC SHOCK AND DEA TH FROM INCORRECT GROUNDING WIRE CONNECTION: Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the ...

  • Chicago Electric 68987 - page 7

    Page 7 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP Extension Cords 1. Grounded tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord. 2. As the distance from the supply outlet increases, you must use a heavier gauge extension cord. ...

  • Chicago Electric 68987 - page 8

    Page 8 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP Specifications Electrical Rating 120V~ / 60Hz / 8.5A Motor No Load Speed 1 1,000 RPM Blade  Arbor  Note: For additional information regarding ...

  • Chicago Electric 68987 - page 9

    Page 9 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP Operating Instructions Read the ENTIRE IMPORT ANT SAFETY INFORMA TION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. T ool Set Up TO PREVENT SERIOUS INJUR Y FROM ACCID ...

  • Chicago Electric 68987 - page 10

    Page 10 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP Setting the Cutting Depth The Depth Adjustment Dial sets the cutting depth of the blade. The Dial has settings for three sizes of biscuits (0, 10 or 20), and an “M” setting which is the maximum depth that the tool can cut. T o set the too ...

  • Chicago Electric 68987 - page 11

    Page 1 1 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP Setting the Fence Angle T o adjust the fence angle to anywhere from 0º to 90º: 1. Loosen the Angle Locking Knob and rotate the Angle Fence until the desired angle is set on the Angle Ruler . 2. T ighten the Angle Locking Knob. 0 1 5 3 0 4 ...

  • Chicago Electric 68987 - page 12

    Page 12 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP General Operating Instructions Locking T rigger The Biscuit Joiner has a safety lock mechanism to prevent accidentally turning the unit on. Y ou can either turn the tool on and lock it on, or turn it on so that it only stays on while the T ri ...

  • Chicago Electric 68987 - page 13

    Page 13 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP Figure 9 Miter Joints T -Joints Joining Edge-to-Edge Cuts Butt Joints T ypical T ypes of Joints Plan the biscuit slot at a point at least 2-1/2" from the outer edge of the board. Allow at least 1" between slots in multiple plate app ...

  • Chicago Electric 68987 - page 14

    Page 14 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP Maintenance and Servicing Procedures not specifically explained in this manual must be performed only by a qualified technician. TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: T urn the Power Switch of the tool off and unplug the too ...

  • Chicago Electric 68987 - page 15

    Page 15 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP T roubleshooting Problem Possible Causes Likely Solutions T ool will not start. 1. Cord not connected. 2. No power at outlet. 3. T ool’s thermal reset breaker tripped (if equipped). 4. Internal damage or wear . (Carbon brushes or switch, fo ...

  • Chicago Electric 68987 - page 16

    Page 16 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP Part Description Qty 1 Bearing Set 1 2 Bearing 60017 1 3 Armature 1 4  2 5 Screw M4x10 2 6 Bearing 60100 1 7 Spindle Lock Button 1 8 Spring 1 9 Gear Box 1 10 Screw 4 11 ? ...

  • Chicago Electric 68987 - page 17

    Page 17 For technical questions, please call 1-800-444-3353. Item 68987 SAFETY OPERA TION MAINTENANCE SETUP Assembly Diagram ...

  • Chicago Electric 68987 - page 18

    Page 18 For technical questions, please call 1-800-444-3353. Item 68987 Record Product’ s Serial Number Here: Note: If product has no serial number , record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only , and are not available individually as replacement parts. ...

  • Chicago Electric 68987 - page 19

    Page 19 For technical questions, please call 1-800-444-3353. Item 68987 Limited 90 Day W arranty Harbor Freight T ools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days fro ...

  • Chicago Electric 68987 - page 20

    3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 9301 1 • (800) 444-3353 ...

Производитель Chicago Electric Категория Biscuit Joiner

Документы, которые мы получаем от производителя устройства Chicago Electric 68987 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Chicago Electric
- инструкции обслуживания 68987
- паспорта изделия Chicago Electric
- информационные брошюры
- энергетические этикетки Chicago Electric 68987
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Chicago Electric 68987.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Chicago Electric 68987, инструкции обслуживания, короткие инструкции или инструкции пользователя Chicago Electric 68987. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Chicago Electric 68987.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Chicago Electric 68987, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Chicago Electric 68987 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Chicago Electric 68987.

Полная инструкция обслуживания Chicago Electric, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Chicago Electric 68987 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Chicago Electric 68987, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Chicago Electric 68987, которое найдем в данном документе
3. Советы по использованию основных функций устройства Chicago Electric 68987 - которые должны облегчить нам первые шаги во время использования Chicago Electric 68987
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Chicago Electric 68987
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Chicago Electric 68987 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Chicago Electric 68987?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Chicago Electric 68987, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Chicago Electric 68987 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)