    IMPORTANT FOR FUTURE REFERENCE I ----LLL-- Please complete this informa- tion and retain this manual for the life of the equipment. MODEL # SERIAL # A MIDDLEBY COMPANY DATE PURCHASED OWNER’S MANUAL INSTALLATION USER’S GUIDE SERVICE PARTS DEEP FAT FRYER FRONT MANIFOLD -SECTIONAL RANGE MATCH MODELS: 1436,1442; l&36,16-42 FREE STANDING - RESTA ...

  • Southbend 14-42 - page 2

    Congratulations! You have just purchased one of the finest pieces of heavy-duty, commercial cooking equipment on the market today. You will find that your new equipment, like all Southbend equipment, has been designed and manufactured to some of the toughest standards in the industry - those of Southbend Corporation. Each piece of Southbend equipme ...

  • Southbend 14-42 - page 3

    t--a--- --r FRONT VIEW DIMENSIONS: DEEP FAT FRYER INSTALLATION SPECIFICATIONS TOP VIEW SIDE VIEW ( ) = Millimeters NOTEI Model 14 Fryers - 14” (356 mm) wide x 14” (356 mm) deep; Model 18 Fryers - 18” (457 mm) wide x 18” (457 mm) deep, ‘Model 14-32 comes standard with a shelf splasher- overall height is 56.5” (1435 mm). *Model 14-32 only ...

  • Southbend 14-42 - page 4

    INSTALLATION WARNINGz THESE PROCEDURES MUST BE FOLLOWED BY QUALIFIED PERSONNEL OR WARRANTY WILL BE VOIDED. I GENERAL: The unit, when installed, must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-Latest Edition. Canadian installation must comply with CAN/CGA-B149.1 Natural Gas Installation ...

  • Southbend 14-42 - page 5

    INSTALLATION t W-G: THESE PROCEDURES MUST BE FOLLOWED BY QUALIFIED PERSONNEL OR WARRANTY WILL BE VOIDED. SCREW - 1146201 1174264 - WlTH BRAKE 1174265 - Wl-lHOUT BRAKE j==, PAD - 1172650 i B i w LEG - 1174260 CASTER INSTALLATION LEG INSTALLATION LEGS OR OPTIONAL CASTERS: 1. A set of legs or casters are packed in the unit. A threaded receptacle is fa ...

  • Southbend 14-42 - page 6

    INSTALLATION WARNING: THESE PROCEDURES MUST BE FOLLOWED BY QUALIFIED PERSONNEL OR WARRANTY WILL BE VOfDED. GAS CONNECTIONS: The AGA. serial plate located on the back of the door (upper left corner> indicates the type of gas your unit is equipped to burn. Do Not connect to any other gas type. These models are design certified for operation on N ...

  • Southbend 14-42 - page 7

    INSTALLATION B. MODELS 1442,1436,18-42 and 18-36 INDIVIDUAL UNITS 1. Remove valve panel. 2. Use a long spirit level four ways; across the front top rail and rear collar plate, and along each edge. 3. (a) For units without a rear gas connection connect the gas supply to the right or left side of the manifold. Be sure to cap the unused side. (b) For ...

  • Southbend 14-42 - page 8

    INSTALLATION WARNING THESE PROCEDURES MUST BE FOLLOWED BY QUALIFIED PERSONNEL OR WARRANTY WILL BE VOIDED. MOUNTlNG SHELF OR BACKSPLASH 1. 2. 3. 4. (SECTIONAL ONLY) INSTALLATlON INSTRUCTIONS MODELS: 14-36,14-42, l&36,16-42 Front panel “A” is fastened with six (6) sheet metal screws. Remove screws and panel is loose. Remove nuts and lock wa ...

  • Southbend 14-42 - page 9

    INSTALLATION t PERFORMANCE CHECH: The following items should be checked before or within the first 30 days of operation by a qualified service technician. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Verify correct gas type. Gas pressure. Check gas supply connections. Internal gas connections. Internal electrical connections. Pilots - adjustment and igni ...

  • Southbend 14-42 - page 10

    USER’S GUIDE LIMITED WARRANTY Southbend warrants that the equipment, as supplied by the factory to the original purchasers, is free from defects in materials and workmanship. Should any part thereof become defective as a result of normal use within the period and limits defined below, then at the option of Southbend such parts will be repaired or ...

  • Southbend 14-42 - page 11

    ii OPERATION WARNING THESE PROCEDURES MUST BE FOLLOWED BY QUALIFIED PERSONNEL OR WARJMNTY WILL BE VOIDED. THEORY OF OPERATION: All Southbend Fryers are immersion tube fryers. This is the most efficient method of transmitting heat into the frying compound. The tubes are actually large heat exchangers. Each tube is heated by a burner at its front, wh ...

  • Southbend 14-42 - page 12

    OPERATION 8 C. FtELIGHITINGz 1. Shutoffallgas. 2. wait 5 minutes. 3. Repeat “LIGHTING” instructions in Section “A” CAUTION: IF YOU SMELL GAS DURING THE LIGHTING PROCEDURE, IMMEDLATELY SHUT OFF THE GAS SUPPLY UNTIL TUELEAUHAS BEEN CORRECTED. WARNING In the event of main burner ignition failure, a 5 minute purge period must be observed prior ...

  • Southbend 14-42 - page 13

    COOKING ...

  • Southbend 14-42 - page 14

    COOKING HINTS PERJTOFtMANCE: TYPICAL PRODUCTION 14"FRYExs Potatoes - Raw to finished 70 Lbs. per Hr. - Blanched to finished 285 Lbs. per Hr. Chicken -Raw to finished 45 Lbs. per Hr. -Blanched to finished 85 Lbs. per Hr. 18" FRYERS 115 Lbs. per Hr. 360 Lbs. per Hr. 60 Lbs. per Hr. 110 Lbs. per Hr. WARING: Adjustments and service work may b ...

  • Southbend 14-42 - page 15

    MAINTENANCE FRY KETTLE CLEANING WEEKLY: 1. Follow steps 1, 2, 3 and 4 above. 2. Close drain valve and fill kettle with a solution of warm water and a strong detergent or other strong cleanser. 3. Relight the fryer and bring the solution to a gentle boil for at least five minutes. 4. Turn off main burners and let the solution stand until the gum dep ...

  • Southbend 14-42 - page 16

    DEEP FAT FRYER SERVICE ADJUSTMENTS ’ / WARNING Adjustments and service work may be performed only by a qualified technician who is experienced in, and knowledgeable with, the operation of commercial gas cooking equipment. However, to assure your confidence, contact your Authorized Service Agency for reliable service, dependable advice or other as ...

  • Southbend 14-42 - page 17

    ADJUSTMENTS PRESSURE REGULATOR: The pressure regulator is factory set at 4 N W.C. for natural gas and 10 N WC. for propane gas. lb check the manifold pressure: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Turn thermostat “OFF” (lowest position) and Unitrol knob to “PILOT” setting. Remove pressure tap plug from burner manifold located directly above t ...

  • Southbend 14-42 - page 18

    ADJUSTMENTS / / GAS MANIFOLD NUMBER - BURNER TYPE PRESSURE PERUNIT RATE EA. TOTAL RATE ORIFICE BTUSfHR. BTUsiHR. SIZE 14-32 Main Nat. 4" W.C. 4 22,500 90,000 if44 - .086" dia. 14-42 Prop. 10" W.C. 4 22,500 90,000 #54 - .0024" dia. Nat. 4" WC 1 1436 900 900 #77 - .018" dia. Pilot r Prop. 10" W.C. 1 900 900 .Oll&quo ...

  • Southbend 14-42 - page 19

    ...

  • Southbend 14-42 - page 20

    DEEP FAT FRYER PARTS WARNING INSTALLATION OF OTHER THAN GENUINE SOUTHBEND PARTS WILL VOID THE WARRANTY ON THIS EQUIPMENT. The serial plate is located on the back of the door - upper left corner. Replacement parts may be ordered either through a Southbend Authorized Parts Depot or a South- bend Authorized Service Agency. When ordering, please supply ...

  • Southbend 14-42 - page 21

    PARTS KEY NO. PART NO. DESCRIPTION 1 1161318 FIIIFFXTFNSI~N ( , ’ 1 1160577 1 FLUEEXIENSION 1 1 1 1 1161399 1 FLUEEXTENSION(2975) 1 1 2 1 4440014 1 BASKETHANGERKIT 1 1 1 2 1 4440015 1 BASKETHANGERKIT 1 1 3 1 1161727 1 REARCOLLAR PlATEASM.wffILLER 1 1 3 1164891 COLLAR PLATEFlLLER(1127301) 4 P9181 FRYER BASW-m"J C’7E 4 P9184 FRYFRRASFI NOTSH ...

  • Southbend 14-42 - page 22

    USAGE KEY NO. PARTNO. DESCRIPTION 14-32 14-36 14-42 la36 i 1 1054800 MAIN SUPPLYTUBE - 5/8" 0.0. 1 1 1 1057412 MAINSUPPLYTUBE- 5/8" 0.0. 1 1 2 1064197 PlLOTASM.-NAT. GAS 1 1 1 1 1 r. GAS (.018m) 4 3 4 9 , 1054118 PILOT ORIFICE ONLY - NAl 2 1054196 PlLOTASM.- LPGAS 1nu111 PILOT ORIFICE ONLY - LP GAS (.Oll") " . --"I .'i ...

  • Southbend 14-42 - page 23

    PARTS MISCELLANEOUS PARTS NOT SHOWN IN PHOTOS ISAGE 18-4; PART NO. DESCRIPTIDN 14-32 14-36 1163223 VALVEPANEL-CHROME(UsedonBlackorStnls.Units) 1164640 VALVEPANEL-BLACK(1103802) 1164.541 VALVEPANEL-STNLS.STEEL(1103803) 1164542 VALVEPANEL-BLACK(1103804) 1164543 VALVEPANEL-STNLS.STEEL(1103805) 1161667 1 RIGHTBODYSIDE-BLACK 1161668 RIGHTBODYSIDE-STNLS. ...

  • Southbend 14-42 - page 24

    DEEP FAT FRYER I I A product with the Southbend name incorporates the best in durability and low maintenance. We all recognize however, that replacement parts and occasional professional service may be necessary to extend the useful life of this unit. When service is needed, contact a Southbend Authorized Service Agency, or your dealer. To avoid co ...

Производитель Southbend Категория Fryer

Документы, которые мы получаем от производителя устройства Southbend 14-42 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Southbend
- инструкции обслуживания 14-42
- паспорта изделия Southbend
- информационные брошюры
- энергетические этикетки Southbend 14-42
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Southbend 14-42.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Southbend 14-42, инструкции обслуживания, короткие инструкции или инструкции пользователя Southbend 14-42. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Southbend 14-42.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Southbend 14-42, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Southbend 14-42 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Southbend 14-42.

Полная инструкция обслуживания Southbend, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Southbend 14-42 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Southbend 14-42, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Southbend 14-42, которое найдем в данном документе
3. Советы по использованию основных функций устройства Southbend 14-42 - которые должны облегчить нам первые шаги во время использования Southbend 14-42
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Southbend 14-42
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Southbend 14-42 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Southbend 14-42?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Southbend 14-42, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Southbend 14-42 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)