    PC-CARD-DAS16/12AO Analog I/O and Digit al I/O Board User ’ s Guide Document Revision 1, April, 2007 © Copyright 2007, Measurement Computing Corporation ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 3

    Your new Measurement Computing product comes w ith a fantastic extra — Management committed to your satisfaction! Refer to www.mccdaq.com/execteam.html for the names, titles, and contact inform ation of each key executive at Measurement Computing. Thank you for choosing a Measurement Computing product—and congratulations! You own the finest, an ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 4

    Trademark and Copy right Information TracerDAQ, Universal Library, Harsh Environment Warranty, Measurement Computing Corpor ation, and the Measurement Computing logo are either trademarks or registered trademarks of M easurement Computing Corporation. Windows, Microsoft, and Visual Studio are either trademarks or registered trademarks of Microsoft ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 5

    Table of Contents Preface About this U ser's Gu ide .......................................................................................................................7 What you will learn from this user's guide ..................................................................................... .................... 7 Conventions in ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 6

    PC-CARD-DAS16/12AO User's Guide Power consumption .......................................................................................................................................... 24 Miscella neous .......................................................................................................................................... ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 7

    Preface About this User's Guide What you will learn from this user's guide This user's guide explai ns how to install, configure, and use t he PC-CARD-DAS16/12AO so that y ou get the most out of it s analog I/O, digita l I/O and counter features. This user' s guide also refers you to related documents avail able on our web site, ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 8

    Chapter 1 Introducing the PC-CARD-DAS16/12AO Overview: PC-CARD-DAS16/12AO features The PC-CARD-DAS16/12AO is a dat a acquisition and control board for IBM PC compatible com puters with PCMCIA type II sl ots. The PC-CARD-DAS16/12AO provi des 16 single-ended or 8 differential analog inputs, 12-bit A/D resoluti on, two analog outputs, four digi tal I/ ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 9

    PC-CARD-DAS16/12AO User's Guide Introducing the PC-CARD-DAS16/12AO Software features For information on t he features of Insta Cal and the other software i n cluded with your PC-C ARD- DAS16/12AO, refer to the Quick Start Guide that shipped with your device. The Quick Start Guide is also available in PDF at www.mccdaq.com /PDFmanuals/DAQ-Softw ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 10

    Chapter 2 Installing the PC-CARD-DAS16/12AO What comes with your PC-CARD-DAS16/12AO shipment? The following item s are shipped with the PC-CARD-DAS16/12AO. Hardware  PC-CARD-DAS16/12AO Additional documentation In addition to this hardware user's guide, you should also receive the Quick Start Guide (available in PDF at www.mccdaq.com /PDFman ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 11

    PC-CARD-DAS16/12AO User's Guide Installing the PC-CARD-DAS16/12AO Unpacking the PC-CARD-DAS16/12AO As with any electronic devi ce, you should take care while handling to avoid dam age from stat ic electricity . Before removing t h e PC-CARD-DAS16/12AO from its packaging, ground yourself using a wrist strap or by simpl y touching the com puter ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 12

    PC-CARD-DAS16/12AO User's Guide Installing the PC-CARD-DAS16/12AO 2. 3. o o Select the Hardware tab and click on the Devic e Manager butt on. Verify that "PCMC IA adapters" is list ed in the Device Manager. If you don’t find this entry, or if t he properties for the adapter indi cate "this device is not working," you need ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 13

    PC-CARD-DAS16/12AO User's Guide Installing the PC-CARD-DAS16/12AO Cabling Measurement C omputing offers two cabl es for connecting the PC-CAR D-DAS16/12AO to a screw-type terminal board or other si gnal conditioning interface board:  The CPCC-50F-39 cable: 39 inches (990 mm ) long; com patible with standard 50-pi n screw termi nal products. ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 14

    PC-CARD-DAS16/12AO User's Guide Installing the PC-CARD-DAS16/12AO Caution! Do not exceed the input specificati ons. There are no socketed or us er serviceable parts in a PC- CARD-DAS16/12AO. Check the specificat ions and input voltages before connecting any signals. CPCC-50F-39 50-pin female IDC connector . 50 49 2 1 Dot 50- pin mi cro con nec ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 15

    PC-CARD-DAS16/12AO User's Guide Installing the PC-CARD-DAS16/12AO C50FF-x The red stripe ident i fie s pin # 1 50-pin female IDC conne ctor 50-pi n female IDC conn ector 1 2 49 50 2 50 1 49 Figure 8. C50FF-x cable Details on the C50FF-x cable are available on our web site at www.mccdaq.com /cbicatalog/cbi p roduct.asp?dept_id=104&pf_id=136 ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 16

    Chapter 3 Programming and Developing Applications After following the i nstallation i nstructions in Chapte r 2, your board should now be install ed and ready for use. In general there may be no correspondence am ong regist ers for different boards. Software written at the register-level for other m odels does not function correctly with your board ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 17

    Chapter 4 Functional Details The 12-bit A/D converter provides a resoluti on of 1/4096 parts of full scale. The smallest reading of ful l scale (1 part in 4096) is called a Least Si gnificant Bit (LSB). Four bipolar and four unipol ar ranges may be set by software. These are: Analog input ranges Bipolar Unipolar Range Resolution Range Resolution ± ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 18

    PC-CARD-DAS16/12AO User's Guide Functional Details Triggering and transfer A trigger begins an acquisiti on/transfer cycle. Th ere are three ways to tr igger a PC-CAR D-DAS16/12AO: programma ble pacer, software, or external. The trigger source selection is progr amm able. The programmable pacer is the product of two 16-bit counters dividing a ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 19

    PC-CARD-DAS16/12AO User's Guide Functional Details Control R eg ister B A SE + 6h TRGPOL T RGSEL TR GCLR CLK2 CTR1 1/10 1/10 10 MHz OSC Tr i g g e r Logic TS1 TS0 MUX 1 0 3 2 1 0 S/W CONV ERT T r igge r Logic 39 40 41 47 44 45 42 CRT1 CLK CTR1 G A TE CTR1 O UT A/D INT E RNA L PA C ER O U T A/D P ACER GA TE A/D E XTE RN AL TRIG GER A/D EXTERNAL ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 20

    Chapter 5 Specifications Typical for 25 °C unless otherwise specified. Specifications in italic text are guaranteed by design. Analog input Table 1. Analog input specifications A/D converter type ADS7804 Resolution 12 bits Number of channels 16 single-ended / 8 differential, software selectable Input ranges ±10 V, ±5 V, ±2.5 V, ±1.25 V, 0 to 1 ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 21

    PC-CARD-DAS16/12AO User's Guide Specifications Table 3. Calibrated accuracy specifications le 3 Range Gain Error Offset Error DLE (Note 1) ILE (Note 1) All ranges ±1.0 max ±1.0 m ax ±1.0 max ±1.0 max Note 1: These are the intrinsic specifi cations of th e ADC. Software calibration may introduce a small additional am ount of linearity error ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 22

    PC-CARD-DAS16/12AO User's Guide Specifications Analog output section Table 6. Analog output specifications D/A converter type LTC1446 Resolution 12 bits Number of channels 2 Configuration Voltage output, single-ended Output Range ±10 V, ±5 V. Software selectable. Se lected range applies to both channels. D/A pacing Software Data transfer Pro ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 23

    PC-CARD-DAS16/12AO User's Guide Specifications Digital input/output Table 9. DIO specifications Digital type FPGA Number of I/O 4 Configuration One port, programmable 4 input / 4 output Input low voltage 0.8 V max Input high voltage 2.0 V min Output low voltage (IOL = 4 mA) 0.32 V max Output high voltage (IOH = -4 mA) 3.86 V min Absolute maxim ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 24

    PC-CARD-DAS16/12AO User's Guide Specifications Frequency accuracy 50 ppm Note 2: If you are not driving the gate of nter 1, it is strongly recom mended that it be connected to Power consumption Table 12. Power consum ption specifications +5V quiescent User Cou +5V (VDD). 85 mA typical, 125 mA max Miscellaneous Table 13. Miscellaneous specifica ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 25

    PC-CARD-DAS16/12AO User's Guide Specifications Table 17. Differential analog input mode pin out Pin Signal Name Pin Signal Name 1 AGND 26 DGND 2 CH0 HI 27 DIO0 3 CH0 LO 28 DIO1 4 CH1 HI 29 DIO2 5 CH1 LO 30 DIO3 6 CH2 HI 31 N/C 7 CH2 LO 32 N/C 8 CH3 HI 33 N/C 9 CH3 LO 34 N/C 10 CH4 HI 35 DA GND0 11 CH4 LO 36 DA OUT0 12 CH5 HI 37 DA GND1 13 CH5 ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 26

    Declaration of Conformity Manufacturer: Measurement C omputing Corporat ion Address: 10 Comm erce Way Suite 1008 Norton, MA 02766 USA Category: Electrical equipm ent for measurement, control and laborat ory use. Measurement Computing Corporation declares under sole responsibility that the product PC-CARD-DAS16/12AO to which this declaration relates ...

  • Measurement Specialties PC-CARD-DAS16/12AO - page 27

    Measurement Computing Corporation 10 Commerce Way Suite 1008 Norton, Massachusetts 02766 (508) 946-5100 Fax: (508) 946-9500 E-mail: info@mccdaq.com www.m cc daq .com ...

Производитель Measurement Specialties Категория Network Card

Документы, которые мы получаем от производителя устройства Measurement Specialties PC-CARD-DAS16/12AO мы можем разделить на несколько групп. Это в частности:
- технические чертежи Measurement Specialties
- инструкции обслуживания PC-CARD-DAS16/12AO
- паспорта изделия Measurement Specialties
- информационные брошюры
- энергетические этикетки Measurement Specialties PC-CARD-DAS16/12AO
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Measurement Specialties PC-CARD-DAS16/12AO.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Measurement Specialties PC-CARD-DAS16/12AO, инструкции обслуживания, короткие инструкции или инструкции пользователя Measurement Specialties PC-CARD-DAS16/12AO. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Measurement Specialties PC-CARD-DAS16/12AO.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Measurement Specialties PC-CARD-DAS16/12AO, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Measurement Specialties PC-CARD-DAS16/12AO пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Measurement Specialties PC-CARD-DAS16/12AO.

Полная инструкция обслуживания Measurement Specialties, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Measurement Specialties PC-CARD-DAS16/12AO - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Measurement Specialties PC-CARD-DAS16/12AO, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Measurement Specialties PC-CARD-DAS16/12AO, которое найдем в данном документе
3. Советы по использованию основных функций устройства Measurement Specialties PC-CARD-DAS16/12AO - которые должны облегчить нам первые шаги во время использования Measurement Specialties PC-CARD-DAS16/12AO
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Measurement Specialties PC-CARD-DAS16/12AO
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Measurement Specialties PC-CARD-DAS16/12AO в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Measurement Specialties PC-CARD-DAS16/12AO?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Measurement Specialties PC-CARD-DAS16/12AO, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Measurement Specialties PC-CARD-DAS16/12AO со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)