Инструкция обслуживания DMP Electronics XR6A

18 страниц 0.87 mb
Скачать

Перейти на страницу of 18

Summary
  • DMP Electronics XR6A - page 1

    LT-0464 (6/99) XR6A /XR10A /XR20A Command Processor TM Panels Installation Guide 6/10/26 Zone Burglar y/Fire/Access Control Panels with Built-in Communicator 2841 E. Industrial Drive Springfield, MO USA 65802-6310 A CN 087 480 279 : http://www. guardianalarms . net ...

  • DMP Electronics XR6A - page 2

    MODEL XR6A/XR10A/XR20A COMMAND PROCESSOR TM INST ALLA TION GUIDE COMPLIANCE STATEMENT The DMP Model XR6A, XR10A, and XR20A systems have been tested and comply with the requirements of CISPR22 Class B Electromagnetic Emissions, ACA Technical Standard TS001-1997 Electrical Safety, AS/NZS 3260-1993 including amendments 1 to 4 Electrical Safety, and AC ...

  • DMP Electronics XR6A - page 3

    T ABLE OF CONTENTS Section Page P anel Specifications ........................................................................................... 5 1.1 P o wer supply .................................................................................................... 5 1.2 Communication .............................................................. ...

  • DMP Electronics XR6A - page 4

    T ABLE OF CONTENTS Section Page P owered Zone f or 2-Wire Smoke Detectors .................................................... 15 11.1 T erminals 25 and 26 ....................................................................................... 15 Annunciator Outputs ................................................................................... ...

  • DMP Electronics XR6A - page 5

    Introduction XR6A/XR10A/XR20A Installation Guide 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Digital Monitoring Products Panel Specifications 1.1 Power supply Transformer Input: 16.5 VAC 40VA or 16.5 VAC 20VA Standby Battery: 12 VDC 7.0Ah (40VA transformer charges up to 2 batteries) Auxiliary Output: 12 VDC at 500mA Bell Ou ...

  • DMP Electronics XR6A - page 6

    Introduction XR6A/XR10A/XR20A Installation Guide Digital Monitoring Products 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Introduction 2.1 Description The DMP XR6A/XR10A/XR20A Command Processors are powerful 12 VDC burglary and fire communicator panels with battery backup. The XR10A/XR20A provide nine on-board burglary zones ...

  • DMP Electronics XR6A - page 7

    Introduction XR6A/XR10A/XR20A Installation Guide 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Digital Monitoring Products System Components 3.1 Description The DMP XR6A/XR10A/XR20A system is made up of an alarm panel with built in communicator, an enclosure, a 16.5 VAC transformer, and a 12 VDC 7.0 Ah battery. You can add up ...

  • DMP Electronics XR6A - page 8

    Introduction XR6A/XR10A/XR20A Installation Guide Digital Monitoring Products 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Figure 1: XR6A/XR10A/XR20A wiring diagram Page 4 Ref er to t he Com mand Proc ess orT M Pa n el Progr am m ing an d I n stalla t ion G uides for a com plete descr i ption of pr ogram m i n g i nstructi on ...

  • DMP Electronics XR6A - page 9

    Installation XR6A/XR10A/XR20A Installation Guide 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Digital Monitoring Products Installation 4.1 Mounting the enclosure The metal enclosure must be mounted in a secure, dry place to protect the panel from damage due to tampering or the elements. It is not necessary to remove the PC b ...

  • DMP Electronics XR6A - page 10

    Installation XR6A/XR10A/XR20A Installation Guide Digital Monitoring Products 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 4.2 Mounting keypads Security Command keypads have removable covers that allow you to easily mount the base to a wall or other flat surface using the screw holes provided on each corner. For mounting keyp ...

  • DMP Electronics XR6A - page 11

    Installation XR6A/XR10A/XR20A Installation Guide 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Digital Monitoring Products Secondary Power Supply 6.1 Battery terminals 3 and 4 Connect the black battery lead to terminal 4 on the panel and to the negative terminal of the battery. The negative terminal connects to the enclosure ...

  • DMP Electronics XR6A - page 12

    Installation XR6A/XR10A/XR20A Installation Guide Digital Monitoring Products 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 XR6A/XR10A/XR20A STANDBY BATTERY POWER CALCULATIONS Standby Current Alarm Current Command Processor Panel 50mA ______ mA 50mA ______ mA Active Zones 1-9 Qty _____ x 1.6mA ______ mA Qty _____ x *2mA ______ ...

  • DMP Electronics XR6A - page 13

    Installation XR6A/XR10A/XR20A Installation Guide 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Digital Monitoring Products Bell Output 7.1 Terminals 5 and 6 Nominal 12 VDC is supplied by terminal 5 on the panel to power alarm bells or horns. The output is rated for a maximum of 1.5 Amps with a 40VA transformer and 600mA with ...

  • DMP Electronics XR6A - page 14

    Installation XR6A/XR10A/XR20A Installation Guide Digital Monitoring Products 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Burglary Zones 10.1 Description The XR10A/XR20A terminals 12 to 24 are the nine burglary zones. For programming purposes, the zone numbers are 1 to 9. The zone configurations on terminals 12 to 24 are des ...

  • DMP Electronics XR6A - page 15

    Installation XR6A/XR10A/XR20A Installation Guide 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Digital Monitoring Products Powered Zone for 2-Wire Smoke Detectors 11.1 Terminals 25 and 26 A resettable 2-wire Class B powered zone is provided on terminals 25 (positive) and 26 (negative) of the panel. For programming purposes, t ...

  • DMP Electronics XR6A - page 16

    Installation XR6A/XR10A/XR20A Installation Guide Digital Monitoring Products 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Annunciator Outputs 12.1 Description The four annunciator outputs can be programmed to indicate the activity of the panel's zones or conditions occurring on the system. Annunciator outputs do not pro ...

  • DMP Electronics XR6A - page 17

    Installation XR6A/XR10A/XR20A Installation Guide 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Digital Monitoring Products Reset Jumpers J16 14.1 Description There are two reset jumpers located at the top right of the panel's circuit board labeled RESET. Momentarily shorting these jumpers allows you to reset the micropro ...

  • DMP Electronics XR6A - page 18

    Digital Monitoring Products 2841 E. Industrial Drive Springfield, MO 65802-6310 800-64104282 ...

Производитель DMP Electronics Категория Home Security System

Документы, которые мы получаем от производителя устройства DMP Electronics XR6A мы можем разделить на несколько групп. Это в частности:
- технические чертежи DMP Electronics
- инструкции обслуживания XR6A
- паспорта изделия DMP Electronics
- информационные брошюры
- энергетические этикетки DMP Electronics XR6A
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания DMP Electronics XR6A.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа DMP Electronics XR6A, инструкции обслуживания, короткие инструкции или инструкции пользователя DMP Electronics XR6A. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия DMP Electronics XR6A.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства DMP Electronics XR6A, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании DMP Electronics XR6A пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей DMP Electronics XR6A.

Полная инструкция обслуживания DMP Electronics, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией DMP Electronics XR6A - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания DMP Electronics XR6A, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся DMP Electronics XR6A, которое найдем в данном документе
3. Советы по использованию основных функций устройства DMP Electronics XR6A - которые должны облегчить нам первые шаги во время использования DMP Electronics XR6A
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем DMP Electronics XR6A
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра DMP Electronics XR6A в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся DMP Electronics XR6A?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с DMP Electronics XR6A, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с DMP Electronics XR6A со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)