    RS-422/485 PCI Card User Manual English No. 51200 ( 2 Port ) No. 51202 ( 4 Port ) No. 51204 ( 8 Port ) www .lindy .com © LINDY ELECTRONICS LIMITED & LIN DY -ELEKTRONIK GMBH - SEC OND EDITION (No v 2005) ...

  • Lindy RS-422/485 - page 2

    ...

  • Lindy RS-422/485 - page 3

     1.0 Introduction Thank you for purchasing the LINDY RS-422/485 Controller . This PCI serial card enables your computer to support serial RS-422/485 ports with 128Kbyte FIFO, Auto Identify and Switch RS-422/485 and ARSC™ technology .  2.0 Packing List Please check if the fo llowing items are present and in good condition upon opening the pa ...

  • Lindy RS-422/485 - page 4

     3.0 Features 1. Fully compliant with PCI S pecification V ersion 2.2 2. Supports both 64 Bit & 32 Bit PCI Bus and 3.3V & 5V connector keys. 3. High speed serial ports suppor t baud rates of up to 921.6Kbp s. 4. Provides a FIFO maximize size of 128Kbytes. The 128K FIFO can reduce CPU loading, improving system performance dramatically . 5 ...

  • Lindy RS-422/485 - page 5

     4.0 Specifications 4.1 Function Ty p e LINDY Indus trial Hos t Controller Mode of Operation Differential RS-422 Full-Duplex Bus T ransceivers RS-485 Half-Duplex RS-422 1 Driv er Drivers per Line RS-485 10 Drivers RS-422 10 Receivers Receivers per Line RS-485 32 Receivers 4.2 Hardware IC SUN1889 Controller UART (16C650 comp atible) Bus Interface ...

  • Lindy RS-422/485 - page 6

    4.4 Driver support Windows3.x/95/98SE/ME/NT/2000/XP/2003 Driver Support DOS, OS/2 , Linux 2.0.x / 2.2.x / 2.4.18 / 2.4.20 4.5 Dimensions 51200 120 × 80mm 51202 160 × 104mm Dimensions (W × D) (St d.Bracket:121mm) 51204 180 × 108mm 4.6 Regulatory Approvals Hardware CE, FCC Regulatory Approv als Sof t w are WHQL 4.8 System Requirements 1. Pentium ...

  • Lindy RS-422/485 - page 7

     6.0 Pin Assignments & Cable Wiring The pin assignments of the DB9 and DB25 Male port are stated as below: Type Signal DB9M DB25M TxD- 1 8 TxD+ 2 3 RxD+ 3 2 RxD- 4 20 RTS- 6 6 RTS+ 7 4 CTS+ 8 5 CTS- 9 22 RS-422 GND 5 7 Type Signal DB9M DB25M Data+ 2 3 Data- 1 8 RTS- 6 6 RTS+ 7 4 CTS+ 8 5 CTS- 9 22 RS-485 GND 5 7 - 5 - ...

  • Lindy RS-422/485 - page 8

    LINDY Serial Communication Boards hav e one DB37 female port for the 4 port version and one DB78 female port for t he 8 port version. The pin assignments of the DB37 female port and the DB78 female port are shown below and on the following page. LINDY DB37 female 4 Port Serial Communication Boards Pin Assignment Port Signal 1 2 3 4 TxD- 34 11 25 2 ...

  • Lindy RS-422/485 - page 9

    LINDY DB78 female 8 Port Serial Communication Boards Pin Assignment Port Signal 1 2 3 4 5 6 7 8 TxD- 21 6 30 15 60 45 69 54 TxD+ 1 25 10 34 40 64 49 73 RxD+ 2 26 11 35 41 65 50 74 RxD- 22 7 31 16 61 46 70 55 RTS- 3 27 12 36 42 66 51 75 RTS+ 24 9 33 18 63 48 72 57 CTS+ 4 28 13 37 43 67 52 76 CTS- 5 29 14 38 44 68 53 77 RS-422 GND 23 8 32 17 62 47 71 ...

  • Lindy RS-422/485 - page 10

    LINDY Serial Communication Boards feat ure a 1 x DB37 Male to 4 DB9 Male cable for the 4 port version, and a 1 x DB78 Male port to 8 x DB9 Male ports cable, for 8 port version. DB37 Male to 4 x DB9 or DB25 Male Cable DB78 Male to 8 x DB9 or DB25 Male Cable - 8 - ...

  • Lindy RS-422/485 - page 11

    6.1 Jumper Settings These cards feature built-in termination re sistors for each serial port. Y ou can modify the jumper settings (short the pins) to avoid impedance mismatch problems when operating under multi-drop transmission. When an electrical signal travels th rough two resistance junctions in a transmission line, the impedance mismat ch will ...

  • Lindy RS-422/485 - page 12

    7.0 Driver Installation 7.1 Windows 2000 / XP / 2003: On booting up, the system will detect the presence of the PCI Serial card and prompt for the driver installation wi zard. Please ignore this for known and insert the driver CD in your CD/DV D ROM drive. Run the setup file: : PCI IOwin2k and xpsetup.exe (1) Please click “ Next ” to continu ...

  • Lindy RS-422/485 - page 13

    (2) Y ou can select the folder location in which the driver is installed. Click Next ” to continue. (3)The Software Inst allation Notice will appear , please click “ Continue Anyway ”, and the system will install the driver automatically . (4) Please click “ Finish ” and eject the driver CD. - 1 1 - ...

  • Lindy RS-422/485 - page 14

    (5) Please go back to the “Found New Hardware Wizard” window . Select “ Inst all the sof tware automaticall y (Recommend) ” and click “ Next ”. (6) The system will search and inst all the appropriate I/O driver automatically . (7) The “Hardware Inst allation Not ice” will appear , please click “ Continue Anyway ” and the system ...

  • Lindy RS-422/485 - page 15

    (9) T o uninstall the driver: Please click S tart > Control Panel > Add or Remove P r o g r a m s C l i c k “ Change/Remove ” to uninstall the I/O driver . 7.2 Windows 2000 / XP / 2003 on a 64-bit system: On booting up, Windows 2000 / XP / 2003 will detect the presence of the PCI Serial card and will prompt for driver installation. Insert ...

  • Lindy RS-422/485 - page 16

    7.5 Dos: Please install the driv er from the CD ROM: PCI IODOSinst all.exe , and follow the installation step s from the CD ROM: PCI IOserial.p df 7.6 Windows 95 / 98SE / ME: On booting up, Windows 95 / 98SE / ME will detect the presence of the PCI Serial card and will prompt for driver installation. Insert the driver CD in your CD/DVD ROM dri ...

  • Lindy RS-422/485 - page 17

    (2) Select “Search for the best driv er for your device (Recommended)” and click “Next” to continue. (3) Please select “ Specify a location ” and point to the CD Dr iver directory to install the driver . : PCI IOwin9x - 15 - ...

  • Lindy RS-422/485 - page 18

    (4) The system will search and inst all t he appropriate IO driver automatically . Please click “ Next ” to continue. (5) Please click “ Finish ” to complete this installation step. Note: The “Add New Hardware Wizard” window s will display and install drivers several times until you finish setting up each serial port. 7.7 V erifying Ser ...

  • Lindy RS-422/485 - page 19

    When Windows has finished installing the driver you must check: Control Panel > System > Hardware > Device Manager >Port s[COM&LPT] It will show the additional ports: Note: 1. If you have installed PCI Serial port s in your system, you will be requested to restart your computer , when you have finished setting up each serial port. C ...

  • Lindy RS-422/485 - page 20

     8.0 Configure COM port (1) Select the PCI Serial Port which you want to configure, for example COM3 . Right click the mouse, and select “Properties” . (2) Click “ Port Settings ”. Configure the Bits per second, Dat a bits , Parity , S top bits and Flow control if you want to change them. There are three kinds of flow cont rol: Xon/Xoff, ...

  • Lindy RS-422/485 - page 21

    Click the “ Advanced ” button to set more advanced features. (3) Configure the “Enable Auto CTS/RTS Flow Control ”,“ 16/32 bytes FIFO length and Receive/T r ansmit Buffer trigger l evel if you want to change these settings (The 128K software FIFO adjustment only support s Microsof t Windows 2000 / XP / 2003 OS. Y ou can change the FI FO s ...

  • Lindy RS-422/485 - page 22

    - 20 - ...

  • Lindy RS-422/485 - page 23

    This device complies with Part 15 of the FCC Rules. Operation is subject to the followi ng two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. - 21 - ...

Производитель Lindy Категория Computer Hardware

Документы, которые мы получаем от производителя устройства Lindy RS-422/485 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Lindy
- инструкции обслуживания RS-422/485
- паспорта изделия Lindy
- информационные брошюры
- энергетические этикетки Lindy RS-422/485
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Lindy RS-422/485.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Lindy RS-422/485, инструкции обслуживания, короткие инструкции или инструкции пользователя Lindy RS-422/485. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Lindy RS-422/485.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Lindy RS-422/485, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Lindy RS-422/485 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Lindy RS-422/485.

Полная инструкция обслуживания Lindy, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Lindy RS-422/485 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Lindy RS-422/485, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Lindy RS-422/485, которое найдем в данном документе
3. Советы по использованию основных функций устройства Lindy RS-422/485 - которые должны облегчить нам первые шаги во время использования Lindy RS-422/485
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Lindy RS-422/485
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Lindy RS-422/485 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Lindy RS-422/485?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Lindy RS-422/485, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Lindy RS-422/485 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)