    Outdoor Knight Boiler User’s Information Manual Models: 151 - 286 If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance MUST NOT be installed in any location where gasoline or flammable vapors are likely to be present. WHAT TO DO IF YOU SM ...

  • Lochinvar 151 - page 2

    2 Hazard definitions The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or to important information concerning the life of the product.  DANGER  WARNING  CAUTION CAUTION NOTICE DANGER indicates an imminently hazardous situation which, if not avoided, will result ...

  • Lochinvar 151 - page 3

    Outdoor Knight Boiler User’s Information Manual Please read before proceeding The Outdoor Knight Boiler Installation and Operation Manual along with the Outdoor Knight Boiler Service Manual are for use only by a qualified heating installer/service technician. Refer only to this User’s Information Manual for your reference. Improper installation ...

  • Lochinvar 151 - page 4

    1 Prevent combustion air contamination 4 If the boiler combustion air inlet is located in a laundry room or pool facility, for example, these areas will always contain hazardous contaminants. To prevent the potential of severe personal injury or death, check for areas and products listed in Table 1 before installing the boiler or air inlet piping. ...

  • Lochinvar 151 - page 5

    2 Maintenance schedule 5 Service technician (see the Outdoor Knight Boiler Service Manual) General: • Reported problems • Inspect interior; clean and vacuum if necessary • Clean condensate trap and fill with fresh water • Check for leaks (water, gas, flue, condensate) • Verify flue and air lines in good condition and sealed tight • Chec ...

  • Lochinvar 151 - page 6

    2 Maintenance schedule 6 Maintenance procedures Boiler must be serviced and maintained  WARNING The boiler must be inspected and started annually at the beginning of the heating season by a qualified service technician. In addition, the maintenance and care of the boiler designated on page 5 of this manual and explained on pages 6 through 8 must ...

  • Lochinvar 151 - page 7

    2 Maintenance schedule (continued) 7 3. Fill with fresh water until the water begins to pour out of the drain. 4. Replace the cap. Press the cap onto the trap until the cap makes contact with the drain. 5. Replace the retaining screw.  WARNING The condensate trap (FIG. 1) must be filled with water during all times of boiler operation to avoid fl ...

  • Lochinvar 151 - page 8

    2 Maintenance schedule 8  WARNING Have leaks fixed at once by a qualified service technician. Failure to comply could result in severe personal injury, death, or substantial property damage. Operate relief valve 1. Before proceeding, verify that the relief valve outlet has been piped to a safe place of discharge, avoiding any possibility of scal ...

  • Lochinvar 151 - page 9

    9 3 Operating instructions o C Outdoor Knight Boiler User’s Information Manual ...

  • Lochinvar 151 - page 10

    Figure 4 Control Panel Outdoor Knight boiler control module Use the control panel (FIG. 4) to set temperatures, operating conditions, and monitor boiler operation. 4 SMART SYSTEM control module 10 The information on the bottom of the display shows the functions of the two SELECT keys (on either corner), and the NAVIGATION dial (in the center): MENU ...

  • Lochinvar 151 - page 11

    11 4 SMART SYSTEM control module (continued) Temperature Units The control can be configured to display temperature in either °F or °C. This parameter can be changed by the user or the installer by accessing the Temperature Units parameter . The default is °F. To change the temperature units, access the clock menu as described in the User sectio ...

  • Lochinvar 151 - page 12

    12 Status Display Screens Section Display Description A (Boiler Status Bar) STANDBY The unit has not received a call for heat from a remote thermostat nor has it received a call for heat from a DHW thermostat. START The unit has begun a burn cycle and is checking all safety circuits. PREPURGE The unit has initiated a prepurge period on a call for h ...

  • Lochinvar 151 - page 13

    4 SMART SYSTEM control module (continued) 13 Status Display Screens (cont’d) Section Display Description C (Operational Information) SYSTEM: The temperature read by the system supply sensor (if connected). TANK: The temperature read by the tank sensor (if connected). OUTDOOR: The temperature read by the outdoor sensor. INLET TEMP: The temperature ...

  • Lochinvar 151 - page 14

    14 4 SMART SYSTEM control module Status Display Screens (cont’d) Section Display Description D (LEFT SELECT key function) MENU Press and hold the LEFT SELECT key for 5 seconds to enter the Menu Screen. EXIT Press the LEFT SELECT key to exit the current screen or setting. YES Press the LEFT SELECT key to confirm that the boiler needs to shutdown. ...

  • Lochinvar 151 - page 15

    Notes 15 Outdoor Knight Boiler User’s Information Manual ...

  • Lochinvar 151 - page 16

    Revision Notes: Revision A (ECO C11234) initial release. OKB-USER Rev A 10/12 ...

Производитель Lochinvar Категория Boiler

Документы, которые мы получаем от производителя устройства Lochinvar 151 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Lochinvar
- инструкции обслуживания 151
- паспорта изделия Lochinvar
- информационные брошюры
- энергетические этикетки Lochinvar 151
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Lochinvar 151.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Lochinvar 151, инструкции обслуживания, короткие инструкции или инструкции пользователя Lochinvar 151. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Lochinvar 151.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Lochinvar 151, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Lochinvar 151 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Lochinvar 151.

Полная инструкция обслуживания Lochinvar, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Lochinvar 151 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Lochinvar 151, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Lochinvar 151, которое найдем в данном документе
3. Советы по использованию основных функций устройства Lochinvar 151 - которые должны облегчить нам первые шаги во время использования Lochinvar 151
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Lochinvar 151
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Lochinvar 151 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Lochinvar 151?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Lochinvar 151, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Lochinvar 151 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)