Инструкция обслуживания Mitsubishi Electronics PUHZ-RP250YHM-A

16 страниц 1.02 mb
Скачать

Перейти на страницу of 16

Summary
  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 1

    OUTDOOR UNIT PUHZ-RP250YHM-A For use with R410A INST ALLA TION MANU AL F or saf e and correct use, please read this installation manual thoroughly bef ore installing the air-conditioner unit. GB ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 2

    2 5 [Fig. 5.0.1] [Fig. 6.0.1] 6 (2) (1) (3) (4) [Fig. 5.0.2] <A> : T op view <B> : Side view <C> : When there is little space up to an obstruction A :F ront B : Unit height C :B a c k D : Air outlet guide (Procured at the site) A :F ront B : Must be open C :W all height (H) 15 * 15 * 450 * 300 * <A> A 100 * 450 * 50 * 50 * & ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 3

    3 7 [Fig. 7.1.1] 30mm A B C 8 8.2 [Fig. 8.2.1] A : Outdoor unit B : Indoor unit A B A 7.1 Å Outdoor model RP250 ı Liquid pipe ø9.52 Ç Gas pipe ø22.2 A 9.2 9 [Fig. 9.2.1] [Fig. 9.2.2] <A> Valve liquid side/ flared type A B C H I G F E D () <B> Valve gas side/ flanged type () [Fig. 9.2.3] A B [Fig. 9.2.4] A E D C B A : Close-packed p ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 4

    4 [Fig. 9.3.1] [Fig. 9.3.3] [Fig. 9.3.2] 9.3 A A : Nitrogen gas B :T o indoor unit C : System analyzer D : Low knob E : Hi knob F :V alve G : Liquid pipe H : Gas pipe I : Outdoor unit J : Service port A : System analyzer B : Low knob C : Hi knob D :V alve E : Liquid pipe F : Gas pipe G : Service port H : Three-way joint I :V alve J :V alve K : R410 ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 5

    5 [Fig. 10.4.1] A : Switch (Breakers f or wiring and current leakage) B : Breakers f or current leakage C : Outdoor unit BA C 3N~380–415V L 1 , L 2 , L 3, N PE C L1 L2 L3 N Terminal block for indoor – outdoor transmission line (TB3) Power supply terminal block (TB1) Control box A B [Fig. 10.2.1] 10.3 10.2 [Fig. 10.2.2] A B C [Fig. 10.3.1] 10 A ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 6

    6 D F E I NL P GR RU TR CZ SV SL HG PO GB Contents 1. Safety precautions 1.1. Bef ore installation and electric work s Before installing the unit, make sure y ou read all the “Safety precautions”. s The “Safety precautions” provide very important points re- garding safety . Make sure y ou follo w them. Symbols used in the text W arning: Des ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 7

    7 D F E I NL P GR RU TR CZ SV SL HG PO GB 1.4. Before installation (relocation) - electri- cal work Caution: • Ground the unit. - Do not connect the ground wire to gas or water pipes, lightning rods, or telephone ground lines. Improper grounding may result in electric shock. • Install the power cable so that tension is not applied to the cable. ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 8

    8 D F E I NL P GR RU TR CZ SV SL HG PO GB 7. Installation of unit 7.1. Installation [Fig. 7.1.1] (P .3) A M10 anchor bolt procured at the site. B Cor ner is not seated. C Fixing brack et for the hole-in anchor bolt (3 locations to fix with scre ws). • Fix unit tightly with bolts so that unit will not f all down due to earthquakes or strong winds. ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 9

    9 D F E I NL P GR RU TR CZ SV SL HG PO GB 8. Refrigerant piping installation The pipe is connected via a terminal-branch type connection in which refrigerant piping from the outdoor unit is branched at the terminal and is connected to each of the indoor units. The method of pipe connection is as follows: flare connection for the indoor units, gas p ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 10

    10 D F E I NL P GR RU TR CZ SV SL HG PO GB At the time of shipping, the outdoor unit is charged with refrigerant. This charge does not include the amount needed for e xtended piping and addi- tional charging of each refrigerant line will be required on site. In order that future servicing may be properly provided, alwa ys keep a record of the siz e ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 11

    11 D F E I NL P GR RU TR CZ SV SL HG PO GB Caution: Only use refrigerant R410A. - The use of other refrigerants such as R22 or R407C, which contains chlorine, will deteriorate the refrigerating machine oil or cause the compressor to malfunc- tion. 2 Evacuation Evacuate with the valve of the outdoor unit closed and evacuate both the con- nection pip ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 12

    12 D F E I NL P GR RU TR CZ SV SL HG PO GB 1. Use dedicated power supplies f or the outdoor unit and indoor unit. 2. Bear in mind ambient conditions (ambient temperature,direct sunlight, rain water ,etc.) when proceeding with the wiring and co nnections. 3. The wire size is the minimum v alue for metal conduit wiring. If the v oltage drops, use a w ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 13

    13 D F E I NL P GR RU TR CZ SV SL HG PO GB 11. T est run 11.1. The f ollowing phenomena do not represent faults. Display of remote controller Normal display Defrost display No lighting Heat ready “H0” or “PLEASE W AIT” flashes Normal display Normal display Normal display Cause Ultra-low speed operation is commenced at thermostat OFF . Light ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 14

    GB E F I NL E P GR RU TR ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 15

    GB E F NL E P GR RU TR ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 16

    WT05737X01 Printed in Japan HEAD OFFICE: T OKY O BLDG., 2-7-3, MARUNOUCHI, CHIY OD A-KU , T OKY O 100-8310, JAP AN Please be sure to put the contact address/telephone number on this manual before handing it to the customer. This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at ...

Производитель Mitsubishi Electronics Категория Air Conditioner

Документы, которые мы получаем от производителя устройства Mitsubishi Electronics PUHZ-RP250YHM-A мы можем разделить на несколько групп. Это в частности:
- технические чертежи Mitsubishi Electronics
- инструкции обслуживания PUHZ-RP250YHM-A
- паспорта изделия Mitsubishi Electronics
- информационные брошюры
- энергетические этикетки Mitsubishi Electronics PUHZ-RP250YHM-A
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Mitsubishi Electronics PUHZ-RP250YHM-A.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Mitsubishi Electronics PUHZ-RP250YHM-A, инструкции обслуживания, короткие инструкции или инструкции пользователя Mitsubishi Electronics PUHZ-RP250YHM-A. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Mitsubishi Electronics PUHZ-RP250YHM-A.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Mitsubishi Electronics PUHZ-RP250YHM-A, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Mitsubishi Electronics PUHZ-RP250YHM-A пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Mitsubishi Electronics PUHZ-RP250YHM-A.

Полная инструкция обслуживания Mitsubishi Electronics, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Mitsubishi Electronics PUHZ-RP250YHM-A - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Mitsubishi Electronics PUHZ-RP250YHM-A, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Mitsubishi Electronics PUHZ-RP250YHM-A, которое найдем в данном документе
3. Советы по использованию основных функций устройства Mitsubishi Electronics PUHZ-RP250YHM-A - которые должны облегчить нам первые шаги во время использования Mitsubishi Electronics PUHZ-RP250YHM-A
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Mitsubishi Electronics PUHZ-RP250YHM-A
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Mitsubishi Electronics PUHZ-RP250YHM-A в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Mitsubishi Electronics PUHZ-RP250YHM-A?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Mitsubishi Electronics PUHZ-RP250YHM-A, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Mitsubishi Electronics PUHZ-RP250YHM-A со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)