    SecureS t ack C2 Redundant Power Supply Chassis C2RPS-CHAS2 Inst allation Guide C2RPS-CHAS2 Caution: Do not use this product with SecureS tack PoE devices. Any SecureS tack device with a “P” suf f ix in the model number (C2xxxx-xxP) indicates a SecureS tack PoE-compliant device and is not compatible with this power system Precaución: El RPS no ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 2

    ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 3

    i Notice Enterasys Networks  reserv es  the  right  to  make  changes  in  specifica tions  and  other  information  containe d  in  this  document  and  its  web  site  without  prior  notice.  The  reader  should  in  all  cases  consult  Enterasys Netw orks ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 4

    ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This  device  co mplies  with  Pa r t  15  of  the  FCC  rules.  Operation  is  subjec t  to  the  following  two  conditions:  (1)  this  device  may  not  cause  harmfu l  interference,  ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 5

    iii Electromagnetic Compatibility (EMC) This  product  complies  with  the  following:  47  CF R  Pa r t s  2  and  15,  CSA  C108.8,  89/336/EEC,  EN  55022,  EN  61000 ‐ 3 ‐ 2,  EN 61000 ‐ 3 ‐ 3,  EN  55024,  AS/NZS  CISPR  22,  VCCI  V ‐ 3.  Compatibilidad ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 6

    iv Declaration of Conformity Application  of  Co uncil  Directiv e(s): 89/336/EEC 73/23/EEC Manufacturer’s  Na me: Enterasys Networks, Inc. Manufacturer ’ s  Address : 50  Minuteman  Road Andover,  MA  01810 USA European  Representativ e  Address: Enterasys Networks,  Ltd. Nexus  House,  Newbury  Bus ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 7

    v Enterasys Networks, Inc. Firmware License Agreement BEFORE  OPENING  OR  UTILIZING  THE  ENCLOSED  PRODUCT , CAREFULL Y  READ  THIS  LICENSE  AGREEMENT . This  document  is  an  agreement  (“ Agreement”)  between  the  end  user  (“Y ou”)  and  Enterasys Networks, Inc.  ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 8

    vi 3. APPLICABLE  LAW. This  Agreem ent  shal l  be  interpreted  and  governed  under  the  laws  and  in  the  state  and  federal  cour ts  of  the  Commonwealth  of  Massachusetts  wi thou t  regard  to  its  conflicts  of  laws  provisions.  You  ac ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 9

    vii 8. AUDIT  RIGHTS. You  here by  acknowl edge  that  the  intellectual  property  rights  associated  with  the  Program  are  of  critical  value  to  Enterasys  and,  accordingly,  You  hereby  agree  to maintain  complete  books,  records  and  accounts  ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 10

    viii ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 11

    ix Contents About This Guide Who Should Use This G uide .............. ................. ............ ............. ............. ................ ............. ... ........... xi How to Use This G uide ............. ................ ............. ............. ............. ............. ................ ........ ........... .... xi Related Docume ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 12

    x Tables 2-1 Contents of C2RPS-CHAS2 Carton . ............. ................ ............. ................ ............. ............... 2-2 2-2 Contents of C2RPS-PSM Carton ..................... ............. ................ ............. ............. ............. .. 2-2 A-1 C2RPS-CHAS2 Specifications ...... ............. ............. ....... ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 13

    SecureStack C2 Installation Guide xi About This Guide This  guide  provide s  an  overview ,  insta llation  and  troubleshooting  instructions,  and  specifications  for  the  Enterasys  Netw orks™  SecureStack  C2  redundant  pow er  supply  chassis  (C2RPS ‐ CHAS2),  pow er ? ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 14

    Related Documents xii About This Guide This  preface  provides  an  ov erview  of  this  guide  and  the  SecureStack  C2  manual  set,  and  a  brief  summary  of  each  chapter ,  and  the  conventions  used  throughout  this  guide.  To  locate  information ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 15

    Conventions Used in This Guide SecureStack C2 Installation Guide xiii Conventions Used in This Guide The  following  conventions  are  used  in  this  guide: Note: Calls the reader ’s attention to any item of information that may be of special import ance. Caution: Contains information essential to avoid damage to the equipme ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 16

    Conventions Used in This Guid e xiv About This Guide ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 17

    SecureStack C 2 Installation Gui de 1-1 1 Introduction This  chapter  provides  a  functional  overview  of  a  Re dundant  Po w e r  System  (R PS). RPS  Overview An  RPS  (redundant  power  system)  consisting  of  a  C2R PS ‐ CHAS2  chassis  and  C2RPS ‐ PSM  power  s ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 18

    C2RPS-CHAS2 Chassis 1-2 Introduction C2RPS-CHAS2 Chassis The  chassis  is  a  tw o ‐ sl ot  frame  without  AC  power  connections  or  electronics.  The  chassis  can  be  installed  in  a  standard  19 ‐ inch  rack  and  populated  with  one  or  tw o  PSMs. ? ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 19

    C2RPS-PSM Power Supply Module SecureStack C 2 Installation Gui de 1-3 C2RPS-PSM Power Supply Module The  C2RPS ‐ PSM  provides  the  following: •H o t  sw ap  capability .  •O n e  12  Vdc,  150  Wa t t s  of  maximum ‐ continuous  pow er  output  to  a  connected  SecureStack  C2 ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 20

    RPS Deployment Strategies 1-4 Introduction RPS Deployment S trategies The  RPS  can  be  de ployed  in  a  va r i e ty  of  situations  with  missi on ‐ critical  applications.  For example: •F o r  use  in  a  voice  and  data  netw ork  where  switches  are  connected  ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 21

    Getting Help SecureStack C 2 Installation Gui de 1-5 Getting Help For  additional  support  related  to  the  C2RPS ‐ CHAS2  or  this  document,  contact  Enterasys  Networks  us ing  one  of  the  following  methods: Before  contacti ng  Enterasys  Networks  for  technical  ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 22

    Getting Help 1-6 Introduction ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 23

    SecureStack C 2 Installation Gui de 2-1 2 Installation This  chapter  provides  instructions  to  install  all  the  components  of  an  RPS. To  correctly  install  an  RPS,  follow  the  order  of  information  listed  below . Required T ools A  flat ‐ blade  screwdriv er ? ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 24

    Installing C2RPS-PSMs 2-2 Installation 3. P erform  a  visual  inspection  of  the  switch  device s  for  any  signs  of  physical  damage.  Contact  Enterasys  Netw orks  if  there  are  any  signs  of  damage .  Refer  to  “ Getting  Help ”  on  page 1 ‐ ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 25

    Installing C2RPS-PSMs SecureStack C 2 Installation Gui de 2-3 Figure 2-1 C2RPS- PSM Inst allation Replacing an Inst alled C2RPS-PSM To  replace  a  PSM  installed  in  an  operating  syst em,  proceed  as  follows: 1. Unplug  the  AC  po wer  cord  of  the  PSM  from  the  AC  pow er ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 26

    Installing C2RPS-CHAS2 into the Rack 2-4 Installation To  install  a  PSM,  proceed  as  follows: 1. Align  the  PSM  with  the  slot,  then  slide  the  PSM  forward  until  its  front  panel  is  flush  against  the  chassis  front  panel.  2. Fasten  the  P ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 27

    Installing C2RPS-CHAS2 into the Rack SecureStack C 2 Installation Gui de 2-5 Rack Mounting the Chassis Refer  to  Figure 2 ‐ 2  and  proceed  as  follows  to  inst all  the  chassis  into  a  19 ‐ inch  (48.3 ‐ cm)  rack: 1. P osition  the  chassis  betw een  the  ve rt i ca l  fr ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 28

    Connecting the PSM Cables and AC Power Cords 2-6 Installation Connecting the PSM Cables and AC  Power Cords The  PS Ms  are  connected  to  the  SecureStack  C2  Ethernet  swi tch  device s  using  C2RPS ‐ PSM  Cables.  To  connect  the  PSMs,  pr oceed  as  follows: 1. Connect  on ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 29

    Connecting the PSM Cables and AC Power Cords SecureStack C 2 Installation Gui de 2-7 Figure 2-5 C2RPS-PSM Cable and AC Power Co rd Connections 5. On  certain  switches,  an  LED  indicator  will  show  that  a  redundant  pow er  supply  is  now  in  operation. . This  completes  the  install ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 30

    Connecting the PSM Cables and AC Power Cords 2-8 Installation ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 31

    SecureStack C2 Installation Guide A -1 A Specifications This  appendix  includes  specifications  for  the  C2RPS ‐ CHAS2,  C2RPS ‐ PS M,  12 ‐ Vdc  pow er  supply  output  connector ,  and  provides  the  Compliance  Standa rds. Enterasys  Netw orks  reserves  the  right  to ? ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 32

    C2RPS-PSM Specifications A-2 Specifications C2RPS-PSM Specifications Refer  to  Ta b l e A ‐ 2  for  the  input/outpu t  port  specifications. C2RPS-PSM Redundant Power Supply Output Connector For  pin  location  and  function,  refer  to  Figu re A ‐ 1  and  Ta b l e A ‐ 3 ,  respectively . ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 33

    Compliance Standards SecureStack C2 Installation Guide A -3 Compliance S t andards The  C2RPS ‐ PSM  meets  the  safety  and  electromagnetic  compati bility  (EMC)  requirements  listed  in  Ta b l e A ‐ 4 : T able A-3 C2RPS-PSM Redundant Power Supply Connector Pin Fu nctions Pin Number Function 1 Ground 2 N ...

  • Enterasys SecureStack C2RPS-CHAS2 - page 34

    Compliance Standards A-4 Specifications ...

Производитель Enterasys Категория Power Supply

Документы, которые мы получаем от производителя устройства Enterasys SecureStack C2RPS-CHAS2 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Enterasys
- инструкции обслуживания SecureStack C2RPS-CHAS2
- паспорта изделия Enterasys
- информационные брошюры
- энергетические этикетки Enterasys SecureStack C2RPS-CHAS2
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Enterasys SecureStack C2RPS-CHAS2.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Enterasys SecureStack C2RPS-CHAS2, инструкции обслуживания, короткие инструкции или инструкции пользователя Enterasys SecureStack C2RPS-CHAS2. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Enterasys SecureStack C2RPS-CHAS2.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Enterasys SecureStack C2RPS-CHAS2, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Enterasys SecureStack C2RPS-CHAS2 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Enterasys SecureStack C2RPS-CHAS2.

Полная инструкция обслуживания Enterasys, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Enterasys SecureStack C2RPS-CHAS2 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Enterasys SecureStack C2RPS-CHAS2, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Enterasys SecureStack C2RPS-CHAS2, которое найдем в данном документе
3. Советы по использованию основных функций устройства Enterasys SecureStack C2RPS-CHAS2 - которые должны облегчить нам первые шаги во время использования Enterasys SecureStack C2RPS-CHAS2
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Enterasys SecureStack C2RPS-CHAS2
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Enterasys SecureStack C2RPS-CHAS2 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Enterasys SecureStack C2RPS-CHAS2?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Enterasys SecureStack C2RPS-CHAS2, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Enterasys SecureStack C2RPS-CHAS2 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)