    990-2975 09/2 006 APC Smar t-UPS ® XL 2200/3000 V A XL 120/208/230 V AC T ower/Rack-Mount 5U Uninter r uptible P ower Supply User Manual English ...

  • American Power Conversion 208 VAC - page 2

    ...

  • American Power Conversion 208 VAC - page 3

    Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Ra ck-Mount 5U User Manual 3 Introduction About this UPS The American Power Conversion (APC®) Uninterrupt ible Power Supply (UPS) provides protectio n for electronic equipment from utility power blackouts, brow nouts, sags and surges. The UPS filters small utility line fluctuations and isolates elect ...

  • American Power Conversion 208 VAC - page 4

    4 Smart-UPS 2200/30 00 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual Inst allation The UPS is shipped in t ower configuration. T ower Configuration Connect the battery . After the battery has been connected, tuck the battery cables in between the battery and the battery door . This will ensure a s ecure fit of the bezel to the unit. ...

  • American Power Conversion 208 VAC - page 5

    Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Ra ck-Mount 5U User Manual 5 Rack-Mount Configuration This unit is intended for mounti ng in a two post rack. T o order a four post rack-mount kit contact you r dealer or refer to the APC W eb site, www .apc.com. T ower to rack-mount conversion pr ocedure The UPS and the battery modules are heavy . Re ...

  • American Power Conversion 208 VAC - page 6

    6 Smart-UPS 2200/30 00 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual Install unit in rack Ensure rack stability prior to installing devices in the rack. The UPS should be install ed at or near the bottom of the r ack. If external battery packs are to be installed in the rack, the UPS must be the to p unit in the conf iguration. Accessories ...

  • American Power Conversion 208 VAC - page 7

    Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Ra ck-Mount 5U User Manual 7 Star t- U p Connect Equipment and Power to the UPS 1. The UPS features a transient voltage surge-suppression ( TVSS ) screw located on the rear panel, for connecting the gro und lead on surge suppression devi ces such as telephone and network line protectors. Prior to conn ...

  • American Power Conversion 208 VAC - page 8

    8 Smart-UPS 2200/30 00 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual Communication Port s Emergency Power Off The emer gency power off (EPO) feature is user conf igurable. EPO provides immediate de-en ergizing of connected equipment from a remote location , without switching to battery operation. 1. Use the EPO connector supplied with the U ...

  • American Power Conversion 208 VAC - page 9

    Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Ra ck-Mount 5U User Manual 9 Operation Display Panels Display Panel Indicators and Function Buttons Indicator LED Indicator Title Description On Line The UPS is supplying utility power to the connected equipment, (see T r oubleshooting ). A VR T rim The UPS is compensating f or a high utility voltage. ...

  • American Power Conversion 208 VAC - page 10

    10 Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual Indicator LED Indicator Title Description Diagnostic Utility V oltage The UPS has a diagnostic feature th at indicates the utility voltage. The UPS starts a self-test as part of this procedure. The self -test does not affect the voltage display . Press and hold the button ...

  • American Power Conversion 208 VAC - page 11

    Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Ra ck-Mount 5U User Manual 11 Configuration UPS settings Settings are adjusted through PowerChute soft ware or optional SmartSlot accessory cards. Function Factory Default User Selectable Choices Description Automatic Self-T est On startup and every 14 days (336 hours) there after • On startup and e ...

  • American Power Conversion 208 VAC - page 12

    12 Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual Low Battery Wa r n i n g PowerChute software interface provides automatic, unattended shutdown when approximately two minutes of battery operated run time remains. 2 minutes LED is located on rear panel Brightly illuminated: low battery warnin g level of about 2 min utes D ...

  • American Power Conversion 208 VAC - page 13

    Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Ra ck-Mount 5U User Manual 13 T roubleshooting Use this chart to solve minor UPS installation and operati on problems. Refer to www .apc.com for assistance with complex UPS problems. Problem and/or Possible Cause Solution UPS will not turn on The battery is not connected properly . Check that the batt ...

  • American Power Conversion 208 VAC - page 14

    14 Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual The Overload LED is illuminated and the UPS emits a sustained alarm tone The UPS is overloaded. The connect ed equipment exceed s the specif ied “maximu m load” as defined in Specifications on the APC W eb site, www .apc.com. The alarm remains on until the overload is ...

  • American Power Conversion 208 VAC - page 15

    Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Ra ck-Mount 5U User Manual 15 There is no utili ty power There is no utility power and the UPS is off. Use the cold start feature to supply p o wer to the connected equipment front the UPS battery(s). Press and hold the button. There will be a short beep followed by a longer beep. Release the but ton ...

  • American Power Conversion 208 VAC - page 16

    16 Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual Maintenance, T ransport, and Service Replacing the Battery Module This UPS has easy-to-replace, hot-swa ppable battery modules. Replacement is a safe procedure, isolated from electrical hazards. Y ou may leave the UPS and connect ed equipment on during the replacement proc ...

  • American Power Conversion 208 VAC - page 17

    Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Ra ck-Mount 5U User Manual 17 T wo-Y ear W arranty The limited warranty provided by Amer ican Power Conversion (APC®) in this statement of Limited F actory W arranty applies only to products you purchase for yo ur commercial or indust rial use in the ordinar y course of your business. T e rms of warr ...

  • American Power Conversion 208 VAC - page 18

    18 Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual Regulatory Information Regulatory Agency Approvals an d Radio Frequency W arnings FCC Compliance Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to par t 15 of the FCC Rules. These limits are designed to prov ...

  • American Power Conversion 208 VAC - page 19

    Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Ra ck-Mount 5U User Manual 19 Date of p roduct declaration ...

Производитель American Power Conversion Категория Power Supply

Документы, которые мы получаем от производителя устройства American Power Conversion 208 VAC мы можем разделить на несколько групп. Это в частности:
- технические чертежи American Power Conversion
- инструкции обслуживания 208 VAC
- паспорта изделия American Power Conversion
- информационные брошюры
- энергетические этикетки American Power Conversion 208 VAC
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания American Power Conversion 208 VAC.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа American Power Conversion 208 VAC, инструкции обслуживания, короткие инструкции или инструкции пользователя American Power Conversion 208 VAC. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия American Power Conversion 208 VAC.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства American Power Conversion 208 VAC, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании American Power Conversion 208 VAC пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей American Power Conversion 208 VAC.

Полная инструкция обслуживания American Power Conversion, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией American Power Conversion 208 VAC - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания American Power Conversion 208 VAC, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся American Power Conversion 208 VAC, которое найдем в данном документе
3. Советы по использованию основных функций устройства American Power Conversion 208 VAC - которые должны облегчить нам первые шаги во время использования American Power Conversion 208 VAC
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем American Power Conversion 208 VAC
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра American Power Conversion 208 VAC в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся American Power Conversion 208 VAC?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с American Power Conversion 208 VAC, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с American Power Conversion 208 VAC со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)