  • Vector DK080706 - page 1

    1 OWNER’S MANUAL & W ARRANTY INFORMA TION THI S MA NUA L CON T AIN S IM POR T A NT IN FOR MA TI ON R EGA RDI NG SA FET Y , OPER A TIO N, MAINTENANCE AND STORAGE OF THIS PRODUCT . BEFORE USE, READ AND UND ERS T AND ALL CA UTI ONS , W AR NIN GS, INST RUC TIO NS AN D PRO DUC T LAB ELS, PLU S YOUR VEHICLE’S BA TTERY MANUF ACTURER GUIDELINES. F ...

  • Vector DK080706 - page 2

    2 IMPOR T ANT SAFETY INSTRUCTIONS Read and Understand all W arnings, Cautions and Notes before operating Power City . W arnings alert the user to hazardous conditions that can be harmful to people. Cautions aler t the user to conditions that can cause property damage. Notes are impor tant operational information. KEEP THIS USER’S GUIDE FOR FUTURE ...

  • Vector DK080706 - page 3

    3 CONTENTS 1. INTRODUCTION ...................................................... 4 1.1 General discription .............................................................................. 4 1.2 Key features ........................................................................................ 5 1.3 Use Power City to ............................... ...

  • Vector DK080706 - page 4

    4 1. INTRODUCTION Congratulations on selecting the V ector Power City® Multi-Function AC/DC Power Sys- tem. Power City is an advanced power and jump-star t system with unique features that set it far above the value and utility of ordinar y jump-star ters. It supplies AC for 120 volt appliances to 200 watts, and DC for 12 volt appliances to 23 amp ...

  • Vector DK080706 - page 5

    5 FIGURE 2 1.2 KEY FEA TURES • On/of f safety power switch (no key required, no key to get lost!) • Cordless/rechargeable-includes recharge adapters for standard 120 volt AC wall socket and vehicle’ s 12 volt DC accessor y outlet using adapter cables • Power ful 400 boost amps; 1200 peak amps • Includes non-spillable, maintenance-free, he ...

  • Vector DK080706 - page 6

    6 1. TIRE V AL VE CONNECTOR 2. COMPRESSOR HOSE 3. AC/DC CHARGER 4. INVERTER POWER CORD, LANTERN EXTENSION CORD 5. CABLE & NOZZLES STORAGE COMP ARTMENT 6. DC RECHARGE POWER CORD 7. CABLE STORAGE CHANNEL 8. NEGA TIVE JUMPER CABLE 9. POSITIVE JUMPER CABLE 10. COMPRESSOR HOSE STORAGE CHANNEL 11. RETRACT ABLE HANDLE 12. 3 COMPRESSOR HOSE ADAPTERS 6 ...

  • Vector DK080706 - page 7

    7 3. USE AS A 12 VOL T DC PORT ABLE POWER SUPPL Y W ARNING: NEVER INSERT A CIGARETTE LIGHTER IN POWER CITY’S ACCESSORY SOCK- ET . 1. Lift up the cover of one of the12 volt DC accessor y sockets. 2. Insert the 12 volt DC plug from the appliance into the accessor y socket. 3. Switch on the appliance, as usual. 4. Periodically press the batter y sta ...

  • Vector DK080706 - page 8

    8 4.2 PRINCIPLES OF OPERA TION The power inverter conver ts power in two stages. The first stage is a DC-to-DC conversion process that raises the low voltage DC at the inver ter input to 145 volts DC. The second stage is the actual inverter stage that converts the high voltage DC into 120 volts, 60 Hz AC, Modi- fied Sine W ave (MSW). MSW is a wav ...

  • Vector DK080706 - page 9

    9 FIGURE 6 FIGURE 7 4.3.1 PROCEDURE FOR CONNECTING INVERTER TO REMOTE DC SOURCE Open the cable hatch and remove the Inver ter power cable (the one with the lantern extension cord) press the inverter cover tab and remove the cover . Ensure that the inverter’ s power switch is off. Then press the two tabs that lock in the Inverter and release the I ...

  • Vector DK080706 - page 10

    10 DO NOT CONNECT TO AC DISTRIBUTION WIRING: the inver ter is engineered to be connected directly to sta ndard electrical and electronic equipme nt in th e manner described above. Do not direct wire the power inverter to household or RV AC distribution wiring. Do not connect the power inverter to any AC load circuit in which the neutral conductor i ...

  • Vector DK080706 - page 11

    11 4.7 INVERTER FUSE REPLACEMENT The following assumes that the main unit batter y has a charge and that there is no output from the 120 V AC receptacle. If you find that a fuse is blown (open) determine the cause of the shor t before restarting the power inverter again. Fuse replacement in automobile: Most automobile 12 volt DC accessor y outlet ...

  • Vector DK080706 - page 12

    12 5.3 TIRE INFLA TION OR PRODUCTS WITH A V AL VE STEM 1. Place connector (chuck) on valve stem. 2. Push connector toward valve stem and close thumb latch. 3. Make sure connector is pushed on to valve stem as far as possible before closing thumb latch. 4. Check pressure with the pressure gauge. (Refer to paragraph 5.5) 5. When desired pressure is r ...

  • Vector DK080706 - page 13

    13 6.2 LANTERN OPERA TION DET A TCHED FROM MAIN UNIT The lanter n may be removed for use away from the main unit by first sliding the top latch back and then lifting the Lantern. as shown in Figure 8. FIGURE 8 A barrel connector near the spring contacts on the back of the Lanter n accepts either the AC recharge or DC inverter power cable’ s lant ...

  • Vector DK080706 - page 14

    14 LANTERN LENS LENS RET AINING SCREW FLUORES- CENT LAMP SPRING CLIP BOTTOM LENS T AB 6.3 LAMP REPLACEMENT The only lamp is in the lantern assembly . For any maintenance of the lamp, you will need a small Phillips screwdriver and a soft clean cloth. Replacement bulbs are available from V ector T echni - cal Support Department call toll-free 866-584 ...

  • Vector DK080706 - page 15

    15 7.1 AC RECHARGE AC recharge requires the use of the supplied AC/DC adapter . The adapter must be powered from 120 volt AC, 60 Hz Nor th American standard household AC outlets. The batter y status display will automatically activate during AC recharge. As recharge progresses, the red LEDs will light one by one. Charge the Power City until the bat ...

  • Vector DK080706 - page 16

    16 5. Charge the unit until the green CHARGED indicator is lit when the charge status button is pressed - DO NOT EXCEED 8 HOURS MAXIMUM. 6. After charging, disconnect the cables and store them in the cable storage hatch. 7.3 AL TERNA TE DC RECHARGE If the Inverter is removed from the main unit, the DC recharge cable can be directly connected to the ...

  • Vector DK080706 - page 17

    17 10. SPECIFICA TIONS: Jump Start Clamps ...................................................... 400 Amps - Heavy Duty Copper Jumper Cables ........................................................................ #4A WG W elding Cable Peak Amps ......................................................................................................... ...

  • Vector DK080706 - page 18

    18 ONE YEAR LIMITED W ARRANTY PROGRAM This limited warranty program is the only one that applies to this product, and it sets forth all the responsibilities of V ector Products, Inc., regarding this product. There is no other warranty , other than those described herein. This V ector Products, Inc. product is warranted, to the original purchaser on ...

  • Vector DK080706 - page 19

    19 ...

  • Vector DK080706 - page 20

    20 © 2006 VECTOR PRODUCTS, INC. FT . LAUDERDALE, FL 33312 MADE IN CHINA DK080706 ...

Производитель Vector Категория Automobile Parts

Документы, которые мы получаем от производителя устройства Vector DK080706 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Vector
- инструкции обслуживания DK080706
- паспорта изделия Vector
- информационные брошюры
- энергетические этикетки Vector DK080706
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Vector DK080706.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Vector DK080706, инструкции обслуживания, короткие инструкции или инструкции пользователя Vector DK080706. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Vector DK080706.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Vector DK080706, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Vector DK080706 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Vector DK080706.

Полная инструкция обслуживания Vector, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Vector DK080706 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Vector DK080706, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Vector DK080706, которое найдем в данном документе
3. Советы по использованию основных функций устройства Vector DK080706 - которые должны облегчить нам первые шаги во время использования Vector DK080706
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Vector DK080706
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Vector DK080706 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Vector DK080706?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Vector DK080706, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Vector DK080706 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)