    All information contained herein is subject to change without notice. I NST ALLA TION I NSTRUCTIONS F OR L IGHT C OMMERCIAL S ELF -C ONT AINED P ACKAGED H EA TING & C OOLING U NIT 3 T ON - 6 T ON CPC/CPH S ERIES Goodman Manufacturing Company , L.P . IO-399A 5151 Felipe, Suite 500, Houston, TX 77056 5/12 www .goodmanmfg.com www .amana-hac.com © ...

  • Goodman Mfg CPC/CPH - page 2

    2 REPLACEMENT PARTS O RDERING P ARTS When reporting shortages or damages, or ordering rep air part s, give the complete unit model and serial numbers as stamped on the unit’ s nameplate. Replacement parts for this appliance are available through your contractor or local distributor . For the location of your nearest distributor , consult the whit ...

  • Goodman Mfg CPC/CPH - page 3

    3 T HIS UNIT MU ST NOT BE USED AS A “ CONST RUC TION HEATE R ” DURING THE FINISHING PHAS ES OF CONST RUC TION ON A NEW STRUCT UR E . T HIS TYPE OF USE MA Y RESU LT IN PREMAT UR E FAILURE OF THE UNIT DUE TO EXT REME LY LOW RETURN AIR TEMP ERAT URES AND EXPO SURE TO CORR OSIVE OR VER Y DIRT Y ATMO SPHE RES . W ARNING HI GH VO L T A GE ! D ISCO NN ...

  • Goodman Mfg CPC/CPH - page 4

    4 NOTE: When inspecting the unit for transportation damage, remove all packaging materials. Recycle or dispose of the packaging material according to local codes. P RE -I NSTALLATION C HECKS Carefully read all instructions for the installation prior to in- stalling unit. Ensure each step or procedure is understood and any special considerations are ...

  • Goodman Mfg CPC/CPH - page 5

    5 Full perimeter roof curbs are available from the factory and are shipped unassembled. Field assembly , squaring, level- ing and mounting on the roof structure are the responsibility of the installing contractor . All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory . T O PRE VENT PO SSIBLE EQ ...

  • Goodman Mfg CPC/CPH - page 6

    6 P ROTRUSION Inspect curb to ensure that none of the utility services (elec- tric) routed through the curb protrude above the curb. I F PROT RUSIO NS EXI ST , DO NO ATTEMPT TO SET UNIT ON CURB . CAUTION ROOF TOP DUCT CONNECTIONS Install all duct connections on the unit before placing the unit on rooftop. H ORIZONTAL D ISCHARGE For horizontal disch ...

  • Goodman Mfg CPC/CPH - page 7

    7 Lower unit carefully onto roof mounting curb. While rigging unit, center of gravity will cause condenser end to be lower than supply air end. T o assist in determining rigging requirements, unit weights are shown as follows: A B C D CG SUPP LY RETURN EV APORA TOR COIL CONDENSER COIL COMPRESSOR Y X CORNER & CENTER OF GRAVITY LOCATIONS AB CD CP ...

  • Goodman Mfg CPC/CPH - page 8

    8 T O PRE VENT SEVE RE DAMAG E TO THE BOTTOM OF THE UNIT , DO NOT FORK LIFT UNIT AFTER WOOD STRUT S HAVE BEEN REMOV ED . CAUTION Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a r ...

  • Goodman Mfg CPC/CPH - page 9

    9 LOW VOLT AGE BLOCK MA IN PO WER LOW VO L T AGE ENTRANCE POWER THRU THE CURB CONTROL BOX F AILU RE OF UNIT DUE TO OPERATION ON IMP ROPER LINE VOLTAGE OR WITH EXC ESSI VE PHAS E UNBAL ANC E CONSTITUTES PRODUCT ABUSE AND WILL VO I D YO U R WARRANT Y AND MA Y CAUSE SEVE RE DAMAG E TO THE UNIT ELECTR ICAL COMPONE NTS . W ARN I NG Areas Without Conveni ...

  • Goodman Mfg CPC/CPH - page 10

    10 CIRCULA TING AIR AND FIL TERS D UCTWORK The supply duct from the unit through a wall may be installed without clearance. However , minimum unit clearances must be maintained (see “Clearances” section). The supply duct should be provided with an access panel large enough to inspect the air chamber downstream of the heat exchanger . A cover sh ...

  • Goodman Mfg CPC/CPH - page 11

    11 T OOLS R EQUIRED Refrigeration gauge and manifold V oltmeter Clamp-on ammeter Ohmmeter T est lead (Minimum #16 A WG with insulated alligator clips) Air temperature measuring device General refrigeration mechanics’ tools T EMPORARY H EATING O R C OOLING If the unit is to be used for temporary heating or cooling, a “S tartup, Adjustments, and ...

  • Goodman Mfg CPC/CPH - page 12

    12 t = Span length, inches C = Center distance, inches D = Larger sheave diameter , inches d = Smaller sheave diameter , inches h = Deflection height, inches DRIVE BELT TENSION ADJUSTMENT BE L T DR IV E Use d Ne w A , A X Sta nda r d 3.0 to 4 .0 4. 2 ± .5 5. 5 ± . 5 0. 313 DE F L ECT I O N (in) DE F L ECT I O N FO RCE ( lbs) SH EA VE DIAM E T E R ...

  • Goodman Mfg CPC/CPH - page 13

    13 1 1. Slowly raise the heating temperature setting. When the heating first stage makes contact, stop raising the temperature setting.. The compressor , blower and fan should now be running with the reversing valve in the de-energized (heating) position. After giving the unit time to settle out, make sure the unit is supplying heated air . 12. If ...

  • Goodman Mfg CPC/CPH - page 14

    14 E V A P O R A T O R COOLI NG SERV I C E VALVE SERVICE PO RT REVERSI NG VALVE C O N D E N S E R SERV I C E POR T COM PRES S OR SERV I C E POR T ACCUMULAT O R EXPANSION D EVI C E CH ECK VALVE ORI FI CE SERV I C E VALVE CHECK VA LVE ORIFI CE IN DO O R COI L DI ST RIBUTOR OUTD OOR CO I L E V A P O R A T O R HEAT I NG SERV I C E VALVE SERV I C E POR ...

  • Goodman Mfg CPC/CPH - page 15

    15 DRIVE ADJUSTMENTS MOTOR SHEA VE ADJUSTMENTS V L , V M , & 2 VP V ARIABLE P ITCH K EY T YPE M OTOR S HEAVES The driving and driven motor sheaves should be in align- ment with each other and the shaft s parallel. V L & V M S HEAVES A DJUSTMENT 1. Loosen set screw “B” using a 5/32" Allen key . 2. Making half or full turns from clos ...

  • Goodman Mfg CPC/CPH - page 16

    16 L UBRICATION The fan shaft bearings, the 1 to 2 HP supply fan motors the condenser fan motors and compressors are permanently lu- bricated. F UNCTIONAL P ARTS Refer to the unit Parts Catalog for a list of functional p arts. Parts are available from your distributor . SERVICE THE FOLLOWING INFORMA TION IS FOR USE BY QUALI- FIED SERVICE AGENCY ONL ...

  • Goodman Mfg CPC/CPH - page 17

    17 APPENDIX A BLOWER PERFORMANCE TABLES DIRECT DRIVE ST ANDARD DOWN SHOT AND HORIZONT AL SPE ED T A P E XTE RNAL S T AT IC PR E SS UR E ( ESP ) in w . c . S T A N DARD CFM A M PS WA T TS R PM 0. 10 1287 1 .66 3 50 770 0. 20 1233 1 .63 3 42 815 0. 30 1176 1 .59 3 32 858 0. 40 1107 1 .55 3 20 891 0. 50 1044 1 .51 3 12 924 0. 60 965 1 .45 2 96 957 0. ...

  • Goodman Mfg CPC/CPH - page 18

    18 APPENDIX A BLOWER PERFORMANCE TABLES DIRECT DRIVE ST ANDARD DOWN SHOT AND HORIZONT AL SPE ED T A P E XTE RNAL S T AT IC PR E SS UR E ( ESP ) in w . c . S T A N DARD CFM A M PS WA T TS R PM 0. 10 1602 2 .48 5 28 835 0. 20 1538 2 .37 5 06 878 0. 30 1474 2 .26 4 84 921 0. 40 1390 2 .15 4 60 950 0. 50 1306 2 .04 4 36 979 0. 10 1805 2 .84 6 20 935 0. ...

  • Goodman Mfg CPC/CPH - page 19

    19 APPENDIX A BLOWER PERFORMANCE TABLES DIRECT DRIVE ST ANDARD CPC/H060 DOWN SHOT SP EED TAP E XTE RNAL S T ATIC PR E SSU R E ( ESP ) in w . c . S T ANDAR D CF M AM P S W ATTS R P M 0. 10 1 334 1.6 5 180 62 7 0. 20 1 286 1.7 5 192 66 5 0. 30 1 212 1.8 3 202 71 5 0. 40 1 144 1.9 4 216 75 9 0. 50 1 077 1.9 9 222 79 2 0. 60 1 039 2.1 0 238 83 0 0. 70 ...

  • Goodman Mfg CPC/CPH - page 20

    20 APPENDIX A BLOWER PERFORMANCE TABLES DIRECT DRIVE ST ANDARD CPC/H060 HORIZONT AL SP EED TAP E XTE RNAL S T AT IC PR E SSU R E ( ESP ) in w . c . STANDAR D CF M AMP S W AT T S R PM 0. 10 1 355 1.57 174 59 9 0. 20 1 281 1.66 182 65 1 0. 30 1 235 1.76 196 69 3 0. 40 1 168 1.81 202 72 6 0. 50 1 118 1.94 218 77 5 0. 60 1 049 2.03 232 81 9 0. 70 9 82 ...

  • Goodman Mfg CPC/CPH - page 21

    21 APPENDIX A BLOWER PERFORMANCE TABLES BEL T DRIVE ST ANDARD DOWN SHOT CP C/H0 36 ST AND AR D BEL T DR I VE DO W N SHO T CFM BHP C FM BHP CFM BH P CF M B HP C F M BHP CFM BH P 0. 2 1 42 4 0. 3 0 1 2 39 0. 2 3 0. 4 152 0 0. 39 1 292 0.2 9 10 73 0 .22 77 9 0 .14 0. 6 14 39 0 .40 119 2 0. 30 9 44 0. 2 1 6 19 0 .1 2 0. 8 1 350 0. 4 2 11 01 0 . 31 86 4 ...

  • Goodman Mfg CPC/CPH - page 22

    22 APPENDIX A BLOWER PERFORMANCE TABLES BEL T DRIVE HIGH ST A TIC DOWN SHOT CP C/H036 HI G H S T ATI C BE L T DRI V E DOWN S HOT CFM BHP C FM BHP CFM BH P CF M B HP C F M BHP CFM BH P 0. 6 16 9 2 0 . 54 1 44 9 0. 4 1 1 1 73 0. 2 9 0. 8 167 8 0. 58 1 397 0.4 4 11 07 0 .3 1 85 4 0 .21 1. 0 16 81 0 . 65 138 1 0. 49 1 078 0. 3 4 7 94 0 .2 2 1. 2 1 681 ...

  • Goodman Mfg CPC/CPH - page 23

    23 APPENDIX A BLOWER PERFORMANCE TABLES BEL T DRIVE ST ANDARD HORIZONT AL CP C/H036 STAND ARD BE L T DRI VE HORI Z O NT AL CFM BHP C FM BHP CF M BH P C FM B HP C FM BHP CFM BH P 0. 2 1 65 8 0. 3 5 1 4 89 0. 2 8 0. 4 1 560 0. 3 6 13 39 0 . 28 112 9 0 .21 0. 6 16 82 0 .47 143 6 0. 36 1 196 0.2 7 9 49 0 .19 0. 8 1 581 0.5 0 13 54 0 .38 109 6 0. 28 8 2 ...

  • Goodman Mfg CPC/CPH - page 24

    24 APPENDIX A BLOWER PERFORMANCE TABLES BEL T DRIVE HIGH ST A TIC HORIZONT AL CP C/H036 HI G H S T AT I C BE L T DRI VE HORIZO NT AL CFM BHP C FM BHP CFM BH P CF M B HP C F M BHP CFM BH P 0. 6 1 74 2 0. 5 0 1 4 31 0. 3 6 0. 8 16 2 6 0 . 52 1 35 7 0. 3 9 1 0 78 0. 2 7 1 161 1 0. 56 1 31 5 0.4 2 10 11 0 . 28 1. 2 16 05 0 . 62 129 9 0. 46 9 76 0. 3 1 ...

  • Goodman Mfg CPC/CPH - page 25

    25 APPENDIX B ELECTRICAL DA T A MIN. M AX . Q TY RLA LRA QTY H P R LA H P FLA 20 8 /2 3 0- 60 - 1 18 7 2 53 1 1 6. 6 7 7 9 1 1 / 4 1. 4 0 D D S T D S T A T I C 1 / 3 2. 5 DD S TD S TA T I C 1 / 3 2.5 BD ST D ST A T I C 1.0 3 .8 46 0- 60 -3 41 4 5 06 1 5 .7 7 3 8. 0 1 1 / 4 0. 8 0 BD ST D S T A T I C 1 . 0 1. 9 57 5- 60 -3 51 8 6 33 1 3. 8 3 7. 0 1 ...

  • Goodman Mfg CPC/CPH - page 26

    26 A TTENTION INST ALLING PERSONNEL Use only the heater kit specified for each model as dict ated by the table above. APPENDIX B ELECTRICAL DA T A UNIT HE AT ER KIT MO DE L NU M B ER MI N I MU M C F M EH K *-1 0 1 2 5 0 EH K *-1 5 1 2 5 0 EH K *-1 0 1 3 0 0 EH K *-1 5 1 4 0 0 EH K *-1 8 1 4 0 0 EH K *-1 0 1 7 0 0 EH K *-1 5 1 7 0 0 EH K *-2 0 1 8 0 ...

  • Goodman Mfg CPC/CPH - page 27

    27 APPENDIX C UNIT DIMENSIONS HORIZONTAL DISCHARGE VERTICAL DISCHARGE NOTE For horizontal discharge, remove the supply and return duct covers and place them over the vertical discharge return and supply openings. Install with insulation facing up, using the longer screws provided in the literature package. RETURN SUPPL Y 12” 17” 7 3/ 8” 11 ? ...

  • Goodman Mfg CPC/CPH - page 28

    28 Goodman Manufacturing Company , L.P . 5151 Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com www .amana-hac.com © 2010,2012 Goodman Manufacturing Company , L.P . ...

Производитель Goodman Mfg Категория Air Conditioner

Документы, которые мы получаем от производителя устройства Goodman Mfg CPC/CPH мы можем разделить на несколько групп. Это в частности:
- технические чертежи Goodman Mfg
- инструкции обслуживания CPC/CPH
- паспорта изделия Goodman Mfg
- информационные брошюры
- энергетические этикетки Goodman Mfg CPC/CPH
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Goodman Mfg CPC/CPH.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Goodman Mfg CPC/CPH, инструкции обслуживания, короткие инструкции или инструкции пользователя Goodman Mfg CPC/CPH. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Goodman Mfg CPC/CPH.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Goodman Mfg CPC/CPH, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Goodman Mfg CPC/CPH пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Goodman Mfg CPC/CPH.

Полная инструкция обслуживания Goodman Mfg, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Goodman Mfg CPC/CPH - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Goodman Mfg CPC/CPH, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Goodman Mfg CPC/CPH, которое найдем в данном документе
3. Советы по использованию основных функций устройства Goodman Mfg CPC/CPH - которые должны облегчить нам первые шаги во время использования Goodman Mfg CPC/CPH
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Goodman Mfg CPC/CPH
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Goodman Mfg CPC/CPH в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Goodman Mfg CPC/CPH?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Goodman Mfg CPC/CPH, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Goodman Mfg CPC/CPH со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)