    Thank you for selecting Aiphone for your communication and security needs. Please read this manual carefully before installation, and keep it in a safe place for future reference. Also read the SETTING MANUAL and OPERA TION MANUAL on the bundled CD-ROM. When the installation is completed, con fi gure the system by following the SETTING MANUAL. Oth ...

  • Aiphone 834168 C P0811JZ - page 2

    2 CONTENTS PRECAUTIONS ................................ 3 W ARNING ....................................... 3 CAUTION ........................................ 3 GENERAL PRECAUTIONS ............ 3 Notes on using this system .......... 4 Notices ............................................ 4 SYSTEM CONFIGURA TIONS .......... 4 Entire system .......... ...

  • Aiphone 834168 C P0811JZ - page 3

    3 PRECAUTIONS General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to W ater General Precautions W ARNING Negligence could result in death or serious injury . 1. Do not dismantle or alter the unit. Fire or electric shock could result. 2. Keep the unit away from water or any other liquid. Fire or electric shock c ...

  • Aiphone 834168 C P0811JZ - page 4

    4 SYSTEM CONFIGURA TIONS The IS system is a commercial and security video intercom system especially designed for applications in facilities such as of fi ce buildings, factories, schools, hospitals, and prisons. Installed separately from conventional general-purpose internal communications systems, the IS system can be used as a video door entry ...

  • Aiphone 834168 C P0811JZ - page 5

    5 System con fi guration examples ■ Standard (IP) system The following is an example of standard (IP) system for controlling security and communication for facilities. A site must be con fi gured with an IP-based system. • A standard (IP) system can consist of local systems and IP units. • A local system (Hard wired network system) without ...

  • Aiphone 834168 C P0811JZ - page 6

    6 CONNECTIONS System connection diagram The following is an example of standard (IP) system connection diagram. Refer to page 9 to 26 for details about each unit connection. * IP IS-IPC *1 IS-CCU IS-RCU IS-SCU IS-RS IS-RS IS-RS IS-MV IS-DV/IS-DVF /IS-SS IS-DV/IS-DVF /IS-SS IS-MV PT PT IS-SS IS-PU-UL IS-PU-S IS-PU-UL IS-PU-S IS-PU-UL IS-PU-S IS-PU-U ...

  • Aiphone 834168 C P0811JZ - page 7

    7 IP IP IS-IPC* 1 IS-RCU IS-RS IS-IPMV IS-IPDV /IS-IPDVF IP PT IS-SS IP PS-2420/D/UL/S* 2 PS-2420/D/UL/S* 2 IS-PU-UL IS-PU-S IS-PU-UL IS-PU-S PoE PoE AC transformer Maximum number of each unit connectable to a "local system" and a site of "standard (IP) system" Category Model name T ype Max. number Local system Standard (IP) sys ...

  • Aiphone 834168 C P0811JZ - page 8

    8 Cables Cables and connectors are not included with the products. Refer to page 9 to 26 for details about each unit connection. Notes on cables Pair4 Pair3 12345678 12345678 Pair2 Pair1 T568A Pair4 Pair2 Pair3 Pair1 T568B How to connect or disconnect stranded wires. 8mm (3/8") Notes on CA T5e/6 cables Do not bend the cables to an extent where ...

  • Aiphone 834168 C P0811JZ - page 9

    9 UNIT DET AILS Control unit common information The information on this page is common to Central control unit (IS-CCU), Add-on control unit (IS-SCU), Room sub control unit (IS- * RCU) and IP control unit (IS-IPC). ■ Accessories ・ Mounting bracket × 2 ・ Installation manual (a booklet) *1 × 1 ・ Screw (for wall-mounting) × 4 ・ CD-ROM (In ...

  • Aiphone 834168 C P0811JZ - page 10

    10 Central control unit ( IS-CCU ) ■ Part names NO TE: The illustration of the unit may differ from the actual one. ■ Speci fi cations Central control unit (IS-CCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 800mA Ambient temperature 0 - 40°C (+32°F - +104°F) T alk channels ・ Video channels Local sy ...

  • Aiphone 834168 C P0811JZ - page 11

    11 ■ Connections 1CX1 1CX2 M1 M2 1MX1 1MX2 1MX3 2MX1 2MX2 2MX3 M3 M4 D1 D2 IP1 LAN IP2 IP3 D3 D4 2CX1 2CX2 3CX1 3CX2 4CX1 4CX2 P1 P2 P3 P4 L1 L2 L3 L4 L5 L6 L7 L8 S1 E S2 E S3 E S4 E IS-RCU MASTER ST ATION IS-SCU IS-IPC DC48V DOOR/SUB ST ATION VIDEO/AUDIO P A OUTPUT (600 Ω ) CONT ACT INPUT CHIME INPUT (600 Ω ) ETHERNET VIDEO OUTPUT CONT ACT OUT ...

  • Aiphone 834168 C P0811JZ - page 12

    12 Add-on control unit ( IS-SCU ) ■ Part names NO TE: The illustration of the unit may differ from the actual one. ■ Speci fi cations Add-on control unit (IS-SCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 1.2A Ambient temperature 0 - 40°C (+32°F - +104°F) T alk channels ・ Video channels Local syste ...

  • Aiphone 834168 C P0811JZ - page 13

    13 ■ Connections M1 M2 M3 M4 M5 M6 M7 M8 D1 D2 MX1 MX3 ID 1 2 MX2 D3 D4 D5 D6 D7 D8 P1 P2 P3 P4 L1 L2 L3 L4 MASTER ST ATION IS-CCU DC48V VIDEO/AUDIO DOOR/SUB ST ATION P A OUTPUT (600 Ω ) VIDEO OUTPUT CONT ACT OUTPUT (AC/DC24V 0.5A) V1 V2 CA T5e/6 300m (980') CA T5e/6 300m (980') 15m(50') 200m (650') CA T5e/6 150m (490') ...

  • Aiphone 834168 C P0811JZ - page 14

    14 Room sub control unit ( IS-RCU ) ■ Part names NO TE: The illustration of the unit may differ from the actual one. ■ Speci fi cations Room sub control unit (IS-RCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 1.8A Ambient temperature 0 - 40°C (+32°F - +104°F) T alk channels Local system: 2 talk chann ...

  • Aiphone 834168 C P0811JZ - page 15

    15 ■ Connections C1 C2 CX1/IP1 ID 1 2 3 4 CX2/IP2 C3 C4 C5 C6 C7 C8 C9 C10 C1 1 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 C22 C23 C24 C25 C26 C27 C28 C29 C30 P1 P2 P3 P4 L1 L2 L3 L4 IS-CCU/ IS-IPC DC48V AUDIO DOOR/SUB ST ATION P A OUTPUT (600 Ω ) CONT ACT OUTPUT (AC/DC24V 0.5A) CA T5e/6 300m (980') 15m (50') 200m (650') CA T5e/6 150 ...

  • Aiphone 834168 C P0811JZ - page 16

    16 IP control unit ( IS-IPC ) IP : This unit is needed to connect a local system to a standard (IP) system. ■ Part names NO TE: The illustration of the unit may differ from the actual one. ■ Speci fi cations IP control unit (IS-IPC) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 105mA Ambient temperature 0 ...

  • Aiphone 834168 C P0811JZ - page 17

    17 ■ Connections IP1 IP2 IP3 LAN IS-RCU IS-CCU DC48V ETHERNET CO TELEPHONE 10m (33') 10m (33') 15m (50') 2C IP1 IP2 IP3 φ 0.8-1.2mm (20-16 AWG) IP1 IP2 IP3 IS-RCU IS-CCU CA T5e/6 (x3) 10BASE-T 100BASE-TX 100m (330') CX1/IP1 CX2/IP2 CA T5e/6 (x2) P *3 *1: When connecting a central control unit (IS-CCU) to this unit, connect it ...

  • Aiphone 834168 C P0811JZ - page 18

    18 Color monitor master station (IS-MV) For the part names and their functions, see the OPERA TION MANUAL. * ■ Accessories ・ Mounting bracket × 1 ・ Name card × 1 ・ Desktop stand × 1 ・ Screw (15mm (5/8"), for wall-mounting) × 4 ・ Tie-wrap × 1 ・ Screw (25mm (1"), for gang box) × 4 ・ Name plate × 1 ・ Screw (10mm (7/1 ...

  • Aiphone 834168 C P0811JZ - page 19

    19 When mounting on a desktop stand 30 r 45 r 60 r ■ Connections M V V A A VIDEO OUTPUT AUDIO OUTPUT M1 M4 CA T5e/6 Coax 2C M1 M8 CA T5e/6 P NP NTSC NO TES: Do not use the unoccupied terminals and ports for other purposes. • In order to prev ent miswiring, label both ends of each cable with the unit and terminal names to which they are to be co ...

  • Aiphone 834168 C P0811JZ - page 20

    20 V andal-resistant video door station (IS-DV , IS-DVF), V andal-resistant audio door station (IS-SS) ■ Accessories ・ Screw (for wall-mounting) × 4 (IS-DV only) ・ Special screwdriver × 1 ・ Anchor × 4 (IS-DV only) ・ Back box × 1 (IS-DVF and IS-SS only) ・ T ransparent name plate × 2 (IS-DV and IS-DVF only) ・ China RoHS paper × 1 ...

  • Aiphone 834168 C P0811JZ - page 21

    21 ■ Mounting IS-DV (surface-mount) ABCDEFG IS-DVF ( fl ush-mount), IS-SS ( fl ush-mount) e.g.) IS-DVF Special screwdriver (included) Loosen T ighten V andal-resistant front panel 81 mm (3-1/4'') 194 mm (7-1 1/16'') W ater escape holes Do not block the holes. Ø 6 mm (Ø 1/4") 35 mm (1-3/8") Anchor x 4 (included) S ...

  • Aiphone 834168 C P0811JZ - page 22

    22 ■ Connections (IS-DV and IS-DVF) D NO COM NC PT 300m (980') D1 D4 CA T5e/6 300m (980') D1 D8 CA T5e/6 φ 0.65-1.2mm (22-16 AWG) 10m (33') φ 0.65-1.2mm (22-16 AWG) 10m (33') φ 0.65-1.2mm (22-16 AWG) 10m (33') *1: Output speci fi cations Output method N/O or N/C dry closure contact V oltage between terminals 24V AC, 0 ...

  • Aiphone 834168 C P0811JZ - page 23

    23 ■ Connections (IS-SS) D NC COM NO PT 300m (980') D1 D4 CA T5e/6 300m (980') D1 D8 CA T5e/6 300m (980') C1 C30 CA T5e/6 φ 0.65-1.2mm (22-16 AWG) 10m (33') φ 0.65-1.2mm (22-16 AWG) 10m (33') φ 0.65-1.2mm (22-16 AWG) 10m (33') *1: Output speci fi cations Output method N/O or N/C dry closure contact V oltage betwe ...

  • Aiphone 834168 C P0811JZ - page 24

    24 Room sub station (IS-RS) ■ Accessories ・ Mounting bracket × 1 ・ Screw (for gang box) × 2 ・ Screw (for wall-mounting) × 2 ・ China RoHS paper × 1 ・ Tie-wrap × 1 ■ Mounting <Back wiring> <Surface wiring> When a 1-gang box is not mounted, the cable and wires can be routed to the top of the unit. Cut a cable inlet on th ...

  • Aiphone 834168 C P0811JZ - page 25

    25 ■ Connections C SP SP S SE NO COM P AGING CONT ACT IN CONT ACT OUT 150m (490') D1 D4 CA T5e/6 150m (490') D1 D8 CA T5e/6 150m (490') C1 C30 CA T5e/6 2C 2C P NP 2C φ 0.65-1.2mm (22-16 AWG) 15m (50') φ 0.65-1.2mm (22-16 AWG) 15m (50') φ 0.65-1.2mm (22-16 AWG) 15m (50') *1: Output speci fi cations Output method N ...

  • Aiphone 834168 C P0811JZ - page 26

    26 Power supply unit (IS-PU-UL and IS-PU-S) ■ Accessories ・ AC cord × 1 (included in the package of this power supply unit) ・ Precaution & mounting instruction sheet (paper) × 1 ・ China RoHS paper × 1 (IS-PU-S only) ■ Mounting ■ AC cord requirements T ype: Must comply with requirements set out by the Safety Approval/Certi fi cat ...

  • Aiphone 834168 C P0811JZ - page 27

    27 TECHNICAL DA T A AND PRECAUTIONS T echnical data Operating temperature: • Control unit (IS-CCU, IS-SCU, IS-RCU, IS-IPC), Master station (IS-MV), Room sub station (IS-RS), Power supply unit (IS-PU-UL, IS-PU-S) 0 - 40°C (+32°F - +104°F) Door station (IS-DV , IS-DVF , IS-SS) -10 - 60°C (+14°F - +140°F) Dimensions: • Control unit (IS-CCU, ...

  • Aiphone 834168 C P0811JZ - page 28

    AIPHONE CO., LTD., NAGOYA, JAPAN AIPHONE CORPORATION, BELLEVUE, WA, USA AIPHONE S.A.S., LISSES-EVRY, FRANCE http://www.aiphone.net/ W ARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of two years after delivery to the ultimate user and will repair free of charge or r ...

Производитель Aiphone Категория Intercom System

Документы, которые мы получаем от производителя устройства Aiphone 834168 C P0811JZ мы можем разделить на несколько групп. Это в частности:
- технические чертежи Aiphone
- инструкции обслуживания 834168 C P0811JZ
- паспорта изделия Aiphone
- информационные брошюры
- энергетические этикетки Aiphone 834168 C P0811JZ
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Aiphone 834168 C P0811JZ.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Aiphone 834168 C P0811JZ, инструкции обслуживания, короткие инструкции или инструкции пользователя Aiphone 834168 C P0811JZ. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Aiphone 834168 C P0811JZ.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Aiphone 834168 C P0811JZ, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Aiphone 834168 C P0811JZ пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Aiphone 834168 C P0811JZ.

Полная инструкция обслуживания Aiphone, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Aiphone 834168 C P0811JZ - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Aiphone 834168 C P0811JZ, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Aiphone 834168 C P0811JZ, которое найдем в данном документе
3. Советы по использованию основных функций устройства Aiphone 834168 C P0811JZ - которые должны облегчить нам первые шаги во время использования Aiphone 834168 C P0811JZ
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Aiphone 834168 C P0811JZ
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Aiphone 834168 C P0811JZ в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Aiphone 834168 C P0811JZ?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Aiphone 834168 C P0811JZ, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Aiphone 834168 C P0811JZ со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)