  • Enviro 50-029 - page 1

    SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE This appliance may be installed in an after market permanently located, manufactured (mobile) home, where not prohibited by local codes. Th ...

  • Enviro 50-029 - page 2

    2 FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIR O” HEA TER, PLEASE CAREFULL Y READ THE FOLLO WING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Carefully read all the instructions in this manual rst. Consult the building authority having jurisdiction to determine the nee ...

  • Enviro 50-029 - page 3

    3 Safety Precautions....................................................................................................2 T able of Contents......................................................................................................3 Codes And Approv als...................................................................................... ...

  • Enviro 50-029 - page 4

    4 DIRECT VENT ONLY: This type is identied by the sux DV . This appliance draws all of its air f or combustion from outside the dwelling, through a specially designed v ent pipe system. ** TOP VENT DV ONLY** This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) abov e sea level. In the USA: The applian ...

  • Enviro 50-029 - page 5

    5 Specific a tions D IMENSIONS :                                      ? ...

  • Enviro 50-029 - page 6

    Oper a ting Instructions FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING. L IGHTING I NSTRUCTIONS : 6 CAUT IO N : Hot whil e ope r a t i ng. Do not t ouc h . K e ep chi l dren, cl ot h ing, furni t u re, gas ol ine or o t h e r flam m abl e v a po rs aw ay . F OR YO UR SA F ET Y : D o no t op e ra te t h is f i rep l a ce wi t h the g la ss re mo ...

  • Enviro 50-029 - page 7

    7 Maintenance And Ser vice R OUTINE M AINTENANCE : At least once a year , run through the following procedures to ensure the system is clean and working properly . Check the burner to see if all the ports ar e clear and clean. Check the pilot to make sure it is not blocked by anything. The pi lot ame should be blue with little or no yellow on th ...

  • Enviro 50-029 - page 8

    8 R EPLACING G LASS : The glass in the replace is a high temperatur e ceramic. If the glass is damaged in any way , a factory replacement is required (see P ARTS L IST - C OMPONENTS ). W ear gloves when handling damaged glass door assembly to prevent personal injury . When the glass door assembly is being transported, it must be wrapped in newsp ...

  • Enviro 50-029 - page 9

    Maintenance And Ser vice TO BE INST ALLED BY A QU ALIFIED SERVICE A GENCY ONL Y F UEL C ONVERSION : Warning: This conversion kit shall be installed by a qualied service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructio ...

  • Enviro 50-029 - page 10

    10 1 In accordance with the current CSA B149, Natur al Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFP A 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the r equirements of the gas supplier . t A vent shall not terminate directly above a side w ...

  • Enviro 50-029 - page 11

    11 Initial Inst alla tion V ENT P ARTS : This replace hav e been tested and certied for use with SIMPSON DURA VENT T YPE GS PIPE FOR GAS ST OVES. SELKIRK DIRECT - TEMP SYSTEM SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “MET ALBEST OS MDV VENT SYSTEM” kits are a vailable f or horizontal v enting. When using Simpso ...

  • Enviro 50-029 - page 12

    12 Initial Inst alla tion V ENT R ESTRICTOR S ETTING : 1 2 3 4 5 1 2 3 4 5           15’ (4.57m) 10’ (3.05m) 5’ (1.52m) 2’ (0.62m) 2’ (0.62m) 18” (0.46m) 1 2 3 4 5 V ent Restrictor Setting ...

  • Enviro 50-029 - page 13

    13 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y P LANNING Y OUR I NSTALLATION : When planning your installation, it wil l be necessary to select the proper length of vent pipe for your particular requirements. It is important to note when passing through a wall, the maximum allowable wall thickness is 10 inches (25.4 cm), 1 inches (3.8 cm) ...

  • Enviro 50-029 - page 14

    Initial Inst alla tion QUALIFIED INST ALLERS ONL Y H ORIZONTAL I NSTALLATION : STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance. STEP 2. Direct vent pipe and ttings are d ...

  • Enviro 50-029 - page 15

    15 cap assembly . It is important that the vent pipe extend into the vent cap a sufcient distance with a minimum of 1” (3.2 cm) overlap. Secure the connection between the vent cap pipe and the vent cap by attaching the two sheet metal straps extending from the vent cap assembly into the outer wall of the vent pipe. Use the two sheet metal s ...

  • Enviro 50-029 - page 16

    Initial Inst alla tion 24" (610mm) Maximum Horizontal 24" (610mm) Minimum V ertical Inside Finished Collar W all Thimble Horizontal V ent T ermination Exterior W all Surface Insulation Interior W all Surface If installed on a carpeted surface a hearth is required Interior W all Surface 2.5" (64mm) Inside Finished Collar Horizontal V ...

  • Enviro 50-029 - page 17

    17 STEP 4 . Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up through the Round Support Box. Insure that all pipe and elbow connections are in their fully twist-lock ed position. STEP 5. Cut hole in the roof centered on the small hole placed in the roof from Step 2. The hole should be of sufci ...

  • Enviro 50-029 - page 18

    Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Vertical Termination Storm Collar Flashing Roofing nails Elbow Strap STEP 6. Once the pipe sections have been joined, and run up thr ough the hole in the roof , slip an elbow strap over the exposed sections, bend the support straps outwar ds, and push the elbow strap down to the roof level, as show ...

  • Enviro 50-029 - page 19

    Initial Inst alla tion QUALIFIED INST ALLERS ONL Y F REESTANDING D RAFTHOOD A DAPTOR : This Dr afthood Adaptor is a complete assembly and is ready to t onto your Westport in a vertical vent application only . With the Dr afthood Adaptor correctly installed and wired to the gas control v alve. Y our Direct V ent Fireplace can be vented like a B- ...

  • Enviro 50-029 - page 20

    Initial Inst alla tion GENERAL VENTING INFORMATION: Canadian Installations The venting system must be installed in accordance with the current CSA B149 installation code and/or local codes having jurisdiction. U.S.A. Installations The venting system must be installed in accordance with the current National Fuel Gas Code, ANSI Z223.1, and/or local c ...

  • Enviro 50-029 - page 21

    21 Initial Inst alla tion 4. After a minimum of 10 minutes operation, test the chimney draft with a smoke match at the top row of the pattern to conrm that there is adequate draft or ‘pull’ at the openings around the body of the Drafthood Adaptor , as shown in Figure 26. AUTOMATIC SAFETY SHUT DOWN: If the spil l switch is activated and shuts ...

  • Enviro 50-029 - page 22

    Initial Inst alla tion H EARTH M OUNT I NSTALLATION : This unit may be installed as a hearth mounted unit. Install two 3’ inch pipes up the chimney to a seal plate and cap assembly , one exhaust pipe, and one air intake pipe Using venting manuf actures coaxial to co-linear adapters at the unit and at the chimney termination. Maximum vertical chim ...

  • Enviro 50-029 - page 23

    23 Initial Inst alla tion G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certied exible pipe located on the right side of the unit terminating in a ” male NPT tting. Consult your ...

  • Enviro 50-029 - page 24

    24 Initial Inst alla tion E LECTRICAL R EQUIREMENTS : The ENVIRO ASCO T will operate without electrical power . This model has a millivolt gas control, which uses the pilot ame to generate enough electricity to operate the main burners. The appliance when equipped with an optional blower must be electrically connected and grounded in accordance ...

  • Enviro 50-029 - page 25

    25 Second ar y Inst alla tion I NSTALLATION OF L OG S ET AND E MBERS : Placement pegs for bottom right log. Placement pegs for bottom left log. Ledges for top left log. Ledges for top right log. The placement of the logs is not arbitr ary . If they are positioned incorrectly , the ames can be “pinched” and will not burn correctly . The burne ...

  • Enviro 50-029 - page 26

    26 Second ar y Inst alla tion CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE DOOR REMOVED. Important note: When the unit is turned on for the rst time, It should be turned onto high without the fan on for the rst 4 hours. This will cure the paint, logs, gask et material and the other products used in the manufacturing process. It is advisable ...

  • Enviro 50-029 - page 27

    27 T rouble Shooting Problem Possible Cause Solution Spark will not light the pilot after repeatedly pressing the spark ignitor Defective piezo ignitor . • Check connections to ignitor . • If ignitor connections are good but no spark, replace ignitor . Broken spark electrode. • Check for brok en ceramic insulation, replace electrode if broken ...

  • Enviro 50-029 - page 28

    28 P ar ts List Reference Number Description Part Number 1 120°F (49°C) Ceramic F an T emperature Sensor EC -001 2 S.I.T . Nova V alve NG (50% turn down) EC -006 2 S.I.T . Nova V alve LP (50% turn down) EC -007 3 Thermocouple EC -009 Spark Electrode with Ignitor Cable EC -011 3 Thermopile EC -012 3 Pilot Orice NG Threaded EC -019 3 Pilot Ori? ...

  • Enviro 50-029 - page 29

    Reference Number Description Part Number 14 Dual Convection Blower (no mount) - 115V 50-512 Burner Switch Wiring Harness 50-560 F an Kit Wiring Harness 50-561 15 Electronic Ignition Module 50-589 Dual Bulb Door Gasket (10 ft) 50-634 16 Glass with Gasket 50-715 Hinge pin - silver 50-750 Drafthood Adaptor (Complete) 50-841 Drafthood Adaptor Spill S w ...

  • Enviro 50-029 - page 30

    Reference Number Cast Description Part Number 20 Side panel (left)- Wedgewood Blue 50-064 20 Side panel (left)- Westport Gr een 50-065 20 Side panel (left) - Antique Chestnut 50-857 21 Cast ash shelf - Painted Black 50-066 21 Cast ash shelf - Antique White 50-067 21 Cast ash shelf - Diamond Black 50-068 21 Cast ash shelf - Inferno Red 50-069 21 Cas ...

  • Enviro 50-029 - page 31

    31 P ar ts Diagr am ASCOT - Components December 2004                       ...

  • Enviro 50-029 - page 32

    W arr anty Sherwood Industries Ltd. offers a Limited Lifetime Warr anty on this gas product. This limited lifetime warr anty covers the appliance for a period of seven years from the date of instal lation. This warrant y applies only to the original owner in the original location Covered under the lifetime warr anty are, Surround Panels and Chassis ...

  • Enviro 50-029 - page 33

    33 Inst alla tion Da t a Sheet The following information must be r ecorded by the installer for warr anty purposes and f uture ref erence. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:_____________ ...

Производитель Enviro Категория Indoor Fireplace

Документы, которые мы получаем от производителя устройства Enviro 50-029 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Enviro
- инструкции обслуживания 50-029
- паспорта изделия Enviro
- информационные брошюры
- энергетические этикетки Enviro 50-029
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Enviro 50-029.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Enviro 50-029, инструкции обслуживания, короткие инструкции или инструкции пользователя Enviro 50-029. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Enviro 50-029.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Enviro 50-029, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Enviro 50-029 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Enviro 50-029.

Полная инструкция обслуживания Enviro, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Enviro 50-029 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Enviro 50-029, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Enviro 50-029, которое найдем в данном документе
3. Советы по использованию основных функций устройства Enviro 50-029 - которые должны облегчить нам первые шаги во время использования Enviro 50-029
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Enviro 50-029
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Enviro 50-029 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Enviro 50-029?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Enviro 50-029, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Enviro 50-029 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)