Инструкция обслуживания Philips ISIS iQ UNO

18 страниц 2.97 mb
Скачать

Перейти на страницу of 18

Summary
  • Philips ISIS iQ UNO - page 1

    1 When using electrical products, especially when children are present, basic saf ety precautions should always be follo wed, including the follo wing. READ ALL INSTR UCTIONS BEFORE USING Y OUR PHILIPS A VENT ISIS iQ UNO BREAST PUMP . W ARNING – T o reduce the risk of fire, electr ocution, or other personal injury: • ISIS iQ UNO is intended f o ...

  • Philips ISIS iQ UNO - page 2

    2 All you need to assemble and use ISIS iQ UNO is shown here. If any of the parts are missing, or if you have any questions, please contact Customer Ser vices (see back page f or details). 3 Battery Pack Only the following batteries are compatible w ith the ISIS iQ UNO Battery Pack: Duracell Ultra M3, Duracell Plus, Energizer Ultra Plus, Duracell A ...

  • Philips ISIS iQ UNO - page 3

    4 Please take a f ew minutes to read thr ough this entire instruction leaflet befor e using your Philips A VENT ISIS iQ UNO for the first time. PLEASE SA VE THESE INSTRUCTIONS . Unless advised otherwise by your health pr ofessional it is best to wait until your br eastf eeding routine is established before expr essing – usually around 4 weeks. Co ...

  • Philips ISIS iQ UNO - page 4

    Need Help? Contact Customer Services (see back page for details) 5 Before you use your breast pump f or the first time and every time before use, you must disassemble and clean the par ts as described opposite. Disassembling ISIS iQ UNO 2 1 Disassembly If you ha ve alr eady used your ISIS iQ UNO , turn the pump off by pressing and holding do wn the ...

  • Philips ISIS iQ UNO - page 5

    HELPFUL TIP! The Philips A VENT Electronic, Electric and Micr owa ve Steam Sterilisers are designed to hold the washable components of the ISIS iQ UNO and the entire ISIS Manual Breast Pump . 6 Clean with a damp cloth when necessary: These components DO NO T come into contact with your breast milk. C A UTION: NEVER PUT THE CONTROL HANDLE, BA TTER Y ...

  • Philips ISIS iQ UNO - page 6

    Parts you will need f or steps 1-4: White valve Silicone diaphragm with stem Let-down Massage Cushion White stand Pump body Milk container 7 Before assembling, make sure that your hands ar e clean and you have correctly washed and sterilised the pump (see ‘Cleaning and Sterilising ISIS iQ’ on pag e 6). Also check that none of the pump component ...

  • Philips ISIS iQ UNO - page 7

    Need Help? Contact Customer Services (see back page for details) 8 T o ensure that the pump is completely stable, you can use the stand with the 125ml/4oz milk container. Assembling the pump body of ISIS iQ UNO 2 4 Fit the clear silicone diaphragm with stem into the pump body . Ensure a perfect seal around the rim by pr essing down with your finger ...

  • Philips ISIS iQ UNO - page 8

    Need Help? Contact Customer Services (see back page for details) 9 Parts you will need f or steps 5-7: Batter y pack Mains power lead Assembled pump body (see pages 7-8) Connecting the Electr onics of ISIS iQ UNO 5 Firmly push the control handle onto the pump body so that it sits securely on top of the silicone diaphragm. Control handle 9219-iQUNO_ ...

  • Philips ISIS iQ UNO - page 9

    HELPFUL TIP! Batteries will last for appr oximately 6 hours. The light on the control handle will displa y a continuous RED pulsing flash to warn you when it is time to r eplace them. There will be enough pow er for appro ximately 1 more pumping session, with no drop-off in performance, before the pump s witches itself off. 10 i Connecting the Elec ...

  • Philips ISIS iQ UNO - page 10

    Using a breast pump tak es practice. Y ou ma y need to make se veral attempts befor e you succeed, but because ISIS iQ UNO is so simple and comfortable to use, you will soon get used to expressing milk. 1. Choose a quiet time when you’ re not rushed and unlikel y to be disturbed. 2. Having your baby or a photogra ph of your baby nearby can help e ...

  • Philips ISIS iQ UNO - page 11

    HELPFUL TIP! Before you begin pumping, make sure that you have corr ectly washed, ster ilised and assembled the pump. Consult the ‘Hints to help you succeed’ opposite for tips on stim ulating let-down and milk flow . W ash your hands thoroughly and mak e sure your breasts are clean. Relax in a comf or table chair and lean slightly forwar d so t ...

  • Philips ISIS iQ UNO - page 12

    Need Help? Contact Customer Services (see back page for details) Expressing with ISIS iQ UNO 4 3 Initiate let-down: T o encourage let-down, lightly press the handle in a wa y that feels comfortable and similar to your baby’ s initial rapid suckling action. The petals on the Let-down Massage Cushion will flex in and out around the ar eola, creatin ...

  • Philips ISIS iQ UNO - page 13

    CONSUL T THE GUIDELINES FOR STORING EXPRESSED BREAST MILK ON PA GE 17 5 7 6 Changing or ending your automated pumping session: T o change your pumping rh ythm at any time, press the contr ol button to rev ert to manual control (solid GREEN light) and set a new pattern. T o end your pumping session, press the contr ol button to rev ert to manual con ...

  • Philips ISIS iQ UNO - page 14

    Using your ISIS iQ UNO as a ma n ual breast pump Pump cover Handle ISIS Manual Breast Pump – parts guide Y our ISIS iQ UNO can also be used as a manual pump. In this case, you simply need to r eplace the control handle with the manual handle and pump cover included in a separate bag. p q But this time: p q Assembling your ISIS Manual Br east Pump ...

  • Philips ISIS iQ UNO - page 15

    Need Help? Contact Customer Services (see back page for details) Before you begin pumping, make sure that you have corr ectly washed, sterilised and assembled the ISIS Manual Breast Pump. Consult the ‘Hints to help you succeed’ section on page 11 for tips on stimulating let-down and milk flo w.W ash your hands thoroughly and mak e sure your bre ...

  • Philips ISIS iQ UNO - page 16

    Philips A VENT products ar e interchangeable, so you can expr ess, store and feed with the same container , preserving valuable nutrients that can get lost if breast milk is transfer red. After expressing milk into an A VENT Br east Milk Container , insert a sealing disc into the screw ring and twist onto the container . T o feed, just replace the ...

  • Philips ISIS iQ UNO - page 17

    T echnical Specifications ° Mains Input V oltage 100 - 240 V A C ° Mains Input Frequency 50 - 60 Hz ° Supply voltage fluctuations not exceeding +/- 10% of the nominal voltage ° Ambient T emperature range: +10˚C to +40˚C ° Atmospheric Pressure: 700 to 1060hPa ° Equipment rated for continuous operation ° Maximum speed at maximum vacuum is 60 ...

  • Philips ISIS iQ UNO - page 18

    19 Lack of, or no suction No milk being expressed Pain in the breast area when expressing Milk is drawn up the Let-down Massage Cushion ° Check for any damaged pump parts and replace if necessary . ° Check that all the pump components hav e been assembled correctly and that the white valv e is positioned correctl y . ° Ensure that the silicone d ...

Производитель Philips Категория Breast Pump

Документы, которые мы получаем от производителя устройства Philips ISIS iQ UNO мы можем разделить на несколько групп. Это в частности:
- технические чертежи Philips
- инструкции обслуживания ISIS iQ UNO
- паспорта изделия Philips
- информационные брошюры
- энергетические этикетки Philips ISIS iQ UNO
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Philips ISIS iQ UNO.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Philips ISIS iQ UNO, инструкции обслуживания, короткие инструкции или инструкции пользователя Philips ISIS iQ UNO. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Philips ISIS iQ UNO.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Philips ISIS iQ UNO, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Philips ISIS iQ UNO пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Philips ISIS iQ UNO.

Полная инструкция обслуживания Philips, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Philips ISIS iQ UNO - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Philips ISIS iQ UNO, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Philips ISIS iQ UNO, которое найдем в данном документе
3. Советы по использованию основных функций устройства Philips ISIS iQ UNO - которые должны облегчить нам первые шаги во время использования Philips ISIS iQ UNO
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Philips ISIS iQ UNO
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Philips ISIS iQ UNO в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Philips ISIS iQ UNO?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Philips ISIS iQ UNO, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Philips ISIS iQ UNO со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)