Инструкция обслуживания Faria Instruments GM/ALDL

32 страниц 1.42 mb
Скачать

Перейти на страницу of 32

Summary
  • Faria Instruments GM/ALDL - page 1

    GM ALDL MG2000 ™ T achometer IS0195 rev . A ecr#5576 8/2005 Owner ’ s Manual ...

  • Faria Instruments GM/ALDL - page 2

    IS0195 x7 w/ corrections Mark ups 12/20/05 ...

  • Faria Instruments GM/ALDL - page 3

    Index Figure 1 Default screens page 1 Description page 1 Normal Mode page 2 Contrast and Lighting page 2 Displayed Functions page 3 Default screen 1 page 3 Default screen 2 page 3 Default screen 3 page 3 Default screen 4 page 4 Figure 2 Screen Sequence page 4 Figure 3 LCD Display Screens page 5 Edit Mode page 7 Functions that are adjusted in Edit M ...

  • Faria Instruments GM/ALDL - page 4

    This page lef t blank intentionally . ...

  • Faria Instruments GM/ALDL - page 5

    The F ARIA MG2000 T achometer combines the features of an ECU serial bus gateway and several instruments into one unit: • The tachometer is analog in appearance but driven by a stepper motor for digital accuracy . • The high resolution LCD screen displays information for many other functions and the various “screens” can be configured as t ...

  • Faria Instruments GM/ALDL - page 6

    (see Figure 2). Press the “Mode” button to exit the “screen selection mode” and return to “Normal” mode or do not push any buttons for 4 seconds and the current screen will stay selected and the unit will return to “Normal” mode (see Figure 3). In the “Normal” operation mode, press the “Mode” and “Up” buttons to change t ...

  • Faria Instruments GM/ALDL - page 7

    T o adjust the lighting intensity of all of the instruments in the system, press and hold both the “Down” and “Up” buttons for 2 seconds. The lighting intensity may now be adjusted by using the “Down” or “Up” buttons. Return to t he “ Normal ” mode by pre ssing and holding b oth the “ Down” and “ Up” buttons for 2 s econ ...

  • Faria Instruments GM/ALDL - page 8

    Displays the Engine Hours data received from the engine ECU. Default screen “4” This screen displays fault conditions based on engine data received from the ECU or alarms based on internally set alarm points. Engine alarms from the ECU will be displayed as “Check Engine !” or “Engine Emergency Stop !”. Accessing the “View“ mode when ...

  • Faria Instruments GM/ALDL - page 9

    1. Select Default Screen 2. Reset F uel Used 3. Set Fuel T ank Full 4. Set Amount of F uel 5. Organize User Screens 6. Select Gauge R ange 7. Select Fuel Sender 8. Select Oil Pressure Sender 9. Select Display Units 10. Select Fuel T ank Size 11. F uel T ank Calibrate 12. Low F uel Alarm 13. Software ID and Revision 14. Select Self T est 40 Figure 3 ...

  • Faria Instruments GM/ALDL - page 10

    Pag e 6 This page lef t blank intentionally . ...

  • Faria Instruments GM/ALDL - page 11

    Edit Mode The “Edit” mode is used to adjust or set the values of numerous functions and options in the MG2000. The procedure below specifies the steps to be taken in the “Edit” mode to adjust / set each option. T o enter “Edit” mode, press the “Mode” and “Up” buttons while in “Normal” mode T o return to “Normal” mode, p ...

  • Faria Instruments GM/ALDL - page 12

    1 Display Next Screen 2 3 Press and hold the “Up” and “Down” buttons for 2 seconds to select this screen as the “default screen” and exit. Press “Up” or “Down” to select another screen. Repeat until desired “Default Screen” is selected. Press “Up” or “Down” to select another function or “Mode” to return to “Nor ...

  • Faria Instruments GM/ALDL - page 13

    Set “Amount of Fuel” 1 Set Amount Of Fuel 2 3 NOTE: If a known amount of fuel is in the fuel tank but it is not full, this function can be used to indicate the amount of fuel available. The “Fuel Left” function will then use the amount of fuel entered to calculate the “Fuel Left.” Press and hold the “Up” and “Down” buttons for 2 ...

  • Faria Instruments GM/ALDL - page 14

    Press and hold the “Up” and “Down” buttons for 2 seconds to save selection for Screen 1, line 1 and advance to Screen 1, line 2. Press “Mode” to exit with no change made. Refer to the list of available functions in the owner ʼ s manual. Press and hold “Up” or “Down” to select the number of the function to be displayed in screen ...

  • Faria Instruments GM/ALDL - page 15

    Press and hold the “Up” and “Down” buttons for 2 seconds to select “Oil Pressure Dial.” Press “Up” or “Down” to select another “Gauge Range.” Press “Mode” to return to the “Edit” mode. Press “Up” or “Down” to scroll through the selections. When the correct choice is next to the selection arrow , Press and hol ...

  • Faria Instruments GM/ALDL - page 16

    Select “W ater Press Dial” 1 Select W ater Press Dial 2 3 Press and hold the “Up” and “Down” buttons for 2 seconds to select “W ater Press Dial.” Press “Up” or “Down” to select another “Gauge Range.” Press “Mode” to return to the “Edit” mode. Press “Up” or “Down” to scroll through the selections. When the ...

  • Faria Instruments GM/ALDL - page 17

    Press “Up” or “Down” to scroll through the selections. When the correct choice is next to the selection arrow , Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to the “Edit” mode. 1 > USA 240 – 33 ohm EU 10 – 180 ohm Centroid 2 3 4 5 6 Press “Up” or “Down” to select anothe ...

  • Faria Instruments GM/ALDL - page 18

    Press “Up” or “Down” to scroll through the selections. When the correct choice is next to the selection arrow , Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to select “Units.” 1 > PSI BAR 2 3 Select “V olume Units” 1 Select V olume Units 2 3 Press and hold the “Up” and “D ...

  • Faria Instruments GM/ALDL - page 19

    Press “Up” or “Down” to scroll through the selections. When the correct choice is next to the selection arrow , Press and hold the “Up” and “Down” buttons for 2 seconds to save the selection and return to select “Units.” 1 > Miles kM NM 2 3 Select “Depth Units” 1 Select Depth Units 2 3 Press and hold the “Up” and “D ...

  • Faria Instruments GM/ALDL - page 20

    If there is no tank size available in the list that matches your tank size, scroll to the next screen. 1 Select Other Fuel T ank Size 2 3 4 Press “Up” or “Down” to set the fuel tank size displayed on the screen to match your fuel tank size. Line 4 value will adjust. When set, Press and hold the “Up” and “Down” buttons for 2 seconds ...

  • Faria Instruments GM/ALDL - page 21

    Pag e 1 7 Press and hold the “Up” and “Down” buttons for 2 seconds to save “Full T ank” calibration and exit. Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode. Select “Low Fuel Alarm” setting 1 Low Fuel Alarm 2 3 Press and hold the “Up” and “Down” buttons for 2 seconds to s ...

  • Faria Instruments GM/ALDL - page 22

    This screen will display for 10 seconds. The horn will sound three times. The warning lights will flash three times. The backlights will flash three times. 1 The Self T est Mode Is in Operation 2 3 4 5 6 When “Self T est” is complete the unit will return to the “Edit” mode. Press “Up” or “Down” to select another function or “Mod ...

  • Faria Instruments GM/ALDL - page 23

    Alarm Mode LINE DISPLA Y The “Alarm” screen will appear if a local alarm or an engine alarm occurs. The local alarm is “Low Fuel”. Only two engine alarms appear automatically , “Check Engine” and “Engine Emergency Stop”. Follow the instructions provided to view more information about engine alarms. LOW FUEL Displays “Low Fuel” w ...

  • Faria Instruments GM/ALDL - page 24

    Press and hold “Up” and “Down” for 2 seconds to view alarm messages. Press “Mode” to silence alarm horn and return to “Run” mode. LED will continue to function as stated until engine alarm(s) is no longer sent by ECU. Alarm Messages From the Engine ECU OVER TEMPERA TURE 1 HIGH ENGINE TEMP 2 3 LOW OIL PRESSURE 1 LOW OIL PRESSURE 2 3 ...

  • Faria Instruments GM/ALDL - page 25

    MANIFOLD AIR SENSOR 1 MAN AIR SENSOR SEE DEALER 2 3 THROTTLE POSITION SENSOR 1 TPS F AUL T SEE DEALER 2 3 COOLANT SENSOR 1 COOLANT SENSOR SEE DEALER 2 3 ENGINE ECU CABLE NOT CONNECTED OR NO DA T A 1 NO ENGINE FOUND 2 3 ENGINE EMERGENCY STOP 1 ENGINE EMERGENCY STOP ! 2 3 Alarm Clear Mode LINE DISPLA Y When an alarm condition is corrected or clears, ...

  • Faria Instruments GM/ALDL - page 26

    Pag e 22 MG2000 T achometer 6 5 4 3 2 1 7 8 9 10 1 1 12 1 2 3 6 5 4 ALDL Harness HN0390 ALDL T a chometer Cable 4- pin connector 12- pin connector Pin A Red Pin B White Pin C Green Pin D Black & Sheild Pin 1 Red Pin 2 White Pin 3 Green Pin 4 Black Pin 5 Violet Pin 6 Pink Pin 7 Blue/ Whit e Pin 8 Not Used Pin 9 Not Used Pin 10 Green/ Black Pin 1 ...

  • Faria Instruments GM/ALDL - page 27

    6 5 4 3 2 1 7 8 9 10 1 1 12 1 2 3 6 5 4 MG2000 Speedometer Harness HN0390 Speedometer Cable 1 2 3 4 5 6 7 8 9 10 1 1 12 Wire Jacket 12- pin connector Pin 1 Red Pin 2 White Pin 3 Green Pin 4 Black Pin 5 Not Used Pin 6 T an/ Black Pin 7 T a n Pin 8 Not Used Pin 9 Not Used Pin 10 Not Used Pin 1 1 Not Used Pin 12 Not Used T an/Black T an Not Used Not U ...

  • Faria Instruments GM/ALDL - page 28

    RED - IGNITION MG2000 T achometer 6 5 4 3 2 1 7 8 9 10 1 1 12 1 2 3 6 5 4 NMEA 2000 Harness HN0401 NMEA 0183 Cable 6- pin connector Pin 1 Not Used Pin 2 Not Used Pin 3 Red/ Whit e Pin 4 Red/ Blue Pin 5 Not Used Pin 6 Not Used 4 3 NMEA 0183-A NMEA 0183-B Red/ White Brown* Red (Ignition) White* Y e llow* Green (0183-A) Shield (Ground) Red/ Blue GREEN ...

  • Faria Instruments GM/ALDL - page 29

    T achometer to 2” Gauge Connection PJ0018 Note: T o help reduce moisture in the gauges, be sure to install plug PJ0018 in all open connectors 2" Gauges HN0503 From T achometer 4- pin connector Pin A Red Pin B White Pin C Green Pin D Black & Sheild Pag e 25 ...

  • Faria Instruments GM/ALDL - page 30

    N o tes: ...

  • Faria Instruments GM/ALDL - page 31

    ...

  • Faria Instruments GM/ALDL - page 32

    Copyright 2005 by the Thomas G. Faria Corporation, Uncasville CT . All rights reserved. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the company . Faria® is the trademark of the Thomas G. Faria Corporation ...

Производитель Faria Instruments Категория Automobile Parts

Документы, которые мы получаем от производителя устройства Faria Instruments GM/ALDL мы можем разделить на несколько групп. Это в частности:
- технические чертежи Faria Instruments
- инструкции обслуживания GM/ALDL
- паспорта изделия Faria Instruments
- информационные брошюры
- энергетические этикетки Faria Instruments GM/ALDL
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Faria Instruments GM/ALDL.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Faria Instruments GM/ALDL, инструкции обслуживания, короткие инструкции или инструкции пользователя Faria Instruments GM/ALDL. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Faria Instruments GM/ALDL.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Faria Instruments GM/ALDL, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Faria Instruments GM/ALDL пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Faria Instruments GM/ALDL.

Полная инструкция обслуживания Faria Instruments, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Faria Instruments GM/ALDL - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Faria Instruments GM/ALDL, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Faria Instruments GM/ALDL, которое найдем в данном документе
3. Советы по использованию основных функций устройства Faria Instruments GM/ALDL - которые должны облегчить нам первые шаги во время использования Faria Instruments GM/ALDL
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Faria Instruments GM/ALDL
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Faria Instruments GM/ALDL в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Faria Instruments GM/ALDL?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Faria Instruments GM/ALDL, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Faria Instruments GM/ALDL со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)