Инструкция обслуживания Napoleon Fireplaces GSST8N

16 страниц 1.43 mb
Скачать

Перейти на страницу of 16

Summary
  • Napoleon Fireplaces GSST8N - page 1

    1 W415-0689 / 06.25.08 INST ALLA TION AND OPERA TION INSTRUC TIONS W olf Steel Ltd., 24 Napoleon Rd ., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 ww w .napoleonreplaces .com • ask@napoleon.on.ca CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS: CR97-003 ● CAN-2.21-M85 ● IAS US. 4-96 GSST8N NA TURAL GAS GSST8 ...

  • Napoleon Fireplaces GSST8N - page 2

    2 W415-0689 / 06.25.08 ! W ARNING PG 2-5 INTRODUCTION W arranty General Instructions General Information / Rates and Ef fi ciencies Care of Glass and Plated Parts Dimensions 5-7 INST ALLA TION Gas Installation Electrical Connection Clearance to Combustibles 8-11 FINISHING TMCSS Mounting Cabinet Installation Rain T abs Door Removal Glass Removal TF ...

  • Napoleon Fireplaces GSST8N - page 3

    3 W415-0689 / 06.25.08 NAP OL E ON® products are manuf actured under th e strict Standar d of the world recognized ISO 9001 : 2000 Q uality Assur ance Certifi cate. NAP OL EON ® products are designed with superior components and materials, assembled by train ed cra ftsmen who tak e great pride in their work .  e burn er and valve assembl y ar ...

  • Napoleon Fireplaces GSST8N - page 4

    4 W415-0689 / 06.25.08 THIS GAS APPLIANCE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installation practices vary from region to region and it is important to know the speci fi cs that apply to your area, for example: in Massachusetts State: • The appliance of f valve must be a “T” handle gas cock ...

  • Napoleon Fireplaces GSST8N - page 5

    5 W415-0689 / 06.25.08 FIGURES 1a-c DIMENSIONS Note: All gas connections must be contained within the appliance when complete. 1. The appliance is designed to accept a 1/2” gas supply line. The appliance is equipped with a 1/2” manual shut-off valve. 2. The access to the gas inlet is located in the bottom of the cabinet. 3. The shut of f valve ...

  • Napoleon Fireplaces GSST8N - page 6

    6 W415-0689 / 06.25.08 ! W ARNING CLEARANCES T O COMB USTIBLES MINIMUM CLEARANCES TO COMBUSTIBLES: - 18” to top - 1” to sides - 8” to bottom - 0” to rear Do NOT use the appliance if any part has been under water . Call a quali fi ed service technician IMMEDIA TEL Y to have the appliance inspected for damage to the electrical circuit. IT IS ...

  • Napoleon Fireplaces GSST8N - page 7

    7 W415-0689 / 06.25.08 G G J I K A C D E F H B B INST ALLA TIONS CANADA U.S.A. A 8 INCHES 8 INCHES Clearance above grade, veranda porch, deck or balcony . B 12 INCHES 9 INCHES Clearance to windows or doors that open. C 12 INCHES* 12 INCHES* Clearance to permanently closed windows. D 18 INCHES** 18 INCHES** V ertical clearance to ventilated sof fi ...

  • Napoleon Fireplaces GSST8N - page 8

    8 W415-0689 / 06.25.08 2 MOUNTING BRACKET 4 3 KEYHOLE INSTALLATION TEMPLATE TORCH MOUNTING FRAME CABINET 1 NOTE: It is recommended that all fasteners be stainless steel. 1. Using the installation template (W122-0401) supplied, determine the best mounting location for your new T orch. (refer to your manual for clearances) Mark all 14 hole centres on ...

  • Napoleon Fireplaces GSST8N - page 9

    9 W415-0689 / 06.25.08 RAIN T ABS DOOR REMO V AL GLASS REMO V AL Having removed the door , lay on a smooth fl at surface, face down. There are 4 glass retainers that need to be bent away from the glass to release it from the frame. Do not pry on the glass. When replacing DO NOT SUBSTITUTE MA TERIAL , replace the gasket (W562-0008) and the glass (W ...

  • Napoleon Fireplaces GSST8N - page 10

    10 W415-0689 / 06.25.08 2. Install the trim bracket supplied in your manual baggie to the fi rebox using 3 screws. DOOR CHAIN SLOT FRAME (REAR VIEW) TRIM BRACKET 1/4” ( APPROX.) CONTROL DOOR 1/4” ( APPROX.) With the control door closed, af fi x the logo to the front face of the control door at the bottom left corner . TFSSO FRAME INST ALLA TI ...

  • Napoleon Fireplaces GSST8N - page 11

    11 W415-0689 / 06.25.08 LK8 LIGHT INST ALLA TION (OPTIONAL) 1 . T urn off the electrical and gas supply to the appliance. 2 . Remove the frame from the unit by removing the the 2 stainless steel hex head securing screws from the bottom and lifting the frame off of the top trim bracket. 3 . Lay the frame down on its front, being careful not to scrat ...

  • Napoleon Fireplaces GSST8N - page 12

    12 W415-0689 / 06.25.08 O S A A. This appliance is equipped with an ignition device which automatically lights the burner . Do not try to light by hand. B. Before operating, smell all around the appliance area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor . C. Do not use this appliance if any pa ...

  • Napoleon Fireplaces GSST8N - page 13

    13 W415-0689 / 06.25.08 Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner . The flame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame color to be established. NOTE: It is importan ...

  • Napoleon Fireplaces GSST8N - page 14

    14 W415-0689 / 06.25.08 # P ART NO. DESCRIPTION 1 W225-0223 DOOR FRAME 2* W562-0008 DOOR GASKET 3 W010-1959 GLASS C / W GASKET 4* W300-01 10 GLASS 5 W100-01 1 1 BURNER 6 W357-0006 IGNITOR 7 W190-0026 CONTROL, MODULE 8* W750-0202 WIRE HARNESS 9* W750-0184 IGNITION CABLE 10 W200-0263 IGNITOR COVER 1 1 W200-0262 BURNER COVER 12 W725-0052 NA TURAL GAS ...

  • Napoleon Fireplaces GSST8N - page 15

    15 W415-0689 / 06.25.08 TR OUBLE SHOO TING GUIDE BEFORE A TTEMPTING TO TROUBLESHOOT , PURGE YOUR UNIT AND INITIALL Y LIGHT THE IGNITOR AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED. O S A CERAMIC BODY ELECTRODE HIGH VOL T AGE IGNITION CABLE 1 / 8 ” GAP SENSOR SYMPTOM PROBLEM TEST SOLUTION Electrode sparks, burner ignites, electrode continues to ...

  • Napoleon Fireplaces GSST8N - page 16

    16 W415-0689 / 06.25.08 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS ...

Производитель Napoleon Fireplaces Категория Blowtorch

Документы, которые мы получаем от производителя устройства Napoleon Fireplaces GSST8N мы можем разделить на несколько групп. Это в частности:
- технические чертежи Napoleon Fireplaces
- инструкции обслуживания GSST8N
- паспорта изделия Napoleon Fireplaces
- информационные брошюры
- энергетические этикетки Napoleon Fireplaces GSST8N
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Napoleon Fireplaces GSST8N.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Napoleon Fireplaces GSST8N, инструкции обслуживания, короткие инструкции или инструкции пользователя Napoleon Fireplaces GSST8N. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Napoleon Fireplaces GSST8N.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Napoleon Fireplaces GSST8N, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Napoleon Fireplaces GSST8N пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Napoleon Fireplaces GSST8N.

Полная инструкция обслуживания Napoleon Fireplaces, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Napoleon Fireplaces GSST8N - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Napoleon Fireplaces GSST8N, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Napoleon Fireplaces GSST8N, которое найдем в данном документе
3. Советы по использованию основных функций устройства Napoleon Fireplaces GSST8N - которые должны облегчить нам первые шаги во время использования Napoleon Fireplaces GSST8N
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Napoleon Fireplaces GSST8N
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Napoleon Fireplaces GSST8N в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Napoleon Fireplaces GSST8N?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Napoleon Fireplaces GSST8N, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Napoleon Fireplaces GSST8N со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)