Инструкция обслуживания ICP DAS USA MSM-508FT

27 страниц 0.85 mb
Скачать

Перейти на страницу of 27

Summary
  • ICP DAS USA MSM-508FT - page 1

    April 29, 2008 TM Web Management Us er Manual Industrial Managed Ethernet Switch Version 1.0 This document applied to models of MSM-5 08,MSM-508FC /FCS/FT C o p y r i g h t © I C P D A S C o . , L t d . , A l l R i g h t s R e s e r v e d . ...

  • ICP DAS USA MSM-508FT - page 2

    April 29, 2008 CONTENTS 1. Web Connectio n .......................................................................... 2 2. Basic Setting ............................................................................... 4  Informati on ............ ............ ............ ....... ............ ............ ............ . 4  Network ............ ...

  • ICP DAS USA MSM-508FT - page 3

    April 29, 2008 10. Authentication ..................................... ..................................... 22  Account ........ ............ ............ ........... ........ ............ ............ ......... 22  Accessi ble IP ....................... ............ ....... ............ ............ ........... 2 3  Defaul t Setting ... ...

  • ICP DAS USA MSM-508FT - page 4

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 1  Connection  Basic Setting  Redundant Setting  Port configurat ion  Relay Alarm  Email Alarm  VLAN  QoS  Diagnosis  Authentication Managed S witch W eb Mana gement Op eration This m anual will guide you how to conf igure ICPDAS M ...

  • ICP DAS USA MSM-508FT - page 5

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 2 1. W eb Connection The default net work setting (fac tory default setting) of Manage d Switch is : IP : 192.168.255.1 Mask : 255.255.0.0 Gatewa y : 192.168.0.1 Before access ing Managed Switch thro ugh web bro wser , please m odify above setting to fit your n ...

  • ICP DAS USA MSM-508FT - page 6

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 3 For log in to Web Managem ent, your browser m ust support HTTP authentication. It a llows a web browser t o provid e credentials when m aking a request. ...

  • ICP DAS USA MSM-508FT - page 7

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 4 2. Basic Setting This chapter desc ribes ho w to setting the c omm only inform ation on your Managed Switch.     Information Module Name : : : : Use to specif y the Switch N ame, and als o displa yed as the console prom pt. Max. 8 characte ...

  • ICP DAS USA MSM-508FT - page 8

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 5 Onl y MS Series Switch s upports a real tim e clock . For RS Series S witch, the <Date Ti m e Setting> f unction is inval id.     Network IP Address : : : : IP address is an identifier f or a de vice on a TCP/IP network . It is a 32- ...

  • ICP DAS USA MSM-508FT - page 9

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 6 Mask : : : : The (subnet) M ASK is used to determ ine the subnet of an IP address. Same as th e IP address, a MASK contains four bytes (32 bit s) and it is often ex pressed in the dotted-decim al notation. The fac tory default value is labeled bes ide ...

  • ICP DAS USA MSM-508FT - page 10

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 7 COM1 port is t he RS232 standar d, use for Co nsole Connec tion. Factor y default setti ng is: Baud Rate : 1 15 200 Data Bit : 8 Parity Check : 0 (None) S top Bit : 1 COM2 is the R S485 standard, use f or Modbus com m unication. Factor y default setting is: B ...

  • ICP DAS USA MSM-508FT - page 11

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 8 3. Redund ant Setting Redundant LAN t opolog y is a structur e to provide t he link failure recover y and escaping n etwork loops. It allows you t o setup the re dundant l oops for supporting bac kup connect ions. Managed Switch offers redundanc y options for ...

  • ICP DAS USA MSM-508FT - page 12

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 9     Recovery T i me Setting Recovery Time (C yber-Ring Prot ocol) : : : : Recover y time is the durat ion of conn ections that f rom failure oc curred to retur n to norm al. This f unction allows you to assign the r ecover y time in m illi ...

  • ICP DAS USA MSM-508FT - page 13

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 10 Forward Time (ST P Protocol) : : : : Forward dela y is the durati on tim e that packages from pre- forwarding s tate to forward state. Factory default is 10000ms , the variable is from 4000ms to 3 0000m s (30 sec). Setti ng is only available on STP M ...

  • ICP DAS USA MSM-508FT - page 14

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 1 1 4. Port configuration     Mirror Mirror Port sett ing is comm onl y used to m onitor the network traffic, it can help you to collect and trace abnorm al packets of each port without interrup ting data transm ission. User can specif y a switch p ...

  • ICP DAS USA MSM-508FT - page 15

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 12     T runking This f unction is used for s etting the groups of link aggregation . Port trunk ing allows user to combine m ultiple ph ysical ports into a single l ogical cha nnel. It can inc rease the link speed and provide the bet ter redunda nc ...

  • ICP DAS USA MSM-508FT - page 16

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 13 Port P ort Num ber Speed P ort transm ission speed. ( 10 Mbps / 100 M bps ) Duplex Fl ow Control M ode. Both H alf-duplex an d Full-duplex modes ar e supported. Link P ort Link s tatus. ON : Link is up ; OFF : Link is do wn.     Cable Check ...

  • ICP DAS USA MSM-508FT - page 17

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 14 5. Relay A larm Managed Switch offer a relay contact output on T erminal Block of the Switch equipm ent. It is able to connect to a l ight, bu zzer …etc. warnin g device and notify s ystem f ailures imm ediately . We also offer the web tool to c onfigure t ...

  • ICP DAS USA MSM-508FT - page 18

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 15 6. Email A larm ICPDAS Manag ed Switch c an notify you by email whe n the specif ied event occ urred. This chapter will guide you how to sett ing the related parameter s.     Alarm Event setting User can specif y s y stem and port events that war ...

  • ICP DAS USA MSM-508FT - page 19

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 16     Email Setting User can selec t “Disable A larm Mail” to stop the em ail alarm sending (f actory default). If email alarm is enabled, th ere are two m ethods of em ail report for you select. The firs t one is: warning m ail is sent imm edi ...

  • ICP DAS USA MSM-508FT - page 20

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 17     Email Record Switch Managem ent can k eep the sending date, tim e and status of each w arning em ails. But only the lat est 50 send ing records will be saved. User can click the “Clean R ecord T able” button to de lete all t he email send ...

  • ICP DAS USA MSM-508FT - page 21

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 18 7. VLAN Virtual LANs (VLAN) allows you to setting logical groups of devices, even they are not located on the same physical segment. The logical group called a VLAN, a ll devices be long to the VLAN has the same net work attribute s, and it’s isolated fr o ...

  • ICP DAS USA MSM-508FT - page 22

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 19     Port based VL A Ns In this function , user can de term ine the output ports whic h this input port c an send fr ames to. For example, in above figure, onl y the ingress come fr om Port 4 and Port 8 can be send out from Port 1.     ...

  • ICP DAS USA MSM-508FT - page 23

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 20 8. QoS Quality of Ser vice (QoS) pr ovides diff erent priority to di fferent data flow . It can m ake you to classif y and prioritize data fram es. ICPDAS Manag ed Switch s upport 4 classes of servic es priorit y queues. This f unction allows you to determ i ...

  • ICP DAS USA MSM-508FT - page 24

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 21 IP T oS/DiffServ Enable/Disabl e specified p orts using the TOS (T ype of Service) a nd/or DiffServ (Differentiated Service) f ield in IPv4 fr ame. 802.1p T ag over T os/Diff Serv If <802.1p T ag Priorit y> and <IP T oS/Di ffServ> are both enable ...

  • ICP DAS USA MSM-508FT - page 25

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 22 9. Diagnosis     Ping In this function , user can in put the IP address and cl ick SUMIT button to c heck if the IP is reachable. 10. Authentication     Account There are t wo levels of aut hentication ar e provided i n Switch Ma nage ...

  • ICP DAS USA MSM-508FT - page 26

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 23 At the system initial, the def ault account and password are: Admin and A dmin .     Accessible IP Y ou can set the rem ote IP address here to f ilter the illega l access. O nly the IP address in following table can be allowed to acc ess Manage d ...

  • ICP DAS USA MSM-508FT - page 27

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 24     Default Setting This f unction allows you to clean all sett ings and lo ad the def ault value to S witch Managem ent. Current factor y default val ues are : Netwo rk Setting IP A ddress : 192.168.255.1 Gatewa y : 192.16 8.0.1 Mask : 255.255 ...

Производитель ICP DAS USA Категория Switch

Документы, которые мы получаем от производителя устройства ICP DAS USA MSM-508FT мы можем разделить на несколько групп. Это в частности:
- технические чертежи ICP DAS USA
- инструкции обслуживания MSM-508FT
- паспорта изделия ICP DAS USA
- информационные брошюры
- энергетические этикетки ICP DAS USA MSM-508FT
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания ICP DAS USA MSM-508FT.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа ICP DAS USA MSM-508FT, инструкции обслуживания, короткие инструкции или инструкции пользователя ICP DAS USA MSM-508FT. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия ICP DAS USA MSM-508FT.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства ICP DAS USA MSM-508FT, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании ICP DAS USA MSM-508FT пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей ICP DAS USA MSM-508FT.

Полная инструкция обслуживания ICP DAS USA, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией ICP DAS USA MSM-508FT - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания ICP DAS USA MSM-508FT, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся ICP DAS USA MSM-508FT, которое найдем в данном документе
3. Советы по использованию основных функций устройства ICP DAS USA MSM-508FT - которые должны облегчить нам первые шаги во время использования ICP DAS USA MSM-508FT
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем ICP DAS USA MSM-508FT
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра ICP DAS USA MSM-508FT в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся ICP DAS USA MSM-508FT?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с ICP DAS USA MSM-508FT, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с ICP DAS USA MSM-508FT со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)