    POR T ABLE FORCED AIR HEA TER (WITH BUIL T -IN THERMOST A T) OWNER’S MANUAL IMPORTANT: Read and understand this manual before assembling, start- ing, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. ® Heater Size: 115,000 Btu/Hr Models: B115T , R115T , and REM115T H.S.I. Series ...

  • Desa REM115T - page 2

    2 104193 POR T ABLE FORCED AIR HEA TER 115,000 Btu/Hr H.S.I. Series UNP ACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater . SAFETY INFORMA TION Carbon Monoxide Poisoning: Early signs of carbon mo ...

  • Desa REM115T - page 3

    3 104193 OWNER’S MANUAL Figure 1 - Portable Forced Air Heater PRODUCT IDENTIFICA TION ASSEMBL Y These models are furnished with wheels and a front handle. Some models are furnished with a rear handle also. Wheels, handle(s), and the mounting hardware are found in the shipping carton. TOOLS NEEDED • Medium Phillips Screwdriver • 3/8" Open ...

  • Desa REM115T - page 4

    4 104193 POR T ABLE FORCED AIR HEA TER 115,000 Btu/Hr H.S.I. Series Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels will result in a clogged fuel filter and/or nozzle. IMPORTANT: Use a KEROSENE ONLY storage container. Be sure storage container is clean. Foreign matter such as rust, dirt, or water will cause the ign ...

  • Desa REM115T - page 5

    5 104193 OWNER’S MANUAL TO START HEATER 1. Follow all ventilation and safety infor- mation. 2. Fill fuel tank with kerosene or No. 1 fuel oil. 3. Attach fuel cap. 4. T urn thermostat knob clockwise to the HIGH position. 5. Plug power cord of heater into three- prong, grounded extension cord. Exten- sion cord must be at least six feet long. Extens ...

  • Desa REM115T - page 6

    6 104193 POR T ABLE FORCED AIR HEA TER 115,000 Btu/Hr H.S.I. Series TROUBLESHOOTING WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. OBSERVED FAULT Motor does not start five seconds after heater is plugged in Motor starts and runs but heater does not ignite Heater ignites but igni ...

  • Desa REM115T - page 7

    7 104193 OWNER’S MANUAL Figure 7 - Pressure Gauge Plug Removal Fan Motor Figure 6 - Air Output, Air Intake, and Lint Filters Flush Setscrew Motor Shaft Figure 5 - Fan Cross Section SER VICE PROCEDURES WARNING: Never service heater while it is plugged in, op- erating, or hot. Severe burns and electrical shock can occur. UPPER SHELL REMOVAL 1 . Rem ...

  • Desa REM115T - page 8

    8 104193 POR T ABLE FORCED AIR HEA TER 115,000 Btu/Hr H.S.I. Series Figure 9 - Fuel Filter Removal SER VICE PROCEDURES Continued FUEL FILTER 1. Remove side cover screws using 5/16" nut-driver . 2. Remove side cover . 3. Pull upper fuel line off fuel filter neck. 4. Carefully pry bushing, fuel filter , and lower fuel line out of fuel tank. 5. ...

  • Desa REM115T - page 9

    9 104193 OWNER’S MANUAL SER VICE PROCEDURES Continued Figure 12 - Removing Air and Fuel Line Hoses Nozzle/ Adapter Assembly Combustion Chamber Figure 13 - Removing Nozzle/Adapter Assembly Nozzle Face Nozzle Nozzle Seal Nozzle Adapter Air Line Fitting Fuel Line Fitting Figure 14 - Nozzle and Nozzle Adapter NOZZLE ASSEMBLY 1. Remove upper shell (se ...

  • Desa REM115T - page 10

    10 104193 POR T ABLE FORCED AIR HEA TER 115,000 Btu/Hr H.S.I. Series SER VICE PROCEDURES Continued Sandpaper .003"/.004" Gap Measured With Feeler Gauge Blade Rotor Gap Adjusting Screw Gap Adjusting Screw Insert Rotor Air Output Filter Blade Pump Plate Air Intake Filter Filter End Cover Fan Guard Figure 16 - Rotor Location Figure 17 - Gap ...

  • Desa REM115T - page 11

    11 104193 OWNER’S MANUAL TECHNICAL SER VICE You may have further questions about op- eration or troubleshooting. If so, contact DESA International’s Technical Service Dept. at 1-800-323-5190. You can also visit DESA International’s Technical Service web site at www.desatech.com . SPECIFICA TIONS Output Rating (Btu/Hr) 1 15,000 Fuel Use Only K ...

  • Desa REM115T - page 12

    12 104193 POR T ABLE FORCED AIR HEA TER 115,000 Btu/Hr H.S.I. Series 1 2 3 23 19 9 10 16 11 12 15 25 26 27 24 28 29 20 22 21 30 31 17 14 14 33 34 35 36 32 26 13 18 5 4 6 7 8 7-2 7-1 7-5 7-4 7-3 40 39 38 ILLUSTRA TED PA R T S BREAKDOWN B115T R115T REM115T Motor and Pump Assembly 10-11 10-13 10-17 10-16 10-15 10-14 10-13 10-12 10-10 10-1 10-2 10-3 10 ...

  • Desa REM115T - page 13

    13 104193 OWNER’S MANUAL P AR TS LIST B115T R115T REM115T This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. ** See OPTIONAL ACCESSORIES *** Not available as an assembly. KEY PART NO ...

  • Desa REM115T - page 14

    14 104193 POR T ABLE FORCED AIR HEA TER 115,000 Btu/Hr H.S.I. Series 1 2 3 4 WHEELS AND HANDLE PARTS LIST KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 HA2203 Handle 2 (if equipped) 2 M12345-33 Screw, #10-24 x 1 3 / 4 " (B115T) 8 (REM115T, R115T) 6 3 M12342-3 Wheel Support Frame 1 4 NTC-3C Hex Nut, #10-24 (B115T) 8 (REM115T, R115T) 6 5 097896-04 ...

  • Desa REM115T - page 15

    15 104193 OWNER’S MANUAL REPLACEMENT PA R T S Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Techni- cal Service Dept. at 1-800-32 ...

  • Desa REM115T - page 16

    W ARRANTY AND REP AIR SER VICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA International will repair or replace the heater without cha ...

Производитель Desa Категория Electric Heater

Документы, которые мы получаем от производителя устройства Desa REM115T мы можем разделить на несколько групп. Это в частности:
- технические чертежи Desa
- инструкции обслуживания REM115T
- паспорта изделия Desa
- информационные брошюры
- энергетические этикетки Desa REM115T
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Desa REM115T.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Desa REM115T, инструкции обслуживания, короткие инструкции или инструкции пользователя Desa REM115T. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Desa REM115T.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Desa REM115T, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Desa REM115T пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Desa REM115T.

Полная инструкция обслуживания Desa, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Desa REM115T - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Desa REM115T, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Desa REM115T, которое найдем в данном документе
3. Советы по использованию основных функций устройства Desa REM115T - которые должны облегчить нам первые шаги во время использования Desa REM115T
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Desa REM115T
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Desa REM115T в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Desa REM115T?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Desa REM115T, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Desa REM115T со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)