  • ATEN Technology CS-1732 - page 1

    User Manual CS-1732 CS-1734 2003-07-17 ...

  • ATEN Technology CS-1732 - page 2

    NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Subpart J of Part 15 of the FCC Rules. Th ese limits are designed to provide reasonable protection against harmful interf erence in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, i ...

  • ATEN Technology CS-1732 - page 3

    Packing List The complete Master View CS-1732 / CS-1734 package consists of: M 1 CS-1732 or CS-1734 KVM Switch M 2 CS Custom KVM Cables (CS-1732) M 4 CS Custom KVM Cables (CS-1734) M 1 Firmware Upgrade Cable M 1 User Manual M 1 Quick Start Guide Check to make sure that all the components are present and that nothing was damaged in shipping. If you ...

  • ATEN Technology CS-1732 - page 4

    Contents Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Hardware Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • ATEN Technology CS-1732 - page 5

    Overview The Master View CS-1732 and CS-1734 represent a revolutionary new direction in KVM (Keyboard, Video, Mouse) Switches. The CS-1732 and CS-1734 are dual function two and four Port KVM Switches combined with 2 Port USB Hubs. As KVM switches, they allow users to access two and four computers from a single USB keyboard, USB mouse, and monitor c ...

  • ATEN Technology CS-1732 - page 6

    Features M Dual function KVM-USB switch M One console controls 2 (CS-1732 ) or 4 (CS-1734 ) computers and two additional USB devices M Dual interface support - PS/2 or USB keyboard and mouse dat a transport* M Independent (asynchronous) switching of KVM and peripheral USB ports M Fully compliant with the USB 1.1 specificat ion - supports transf er ...

  • ATEN Technology CS-1732 - page 7

    Hardware Requirements Console M A VGA, SVGA, or Mult isync monitor capable of the highest resolut ion that you will be using on any computer in the installation. M A USB style mouse M A USB style keyboard Computer The following equipment must be installed on each computer: M A VGA, SVGA or Multisync card. M Type A USB port. Cables Only CS Custom ca ...

  • ATEN Technology CS-1732 - page 8

    Introduction CS-1732 Front View 1. Port Selection Switches M Press a switch to access the computer attached to its corresponding port . M Pressing Buttons 1 and 2 simultaneously for 2 seconds starts Auto Scan Mode . See p. 14 for details. 2. Port LEDs The Port LEDs are built into the Port Selection Swit ches. The upper ones are the KVM Port LEDs; t ...

  • ATEN Technology CS-1732 - page 9

    CS-1734 Front View 1. Port Selection Switches M Press a switch to access the computer attached to its corresponding port . M Pressing Buttons 1 and 2 simultaneously for 2 seconds performs a keyboard and mouse reset. M Pressing Buttons 3 and 4 simultaneously for 2 seconds starts Auto Scan Mode . See p. 14 for details. 2. Port LEDs The Port LEDs are ...

  • ATEN Technology CS-1732 - page 10

    CS-1732 / CS-1734 Rear View 1 3 2 6 4 56 1 3 2 6 4 56 2003-07-17 6 CS-1732 / CS-1734 User Manual ...

  • ATEN Technology CS-1732 - page 11

    1. Console Audio Jacks The cables from your microphone and speakers plug in here. Each jack is marked with an appropriate icon to indicate itself. 2. USB Peripheral Section USB peripherals (printers, scanners, etc. ) can plug into any available port . 3. Firmware Upgrade Section M Firmware Upgrade Recovery Switch During normal operation and while p ...

  • ATEN Technology CS-1732 - page 12

    Installation Before you Begin Cable Connection To set up your Master View CS-1732 / CS-1734 installation, ref er to the installation diagrams on the following pages, and do the following: 1. Plug your USB keyboard and USB mouse into the USB Ports located on the unit’s front panel. 2. Plug your monitor into the Console monitor port located on the ...

  • ATEN Technology CS-1732 - page 13

    2003-07-17 CS-1732 / CS-1734 User Manual 9 ...

  • ATEN Technology CS-1732 - page 14

    USB Cable Connection: PS/2 Cable Connection: 2003-07-17 10 CS-1732 / CS-1734 User Manual ...

  • ATEN Technology CS-1732 - page 15

    Operation Hot Plugging The Master View CS-1732 / CS-1734 supports USB hot plugging - components can be removed and added back into the installation by unplugging their cables from the CPU ports without the need to shut the unit down. Powering Off and Restarting If it becomes necessary to Power Off the Mast er View unit, before starting it back up y ...

  • ATEN Technology CS-1732 - page 16

    Hotkey Operation The CS-1732 / CS-1734 provides an extensive, easy-to-use, hotkey funct ion that makes it convenient to control and configure your KVM inst allat ion from the keyboard. All hotkey operations with the exception of Skip Mode (see p. ) begin by invoking Hotkey Mode. Invoking Hotkey Mode To invoke Hotkey Mode, do the following: 1. Press ...

  • ATEN Technology CS-1732 - page 17

    Hotkey Port Access Hotkey Port Access allows you to select which computer has the KVM focus and/or which computer has access to the USB peripherals. Note: CPU Port selection and USB Port assignment can be done independently (asynchronously). One computer can have the KVM focus while another has access to the USB peripherals. The CS-1732 / CS-1734 p ...

  • ATEN Technology CS-1732 - page 18

    M Auto Scan Mode The CS-1732 / CS-1734’s Auto Scan feature automatically cycles through the computer ports at regular 5 second intervals. This allows you to monit or the computer activity without having to take the trouble of swit ching from port to port manually. To start Auto Scan Mode: 1. Invoke HKM (see p. 12) 2. Press and release the A key O ...

  • ATEN Technology CS-1732 - page 19

    Alternate Hotkey Invocation Keys An alternate set of Hotkey Invocat ion keys is provided in case the def ault set conflicts with programs running on the computers. To switch to the alternate Hotkey Invocation set , do the following: 1. Invoke HKM (see p. 12) 2. Press and release the H key The Hotkey Invocation keys become the Ctrl key (instead of N ...

  • ATEN Technology CS-1732 - page 20

    Hotkey Configuration The CS-1732 / CS-1734’s default port configuration is for a PC Compatible keyboard operating platform, and a US English keyboard language code. If your requirements call for different port settings (you have a Mac or Sun attached to a port, e.g.), you can change them by bringing the KVM focus to the port and using the hotkey ...

  • ATEN Technology CS-1732 - page 21

    Keyboard Emulation Sun Keyboard The PS/2 (101/104) key keyboard can emulate the functions of the Sun keyboard when the Control key [Ctrl] is used in conjunction with ot her keys. The corresponding functions are shown in the table below. Note: When using [Ctrl] combinatons, press and release the Ctrl key, then press and release the activation key. P ...

  • ATEN Technology CS-1732 - page 22

    Mac Keyboard The keyboard emulation mappings from the Mac keyboard to the PS/2 keyboards (101 key and 104 key), are listed in the table below. Note: When using key combinatons, press and release the first key (Ct rl or Alt), then press and release the activation key. PS/2 Mac Keyboard [Shift] Shi ft [Ctrl] Ctrl [Win] [Ctrl] [1] [Ctrl] [2] [Ctrl] [3 ...

  • ATEN Technology CS-1732 - page 23

    The Firmware Upgrade Utility The Windows-based Firmware Upgrade Utility (FWUpgrade.exe) provides a smooth, automated process for upgrading the KVM switch’s firmware. The Utility comes as part of a Firmware Upgrade Package that is specif ic for each device. New firmware upgrade packages are posted on our web site as new firmware revisions become a ...

  • ATEN Technology CS-1732 - page 24

    Starting the Upgrade To upgrade your firmware: 1. Run the downloaded Firmware Upgrade Package file - either by double clicking the file icon, or by opening a command line and entering the full path to it. The Firmware Upgrade Utility Welcome screen appears: 2. Read and Agree to the License Agreement (enable the I Agree radio button). 2003-07-17 20 ...

  • ATEN Technology CS-1732 - page 25

    3. Click Next to continue. The Firmware Upgrade Utility main screen appears: The Utility inspects your installation. All the devices capable of being upgraded by the package are listed in the Device List panel. 4. As you select a device in the list, its description appears in the Device Description panel. 2003-07-17 CS-1732 / CS-1734 User Manual 21 ...

  • ATEN Technology CS-1732 - page 26

    5. After you have made your device selection(s), Click Next to perform the upgrade. If you enabled Check Firmware Version , the Utility compares the device’s firmware level with that of the upgrade files. If it finds that the device’s version is higher than the upgrade version, it brings up a dialog box informing you of the situation and gives ...

  • ATEN Technology CS-1732 - page 27

    Upgrade Succeeded After the upgrade has completed, a screen appears to inform you that the procedure was successful: Click Finish to close the Firmware Upgrade Utility. 2003-07-17 CS-1732 / CS-1734 User Manual 23 ...

  • ATEN Technology CS-1732 - page 28

    Upgrade Failed If the upgrade failed to complete successfully a dialog box appears asking if you want to retry. Click Yes to retry. If you Click No , the Upgrade Failed screen appears: Click Cancel to close the Firmware Upgrade Utility. See the next sect ion, Firmware Upgrade Recovery , for how to proceed. 2003-07-17 24 CS-1732 / CS-1734 User Manua ...

  • ATEN Technology CS-1732 - page 29

    Firmware Upgrade Recovery There are basically three conditions that call for firmware upgrade recovery: M When you begin a firmware upgrade, but decide not to proceed with it. M When the Mainboard firmware upgrade fails. M When the I/O firmware upgrade fails. To perform a firmware upgrade recovery, do the following: 1. Slide the Firmware Upgrade Re ...

  • ATEN Technology CS-1732 - page 30

    Appendix Troubleshooting Symptom Possible Cause Action Erratic behavior. Unit not recei ving enough power. Use a DC 5V power adapter if you are not already using one. If y ou are already using a power adapter, check that it matc hes the system specificati ons (DC 5V), and that it i s plugged in and functi oning properly. Keyboard and/or Mouse not r ...

  • ATEN Technology CS-1732 - page 31

    Specifications Function CS-1732 CS-1734 Computer Connections 2 4 CPU Port Sel ection Front Panel Swi tches; Hotkey USB Port S election Hotkey LEDs On Line 2 (Orange) 4 (Orange) USB Link 2 (Green) 4 (Green) Console Connectors Keyboard 1 x USB Type A Mouse 1 x USB Ty pe A Video 1 x HDB -15 female Audio 1 x Stereo port 1 x Microphone port CPU Connecto ...

  • ATEN Technology CS-1732 - page 32

    Limited Warranty IN NO EVENT SHALL THE DIRECT VENDO R’S LI ABI LITY EXCEED THE PRICE PAID FOR THE PRODUCT FROM THE DI RECT , INDI RECT , SPECIAL, INCIDENTAL OR CONSEQUENT IAL DAMAG ES RESULTING FRO M THE USE OF THE PRODUCT, DISK OR ITS DOCUMENTAT ION. The direct vendor makes no warranty or representation, expressed, implied, or statutory with res ...

Производитель ATEN Technology Категория Switch

Документы, которые мы получаем от производителя устройства ATEN Technology CS-1732 мы можем разделить на несколько групп. Это в частности:
- технические чертежи ATEN Technology
- инструкции обслуживания CS-1732
- паспорта изделия ATEN Technology
- информационные брошюры
- энергетические этикетки ATEN Technology CS-1732
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания ATEN Technology CS-1732.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа ATEN Technology CS-1732, инструкции обслуживания, короткие инструкции или инструкции пользователя ATEN Technology CS-1732. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия ATEN Technology CS-1732.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства ATEN Technology CS-1732, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании ATEN Technology CS-1732 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей ATEN Technology CS-1732.

Полная инструкция обслуживания ATEN Technology, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией ATEN Technology CS-1732 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания ATEN Technology CS-1732, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся ATEN Technology CS-1732, которое найдем в данном документе
3. Советы по использованию основных функций устройства ATEN Technology CS-1732 - которые должны облегчить нам первые шаги во время использования ATEN Technology CS-1732
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем ATEN Technology CS-1732
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра ATEN Technology CS-1732 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся ATEN Technology CS-1732?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с ATEN Technology CS-1732, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с ATEN Technology CS-1732 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)