    A.C. Wire-in Single and/or Multiple Station (up to 24 Devices) Ionization Smoke Alarm with 9 V olt Battery Back Up and HUSH TM Control to temporar- ily silence nuisance alarms. Thank you for purchasing this smoke alarm. It is an important part of your family’ s home safety plan. Y ou can trust this product to pr ovide the highest quality safety p ...

  • Kidde i12060A - page 2

    This alarm detects products of combustion using the ionization technique. It contains 0.9 microcurie of Americium 241, a radioactive material (see Section 9). Distributed under U.S. NRC License No. 32-23858-01E. Manufactured in compli- ance with U.S. NRC safety criteria in 10 CFR 32.27. The purchaser is exempt from any r egulatory requirements. Do ...

  • Kidde i12060A - page 3

    FIGURE 1 FIGURE 2 FIGURE 3 • Locate an alarm in every room wher e someone sleeps with the door closed. The closed door may prevent an alarm not located in that r oom from waking the sleeper . • Smoke, heat, and combustion products rise to the ceiling and spr ead horizon- tally . Mounting the smoke alarm on the ceiling in the center of the room ...

  • Kidde i12060A - page 4

    MOBILE HOME INST ALLA TION Modern mobile homes have been designed and built to be energy efficient. Install smoke alarms as recommended above (r efer to RECOMMENDED LOCA- TIONS and FIGURES 1 and 2). In older mobile homes that are not well insulated compar ed to present stan- dards, extr eme heat or cold can be transferred from the outside to the in ...

  • Kidde i12060A - page 5

    3. INST ALLA TION INSTRUCTIONS WIRING REQUIREMENTS • This smoke alarm should be installed on a U.L. listed or recognized junction box. All connections should be made by a qualified electrician and all wiring used shall be in accordance with articles 210 and 300.3(B) of the U.S. National Electrical Code ANSI/NFP A 70, NFP A 72 and/or any other cod ...

  • Kidde i12060A - page 6

    • For more information about compatible inter connect units and their function- ality in an interconnect system, visit our web site at: www .Kidde.com • The maximum wire run distance between the first and last unit in an inter con- nected system is 1000 feet. • Figure 4 illustrates inter connection wiring. Improper connection will result in d ...

  • Kidde i12060A - page 7

    OF W ALL MOUNTED SMOKE ALARMS WILL DECREASE OPERA TIONAL EFFECTIVENESS. 1. Remove the trim ring from the back of the alarm by holding the trim ring and twisting the alarm counter -clockwise. 2. After selecting the proper smoke alarm location as described in Section 1 and wiring the AC Quick Connector as described in the WIRING INSTRUCTIONS, attach ...

  • Kidde i12060A - page 8

    CAUTION: Due to the loudness (85 decibels) of the alarm, always stand an arms length away from the unit when testing. 8. T ur n on the AC power . The green Power On Indicator should be lit when the alarm is operating from AC power . Confirm unit operation by pressing the T est/Hush button. T AMPER RESIST FEA TURES Smoke Alarm T amper Resist Feature ...

  • Kidde i12060A - page 9

    arrow . (see Figure 9) The tamper resist featur e is now active and the battery carrier can not be opened until the tamper resist featur e is deactivated. NOTE: Before activating the battery carrier tamper r esist feature, make sur e a fresh battery is installed in the unit and that the battery carrier is properly closed. If the battery carrier tam ...

  • Kidde i12060A - page 10

    LED INDICA TORS: This smoke alarm is equipped with red and green LED indica- tors. The green LED (when illuminated) indicates the pr esence of AC power . The red LED has four modes of operation: Standby Condition: The red LED will flash every 40 seconds to indicate that the smoke alarm is operating properly . Alarm Condition: When the alarm senses ...

  • Kidde i12060A - page 11

    5. NUISANCE ALARMS Smoke alarms are designed to minimize nuisance alarms. Cigar ette smoke will not normally set off the alarm, unless the smoke is blown dir ectly into the alarm. Combustion particles from cooking may set of f the alarm if the alarm is located close to the cooking area. Large quantities of combustible particles ar e generat- ed fro ...

  • Kidde i12060A - page 12

    This smoke alarm uses a 9V carbon zinc battery (alkaline and lithium batteries may also be used). A fresh battery should last for one year under normal operat- ing conditions. This alarm has a low/missing battery monitor circuit which will cause the alarm to “chirp” approximately every 30-40 seconds for a minimum of seven (7) days when the batt ...

  • Kidde i12060A - page 13

    CLEANING YOUR ALARM YOUR ALARM SHOULD BE CLEANED A T LEAST ONCE A YEAR T o clean your alarm, remove it from the mounting bracket as outlined in the beginning of this section. Y ou can clean the interior of your alarm (sensing chamber) by using compressed air or a vacuum cleaner hose and blowing or vacuuming through the openings ar ound the perimete ...

  • Kidde i12060A - page 14

    • Smoke alarms cannot provide an alarm if smoke does not r each the alarm. Therefor e, smoke alarms may not sense fires starting in chimneys, walls, on roofs, on the other side of a closed door or on a dif ferent floor . • If the alarm is located outside the bedroom or on a dif ferent floor , it may not wake up a sound sleeper . • The use of ...

  • Kidde i12060A - page 15

    WHA T TO DO WHEN THE ALARM SOUNDS • Alert small children in the home. • Leave immediately by your escape plan. Every second counts, so don’t waste time getting dressed or picking up valuables. • In leaving, don’t open any inside door without first feeling its surface. If hot, or if you see smoke seeping through cracks, don’ t open that ...

  • Kidde i12060A - page 16

    10. NFP A REQUIRED PROTECTION The National Fire Pr otection Association’ s Standard 72 provides the following information: Smoke Detection – Where r equired by applicable laws, codes, or standards for the specified occupancy , approved single- and multiple-station smoke alarms shall be installed as follows: (1) In all sleeping rooms Exception: ...

  • Kidde i12060A - page 17

    12. SERVICE AND WARRANTY If after reviewing this manual you feel that your smoke alarm is defective in any way , do not tamper with the unit. Return it for servicing to: KIDDE, 1016 Corporate Park Dr ., Mebane, NC 27302. 1-800-880-6788 (See W arranty for in-warranty returns). 1260-7205-01(820-0394G-EN)_v1.qxd:_ 2011.5.16 10:15 AM Page 17 ...

  • Kidde i12060A - page 18

    TEN YEAR LIMITED W ARRANTY Kidde warrants to the original purchaser that the enclosed smoke alarm (but not the battery) will be free fr om defects in material and workmanship or design under normal use and service for a period of ten years from the date of pur chase. The obligation of Kidde under this warranty is limited to repairing or replacing t ...

Производитель Kidde Категория Smoke Alarm

Документы, которые мы получаем от производителя устройства Kidde i12060A мы можем разделить на несколько групп. Это в частности:
- технические чертежи Kidde
- инструкции обслуживания i12060A
- паспорта изделия Kidde
- информационные брошюры
- энергетические этикетки Kidde i12060A
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Kidde i12060A.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Kidde i12060A, инструкции обслуживания, короткие инструкции или инструкции пользователя Kidde i12060A. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Kidde i12060A.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Kidde i12060A, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Kidde i12060A пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Kidde i12060A.

Полная инструкция обслуживания Kidde, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Kidde i12060A - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Kidde i12060A, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Kidde i12060A, которое найдем в данном документе
3. Советы по использованию основных функций устройства Kidde i12060A - которые должны облегчить нам первые шаги во время использования Kidde i12060A
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Kidde i12060A
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Kidde i12060A в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Kidde i12060A?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Kidde i12060A, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Kidde i12060A со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)