    Operating Manual VX-800 VERTEX STANDARD CO., LTD. 4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan VERTEX STANDARD US Headquarters 17210 Edwards Rd., Cerritos, CA 90703, U.S.A. International Division 8350 N.W. 52nd Terrace, Suite 201, Miami, FL 33166, U.S.A. YAESU EUROPE B.V. P.O. Box 75525, 1118 ZN Schiphol, The Netherlands YAESU UK LTD. Unit 12 ...

  • Vertex Standard VX-800 - page 2

    Contents Controls & Connectors ...................................................................................................................................................... 1 Before You Begin ................................................................................................................................................. ...

  • Vertex Standard VX-800 - page 3

    VX-800 O PERA TING M ANUAL 1 C ONTROLS & C ONNECT ORS ...

  • Vertex Standard VX-800 - page 4

    VX-800 O PERA TING M ANUAL 2 B EFORE Y OU B EGIN Battery Pack Installation and Removal r To install the batter y, hold the transceiver with your left hand, so your palm is over the speaker and your thumb is on the top of the belt clip. In- sert the battery pack into the battery compartment on the back of the radio while tilting the Belt Clip outwar ...

  • Vertex Standard VX-800 - page 5

    VX-800 O PERA TING M ANUAL 3 O PERA TION Preliminary Steps r Install a charged battery pack onto the transceiver, as described previousl y. r Screw the supplied an- tenna onto the Antenna jack. Never attempt to op- erate this transceiver without an antenna con- nected. r If you have a Speaker/Mi- crophone, we recommend that it not be connected unti ...

  • Vertex Standard VX-800 - page 6

    VX-800 O PERA TING M ANUAL 4 is selected by the channe selector knob. For further details, contact your dealer. . r Rotate the VOL/ PWR knob to set the volume level. If no signal is present, press and hold in the Moni- tor button (the center button on the left side) more than 2 seconds; background noise will now be heard, and you may use this to se ...

  • Vertex Standard VX-800 - page 7

    VX-800 O PERA TING M ANUAL 5 O PERA TION r Press the top panel’s SEL1/SEL2 key to activate one of the preprogrammed func- tions which may have been enabled at the time of programming by the dealer. Similarl y, when using the 16-key version, the [ A ], [ B ], [ C ], and [ D ] function keys activate one of these functions, if programmed by the deal ...

  • Vertex Standard VX-800 - page 8

    VX-800 O PERA TING M ANUAL 6 A DV ANCED O PERA TION Soft Key and T oggle Switch Functions The VX-800 includes the [ SEL1 ], [ SEL2 ], [ MON ], and [ LAMP ] Keys, and the Toggle Switch, while the 16-key version additionally provides [ A ], [ B ], [ C ], [ D ] function Keys. The Soft key and Toggle Switch functions can be customized, via program- min ...

  • Vertex Standard VX-800 - page 9

    VX-800 O PERA TING M ANUAL 7 A DV ANCED O PERA TION None Channel Scan Dual Watch High/Low Power T alk Around TX Save Disable LCD Invert Encryption Disable* Follow-Me DW Call/Reset* Speed Dial* Emergency* Group Up Group Down Channel Up Channel Down Monitor Lamp SEL2 MON LAMP A B C D SEL1 Soft Key Functions * requires DTMF/Encryption Unit ...

  • Vertex Standard VX-800 - page 10

    VX-800 O PERA TING M ANUAL 8 A DV ANCED O PERA TION Description of Operating Functions Channel Scan The Scanning feature is used to monitor multiple signals programmed into the transceiver. While scanning, the transceiver will check each channel for the presence of a signal, and will stop on a chan- nel if a signal is present. One key or switch may ...

  • Vertex Standard VX-800 - page 11

    VX-800 O PERA TING M ANUAL 9 TX Save Disable Press the assigned Soft key or switch the Toggle Switch to the assigned position to disable the Trans- mit Battery Saver, if you are operating in a loca- tion where high power is almost always needed. The Transmit Battery Saver helps extend battery life by reducing transmit power when a very strong signa ...

  • Vertex Standard VX-800 - page 12

    VX-800 O PERA TING M ANUAL 10 A DV ANCED O PERA TION Encryption Disable Press the assigned Soft key or switch the Toggle Switch to the assigned position to turn off the op- tional voice encryption unit temporaril y , for use when an incorrect setting of (or failure in) the encryption system at one end of the communica- tion path has made it impossi ...

  • Vertex Standard VX-800 - page 13

    VX-800 O PERA TING M ANUAL 11 previously) pass through more than one Group during the scanning process (normall y , scanning is performed within the current group only). To include the current Group in the scanning loop, press and hold in the assigned Soft key for one second. To remove a Group from Group Scan, press and hold in the assigned Soft ke ...

  • Vertex Standard VX-800 - page 14

    VX-800 O PERA TING M ANUAL 12 When you delete a Group or channel, “-SKIP-” will appear on the LCD for one second after press- ing the Soft ke y . To restore a particular channel to your scanning list, press and hold in the Soft key again for one second; “-STOP-” will appear on the LCD for one second after pressing the Soft ke y. Call/Reset ...

  • Vertex Standard VX-800 - page 15

    VX-800 O PERA TING M ANUAL 13 A DV ANCED O PERA TION ARTS (Auto Range Transpond System) This system is designed to inform you when you and another ARTS-equipped station are within commu- nication range. During ARTS operation, your radio automatically transmits for about 1 second every 25 seconds (the interval is programmed by the Dealer) in an atte ...

  • Vertex Standard VX-800 - page 16

    VX-800 O PERA TING M ANUAL 14 U NDERST ANDING R ADIO W A VES Radio waves travel from one point to another by sev- eral different means. The general term for these meth- ods of wave travel is “propagation”. You may know that “shortwave” signals can be propagated over dis- tances of several thousand miles by reflection off of the upper region ...

  • Vertex Standard VX-800 - page 17

    VX-800 O PERA TING M ANUAL 15 S PECIFICA TIONS (T YPE USA) G ENERAL VX-800 ( VHF ) VX-800 ( UHF ) Frequency Range : 134-160, 148-174 MHz 450-485 MHz Number of Channels : 200 channels 200 channels Channel Spacing : 12.5/25/30 kHz 12.5/25/30 kHz Battery Voltage : 7.4 VDC 7.4 VDC Temperature Range : –30°C to +60°C –30°C to +60°C Frequency Stab ...

  • Vertex Standard VX-800 - page 18

    VX-800 O PERA TING M ANUAL 16 This device complies with Part 15 of the FCC rules. Operation is subject to the condition that this device does not cause harmful interference. Availability of accessories may vary; some accessories are supplied as standard per local requirements, others may be unavailable in some reqions. Check with your V ertex Stand ...

  • Vertex Standard VX-800 - page 19

    This device complies with Part 15 of the FCC rules. Op- eration is subject to the condition that this device does not cause harmful interference. ...

  • Vertex Standard VX-800 - page 20

    Copyright 2001 VERTEX STANDARD CO., LTD. All rights reserved. No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO., LTD. Printed in Japan E 126775 00 ...

Производитель Vertex Standard Категория Two-Way Radio

Документы, которые мы получаем от производителя устройства Vertex Standard VX-800 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Vertex Standard
- инструкции обслуживания VX-800
- паспорта изделия Vertex Standard
- информационные брошюры
- энергетические этикетки Vertex Standard VX-800
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Vertex Standard VX-800.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Vertex Standard VX-800, инструкции обслуживания, короткие инструкции или инструкции пользователя Vertex Standard VX-800. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Vertex Standard VX-800.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Vertex Standard VX-800, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Vertex Standard VX-800 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Vertex Standard VX-800.

Полная инструкция обслуживания Vertex Standard, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Vertex Standard VX-800 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Vertex Standard VX-800, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Vertex Standard VX-800, которое найдем в данном документе
3. Советы по использованию основных функций устройства Vertex Standard VX-800 - которые должны облегчить нам первые шаги во время использования Vertex Standard VX-800
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Vertex Standard VX-800
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Vertex Standard VX-800 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Vertex Standard VX-800?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Vertex Standard VX-800, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Vertex Standard VX-800 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)