  • Graham Field 14423-8 - page 1

    14423-2 / 14423-4 / 14423-8 UL TRASOUND POCKE T DOPPLER USER MANUAL 14423-INS-LAB-RevD11 Impor tant: Do not use the Pocket Doppler without rst reading and understanding this manual! Save this manual for future use.  FederalLaw(USA)restrictsthisdevicetosale byorontheorderofaphysician.Thisprodu ...

  • Graham Field 14423-8 - page 2

    14423-INS-LAB-RevD1 1 2 CONTENTS 1 INTRODUCTION .........................................................................3 INTENDEDUSEOFTHISDEVICE ........................................ 3 INCLUDEDFEA TURES .......................................................... 3 OPTIONALACCESSORIES ......................... ...

  • Graham Field 14423-8 - page 3

    14423-INS-LAB-RevD1 1 3 1 INTR ODUCTION This user manual contains important information and safety pr ecautions for the Grafco Ultrasound Pocket Dop- pler . Before using the Pocket Doppler , please r ead and understand this entir e user manual. T ake special note of all safety pr ecautions that begin “W ARNING” and “CAUTION”. Save thi ...

  • Graham Field 14423-8 - page 4

    14423-INS-LAB-RevD1 1 4 OPTIONALA CCESSORIES The following accessories for use with the Grafco Ultrason- ic Pocket Doppler ar e available from your GF Health Pr od- ucts, Inc. authorized distributor or www .grahameld.com. ItemNo. ProductDescription 4001GF Coupling Gel, case of 12 0.25 liter bottles 4002GF Coupling Gel, 5 liter bot ...

  • Graham Field 14423-8 - page 5

    14423-INS-LAB-RevD1 1 5 2 SAFETYINFORMA TION SafetyGuidance This unit has internally powered equipment, and the degree of shock protection is type B T ype B protection means that this product is in accordance with permitted leakage currents and dielectric strengths of IEC 60601-1. SAFETYPRECA UTIONS The safety statements pr esented i ...

  • Graham Field 14423-8 - page 6

    14423-INS-LAB-RevD1 1 6 WARNINGS  W ARNING:FederalLaw(USA)restrictsthisdeviceto salebyorontheorderofaphysician.Thisproduct shouldnotbeusedunlesstheoperatorhasbeenin- structedbyaqualiedhealthcareprofessional.  W ARNING:Donotuset ...

  • Graham Field 14423-8 - page 7

    14423-INS-LAB-RevD1 1 7  W ARNING:DonottheusePocketDopplerifthebat- terycoverisopen.  W ARNING:UseonlythoseprobesprovidedbyGF HealthProducts,Inc.intendedtobeusedwiththe GrafcoPocketDoppler .  W ARNING:Donotstretchtheprobecable? ...

  • Graham Field 14423-8 - page 8

    14423-INS-LAB-RevD1 1 8 NO TICES s  NOTICE:ThemainunitoftheGrafcoPocketDoppler isdesignedforcontinuousnormaloperation.Donot immerseorsubmergeinanyliquid. s  NOTICE:KeepthePocketDoppleranditsenviron- mentcleananddust-free.Protectthedevic ...

  • Graham Field 14423-8 - page 9

    14423-INS-LAB-RevD1 1 9 SYMBOLS Attention: Refer to accompanying documents (this manual). This item is compliant with Medical Device Directive 93/42/ EEC of June 14, 1993, a directive of the European Economic Community . This symbol consisting of two parts, see below . Indicates that the equipment should be disposed of according to local regulat ...

  • Graham Field 14423-8 - page 10

    14423-INS-LAB-RevD1 1 10 3 HANDLING GFHEAL THPRODUCTS,INC.FREIGHTPOLICY F ory ourpr otection,readcar efull y The carrier accepted this mer chandise “in good condition” and is r esponsible for safe deliver y . Before signing the fr eight bill, inspect the shipment carefully for damage or missing pieces. Appar ent ...

  • Graham Field 14423-8 - page 11

    14423-INS-LAB-RevD1 1 1 1 Inspection Check the Pocket Doppler for nicks, dents, scratches, me- chanical or other damage. Check all the cables and acces- sories. ST ORAGE Stor e the repackaged Pocket Doppler in a dry area. s  NOTICE:EnsurethatthetemperatureatthePocket Doppler'slocationduringstoragedoes? ...

  • Graham Field 14423-8 - page 12

    14423-INS-LAB-RevD1 1 12 4 UL TRASOUNDPOCKETDOPPLER ANDA CCESSORIES APPEARANCEANDFEA TURES The following gur es illustrate the Pocket Doppler with the 2.0 MHz water-resistant pr obe, and accompanying tables describe labeled featur es. F rontPanel F ea tur e Function Display Panel Displays system info System status L ...

  • Graham Field 14423-8 - page 13

    14423-INS-LAB-RevD1 1 13 Pow e r  Button T urns the Ultrasound Pocket Doppler ON or OFF Probe Sock et The probe connects here to the Ultrasound Pocket Doppler Jack Denition 1 Power Supply 2 Signal 3 Probe Coding 1 4 Probe Coding 2 5 Probe Coding 3 6 (Shell) GND ...

  • Graham Field 14423-8 - page 14

    14423-INS-LAB-RevD1 1 14 R earPanel F ea tur e Function P ock etClip Attachment Attaches Pocket Doppler to pocket Batter y Compar tment Opens to install/replace battery ProbeFrame Attaches probe to Pocket Doppler ...

  • Graham Field 14423-8 - page 15

    14423-INS-LAB-RevD1 1 15 To p Panel F ea tur e Function Sock et Name Picture Function Charge Socket Not used Earphone Socket Connect earphone Signal Interface 1 GND 2 Signal 3 Signal 4 Signal 5 Signal War ning Refer to accompanying documents (this user manual)  W ARNING: Accessoryequipmentconnectedtothe analoganddig ...

  • Graham Field 14423-8 - page 16

    14423-INS-LAB-RevD1 1 16 LeftPanel F ea tur e Function V olumeControl Adjust volume Increase volume: Rotate volume knob clockwise Decrease volume: Rotate volume knob counter-clockwise MODEButton Not used ST ART/ST OPButton REC/PLA YButton ...

  • Graham Field 14423-8 - page 17

    14423-INS-LAB-RevD1 1 17 POCKETDOPPLERWA TER-RESIST ANTPR OBES The 2.0 MHz, 4.0 MHz, and 8.0 MHz water-resistant pr obes connect to the main unit of the Grafco Pocket Doppler via the pr obe socket. The following table lists and describes the main information on each pr obe's label in or der of ap- pearance: P ock etDopplerWa ...

  • Graham Field 14423-8 - page 18

    14423-INS-LAB-RevD1 1 18 5 SETUP INST ALLING  OR  REPLACING  THE  B A TTER Y  W ARNING:EnsurethatPocketDopplerpowerisoff beforereplacingthebattery .  W ARNING:Install/replacethebatteryatleast6feet (1.5meters)fromthepatient.  W ARNING:Useonly9V? ...

  • Graham Field 14423-8 - page 19

    14423-INS-LAB-RevD1 1 19 s  NOTICE:Ifthebatteryterminalsbecomedirty ,wipe themwithaclean,dryclothbeforeusingthePocket Doppler . s  NOTICE:Batterieshavelifecycles.Ifthebatteryuse timeshortensnoticeably ,thebattery'slifecycleis over ...

  • Graham Field 14423-8 - page 20

    14423-INS-LAB-RevD1 1 20 6 OPERA TION PROBEOPERA TION R emo vingtheProbefr omthePoc k etDoppler s  NOTICE:Donotdragordroptheprobe.Donotdis- connecttheprobefromthePocketDoppler . 1. The pr obe is installed in Pocket Doppler probe frame (left pictur e above). Hold the Po ...

  • Graham Field 14423-8 - page 21

    14423-INS-LAB-RevD1 1 21 SwappingProbes s  NOTICE:Donotdragordroptheprobeortheprobe connector . The Pocket Doppler is shipped with one pr obe connected. T o replace the connected pr obe with another Pocket Dop- pler pr obe: 1. Follow steps 1-3 in pr evious section, Removing the Pr obe fr om the Pocket Doppl ...

  • Graham Field 14423-8 - page 22

    14423-INS-LAB-RevD1 1 22 FET ALHEART(FH)MONIT ORING FHMonitoringwith2.0MHzWa ter-R esistantProbe Refer to pictur e at right. The au- dio fetal heart beat is sent out via the built-in speaker or attached earphone. 1. Palpate for the fetus position to nd the best location to place the pr obe and hear the fetal heart r ...

  • Graham Field 14423-8 - page 23

    14423-INS-LAB-RevD1 1 23 V ASCULAR  MONIT ORING  WITH  4.0  OR  8.0  MHZ  PROBE  (OPTIONAL) The 4.0 MHz and 8.0 MHz pr obes can be used to perform vascular monitoring assessment of blood ow . The 8.0 MHz pr obe is used for more supercial evaluation than the 4.0 MHz pr obe. Refer to the following probe site illustrat ...

  • Graham Field 14423-8 - page 24

    14423-INS-LAB-RevD1 1 24 1. Apply a liberal amount of gel on the site to be exam- ined. 2. Place the pr obe so that the head is at least at 45º to the vessel to be examined. 3. Adjust the position of the pr obe to obtain the loudest audio signal. For best r esults, keep the probe as still as possible once the optimum position is located. 4. Adj ...

  • Graham Field 14423-8 - page 25

    14423-INS-LAB-RevD1 1 25 7 MAINTENANCE  W ARNING:Failureonthepartoftheresponsiblefacil- ityemployingtheuseofthisequipmenttoimplement asatisfactorymaintenanceschedulemaycauseun- dueequipmentfailureandpossiblehealthhazard. MAINTENANCE  W ARNING:Befor ...

  • Graham Field 14423-8 - page 26

    14423-INS-LAB-RevD1 1 26 s  NOTICE:KeepthePocketDoppleranditsenviron- mentcleananddust-free.Protectthedevicefromvi- bration,corrosivemedicine,andhightemperatures. s  NOTICE:Donotusehigh-temperaturesterilizingpro- cess,lowtemperaturesteam,E-beam,and ...

  • Graham Field 14423-8 - page 27

    14423-INS-LAB-RevD1 1 27 CleaningtheP ock etDopplerPr obe s  NOTICE:Donotallowliquidtoentertheultrasound system. s  NOTICE:Donotpourliquidsontheprobewhile cleaning. The Pocket Doppler pr obe’ s acoustic surface is fragile and must be handled with car e. 1. T o prolong the ...

  • Graham Field 14423-8 - page 28

    14423-INS-LAB-RevD1 1 28 DISINFECTION DisinfectingtheP ock etDopplerPr obe s  NOTICE:Donotallowanyliquidtoentertheprobe socketwhiledisinfectingorimmersingtheprobe. 1. Clean the exterior surface of the pr obe as recommend- ed in the pr evious section. 2. T o disinfect the probe, immer ...

  • Graham Field 14423-8 - page 29

    14423-INS-LAB-RevD1 1 29 8 SPECIFICA TIONS ModelNumber andName 14423-2 Ultrasonic Pocket Doppler with 2.0 MHz probe 14423-4 Ultrasonic Pocket Doppler with 4.0 MHz probe 14423-8 Ultrasonic Pocket Doppler with 8.0 MHz probe Safety Complies with: EN 60601-1/1990 Classication Anti-electric Shock T ype Internally powered equipment Anti ...

  • Graham Field 14423-8 - page 30

    14423-INS-LAB-RevD1 1 30 Physical Characteristics Size (Width x Depth x Height) 3.35 x 1.26 x 5.43 inches (85 x 32 x 138 mm) Weight (including a battery and a probe) .64 lb (290 ±5g) En vironment Working T emperature 41°F ~ 104°F (5°C ~ 40°C) Humidity ≤80% RH Atmospheric Pressure 12.47 ~ 15.37 psi (86 ~ 106 kPa) T ransport and Storage ...

  • Graham Field 14423-8 - page 31

    14423-INS-LAB-RevD1 1 31 Ultrasound Nominal Frequency 2.0 MHz W ater-Resistant Probe 2.0 MHz 4.0 MHz W ater-Resistant V ascular Probe 4.0 MHz 8.0 MHz W ater-Resistant V ascular Probe 8.0 MHz Working Frequency 2.0 MHz W ater-Resistant Probe 2.0 MHz ±10% 4.0 MHz W ater-Resistant V ascular Probe 4.0 MHz ±10% 8.0 MHz W ater-Resistant V ascular Pro ...

  • Graham Field 14423-8 - page 32

    14423-INS-LAB-RevD1 1 32 9 LIMITEDWARRANTY GF Health Products Inc. warrants this pr oduct to be fr ee fr om manufacturing defects in material and workmanship for its period of warranty that is in accor dance with industr y standar ds. This warranty is extended only to the original pur chaser/consumer or dealer/non-consumer of this new pr o ...

  • Graham Field 14423-8 - page 33

    14423-INS-LAB-RevD1 1 33 pur chaser’ s cost, for warranty inspection using the serial number as identication (or , if the product is not serialized, lot number and date code) within thirty (30) days of return authorization issue date. In the event you do not receive sat- isf act or y war ran ty service , plea se cont act GF Heal th Prod uct ...

  • Graham Field 14423-8 - page 34

    14423-INS-LAB-RevD1 1 34 Thi s war rant y giv es you spec ic lega l righ ts and you may also have other legal rights which var y fr om state to state (pr ov- ince to province). Some states (pr ovinces) do not allow the ex clu sio n or limi tat io n of inci de nta l or con seq uen tia l dama ge, or limitation on how long an implied warranty la ...

  • Graham Field 14423-8 - page 35

    14423-INS-LAB-RevD1 1 35 10 APPENDIXA,ECDECLARA TIONOF CONFORMITY ECDec lar ationof Confor mity Manufactured for GF Health Products, Inc., 2935 Northeast Parkway , Atlanta, GA 30360 Product Ultrasound Pocket Doppler Classication (MDD, Annex IX): IIa We herewith declare that the above mentioned product(s) meet the tr ...

  • Graham Field 14423-8 - page 36

    14423-INS-LAB-RevD1 1 36 11 APPENDIXB ,EMCINFORMA TION GUID ANCEANDMANUF ACTURER’S DECLARA TION Electroma gneticEmissions—forallEquipment andSystems Guidanceandmanufacturer’sdec lar ation— electroma gneticemission The Grafco Ultrasound Pocket Doppler is intended for use in the electromagnet ...

  • Graham Field 14423-8 - page 37

    14423-INS-LAB-RevD1 1 37 Electroma gneticImmunity—forallEquipment andSystems thatarenotLife-Suppor ting Guidanceandmanufacturer’sdec lar ation— electroma gneticimmunity The Grafco Ultrasound Pocket Doppler System is intended for use in the electromagnetic environment specied below . Do not use the sys ...

  • Graham Field 14423-8 - page 38

    14423-INS-LAB-RevD1 1 38 Info 1: At 80 MHz and 800 MHz, the higher frequency range applies. Info 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reection from struc- tures, objects and people. a: Field strengths from xed transmitters, such as base stations for radio (cellular/c ...

  • Graham Field 14423-8 - page 39

    14423-INS-LAB-RevD1 1 39 For transmitters rated at a maximum output power not listed previously , the recommended separation distances in meters (m) can be estimated using the equation applicable to the frequency of the transmitter , where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufactu ...

  • Graham Field 14423-8 - page 40

    14423-INS-LAB-RevD1 1 40 12 APPENDIX  C,  O VERALL  SENSITIVITY Ov er allSensitivity(2MHzProbe) Diameter of T arget Reector (mm) Distance (d) (mm) Reflection Loss A (d) T wo-way Attenuation B=∑B a +B w ∑B a (T :mm B a :dB) B w (dB) B (dB) 1.58 A=45.7dB @2 MHz 50 45.7 T 20 4.8 4.0 - 0 57.6 Ba 40 9.6 8.0 - 75 45.7 T ...

  • Graham Field 14423-8 - page 41

    14423-INS-LAB-RevD1 1 41 Ov er allSensitivity(2MHzProbe) Diameter of T arget Reector (mm) V n (r .m.s.) mV V n (r .m.s.) mV dB Overall Sensitivity (S=A(d)+B+C) dB 1.58 A=45.7dB @2 MHz 186 94 5.93 109.2 175 90 5.78 107.8 174 89 5.82 107.9 173 90 5.68 100.9 2.38 A=43.2dB @2 MHz 178 89 6.02 1 10.0 170 90 5.52 107.1 165 85 5.76 105.3 ...

  • Graham Field 14423-8 - page 42

    14423-INS-LAB-RevD1 1 42 13 INDEX A Accessories, optional 4 Accessory equipment, certica- tion of 6 Address, Graham-Field 34 Appendix A, EC Declaration of Conformity 35 Appendix B, EMC information 36 Appendix C, Overall Sensitivity 40 B Battery , installing / r eplacing 18 Battery terminals, cleaning 19 C CAUTION statement, signicance 5 ...

  • Graham Field 14423-8 - page 43

    14423-INS-LAB-RevD1 1 43 T T elephone number , Graham-Field 34 T op panel features and illustra- tion 15 U User manual, contents of 3 V V olume control 16 W WARNING statement, signi- cance 5 W arranty , limited 32 ...

  • Graham Field 14423-8 - page 44

    USA Corporate Headquar ters: GF Health Products, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 telephone: 770-368-4700 www .grahamfield.com 14423-INS-LAB-RevD11 © 2011 GF Health Products, Inc. ...

Производитель Graham Field Категория SONAR

Документы, которые мы получаем от производителя устройства Graham Field 14423-8 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Graham Field
- инструкции обслуживания 14423-8
- паспорта изделия Graham Field
- информационные брошюры
- энергетические этикетки Graham Field 14423-8
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Graham Field 14423-8.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Graham Field 14423-8, инструкции обслуживания, короткие инструкции или инструкции пользователя Graham Field 14423-8. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Graham Field 14423-8.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Graham Field 14423-8, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Graham Field 14423-8 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Graham Field 14423-8.

Полная инструкция обслуживания Graham Field, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Graham Field 14423-8 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Graham Field 14423-8, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Graham Field 14423-8, которое найдем в данном документе
3. Советы по использованию основных функций устройства Graham Field 14423-8 - которые должны облегчить нам первые шаги во время использования Graham Field 14423-8
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Graham Field 14423-8
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Graham Field 14423-8 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Graham Field 14423-8?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Graham Field 14423-8, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Graham Field 14423-8 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)